Greisinger GPHU 014 MP/BNC pH Measurement Converter Instruction Manual

Model: GPHU 014 MP/BNC

1. Pengenalan

This manual provides comprehensive instructions for the safe and efficient operation of your Greisinger GPHU 014 MP/BNC pH Measurement Converter. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage. Keep this manual for future reference.

The GPHU 014 MP/BNC is designed to convert pH electrode signals into a standardized output, allowing for precise pH monitoring in various applications. It is intended for use with compatible pH electrodes featuring a BNC connector.

2. Maklumat Keselamatan

  • Always operate the device within its specified environmental conditions.
  • Jangan dedahkan peranti kepada suhu yang melampau, cahaya matahari langsung atau kelembapan yang tinggi.
  • Elakkan daripada menjatuhkan atau meletakkan peranti kepada kesan yang kuat.
  • Ensure proper electrical connections are made according to the instructions to prevent electrical shock or damage.
  • Jangan cuba membuka atau membaiki peranti sendiri. Rujuk semua servis kepada kakitangan yang berkelayakan.
  • Use only compatible pH electrodes and accessories with this converter.
  • Dispose of the device and any associated components in accordance with local environmental regulations.

3. Kandungan Pakej

Sila semak kandungan bungkusan setelah diterima. Jika terdapat barang yang hilang atau rosak, hubungi pembekal anda dengan segera.

  • Greisinger GPHU 014 MP/BNC pH Measurement Converter
  • Manual Arahan (dokumen ini)
  • Mounting accessories (if applicable, check packaging)

Note: A pH electrode is not included with this converter and must be purchased separately.

4. Produk Lebihview

The Greisinger GPHU 014 MP/BNC is a compact and robust pH measurement converter designed for industrial and laboratory applications. It features a clear digital display and intuitive controls for easy operation.

Greisinger GPHU 014 MP/BNC pH Measurement Converter front view

Rajah 1: Depan view of the Greisinger GPHU 014 MP/BNC pH Measurement Converter. The display shows "7.46 pH" and includes "ATC" and "Temp" indicators. Below the display are three buttons labeled "SET 1", "▼ 2", and "▲ 3". A BNC connector is visible on the right side for electrode connection. Two small ports are visible at the bottom.

Greisinger GPHU 014 MP/BNC pH Measurement Converter side view

Rajah 2: sebelah view of the Greisinger GPHU 014 MP/BNC pH Measurement Converter, highlighting the BNC connector and the robust housing. The connector is labeled "AMPHENOL".

Komponen Utama:

  • Paparan Digital: Shows pH value, temperature, and status indicators.
  • SET Button (1): Digunakan untuk memasukkan dan mengesahkan tetapan.
  • Down Button (2): Used to navigate menus and decrease values.
  • Up Button (3): Used to navigate menus and increase values.
  • Penyambung BNC: For connecting a compatible pH electrode.
  • Input Kuasa: (Location not visible in images, refer to device for exact position)

5. Persediaan

5.1. Pemasangan

The converter can be mounted using the integrated mounting points (screws visible in Figure 1). Ensure the mounting location is stable, free from excessive vibration, and within the specified operating temperature range.

5.2. Connecting the pH Electrode

  1. Ensure the converter is powered off.
  2. Carefully connect your pH electrode's BNC connector to the BNC input on the right side of the GPHU 014 MP/BNC converter (refer to Figure 1 and 2).
  3. Ensure the connection is secure but do not overtighten.

5.3. Sambungan Kuasa

Connect the appropriate power supply to the converter. Refer to the device labeling for specific voltage and current requirements. Ensure the power source is stable and matches the device's specifications.

5.4. Penentukuran Awal

Before first use, or after prolonged storage, the pH converter and electrode system must be calibrated. Refer to your pH electrode's manual for specific calibration buffer requirements.

  1. Hidupkan peranti.
  2. Access the calibration menu using the SET button. (Specific steps may vary, consult the device's on-screen prompts or a more detailed technical manual if available).
  3. Follow the on-screen instructions to perform a 2-point or 3-point calibration using standard pH buffer solutions (e.g., pH 4.01, 7.00, 10.01).
  4. Rinse the electrode thoroughly with distilled water between buffer solutions.
  5. Confirm calibration settings.

6. Beroperasi

6.1. Mengambil Pengukuran

  1. Ensure the pH electrode is properly connected and calibrated.
  2. Immerse the pH electrode into the sample solution, ensuring the sensing bulb and reference junction are fully submerged.
  3. Allow sufficient time for the reading to stabilize on the digital display. The display will show the current pH value.
  4. Note any temperature readings if the electrode has an integrated temperature sensor and ATC (Automatic Temperature Compensation) is active.

6.2. Navigasi Menu

The SET, ▼, and ▲ buttons are used to navigate through the device's menu options. Press SET to enter the menu or confirm a selection. Use ▼ and ▲ to scroll through options or adjust values.

  • SET (1): Enter/Exit menu, confirm selection.
  • ▼ (2): Scroll down, decrease value.
  • ▲ (3): Scroll up, increase value.

Specific menu functions (e.g., setting alarm limits, output configuration) will be detailed in a more advanced technical manual or on-screen prompts.

7. Penyelenggaraan

7.1. Cleaning the Converter

Wipe the exterior of the converter with a soft, damp kain. Jangan gunakan pembersih atau pelarut yang kasar. Pastikan tiada cecair memasuki peranti.

7.2. Penyelenggaraan Elektrod pH

Proper maintenance of the pH electrode is crucial for accurate readings and extended lifespan. Refer to your specific pH electrode's instruction manual for detailed care instructions. General guidelines include:

  • Always keep the electrode's sensing bulb hydrated, typically in a storage solution or pH 7 buffer. Never store dry.
  • Rinse the electrode with distilled or deionized water after each measurement.
  • Clean the electrode regularly to remove sample residues. Specific cleaning solutions may be required depending on the application.
  • Recalibrate the electrode regularly, especially if readings become unstable or inaccurate.

7.3. Penyimpanan

When not in use for extended periods, store the converter in a clean, dry environment at room temperature. Ensure the pH electrode is properly stored according to its manufacturer's recommendations.

8. Penyelesaian masalah

Masalah Kemungkinan Punca Penyelesaian
Tiada paparan/Peranti tidak dihidupkan No power, faulty power supply, incorrect connection. Check power cable and source. Ensure correct voltage.
Unstable or inaccurate pH readings Electrode not calibrated, dirty electrode, damaged electrode, air bubbles, incorrect temperature compensation. Recalibrate electrode. Clean electrode. Replace electrode if damaged. Ensure electrode is fully submerged. Check ATC settings.
Mesej "Ralat" dipaparkan Electrode fault, out of range measurement, internal device error. Check electrode connection. Try another electrode if available. Refer to specific error codes in a detailed technical manual. Contact support if persistent.
Masa tindak balas yang perlahan Aged or dirty electrode, low sampsuhu le. Clean or recondition electrode. Allow electrode to equilibrate with sample temperature. Consider replacing electrode.

If the problem persists after attempting these solutions, please contact Greisinger customer support or your local distributor.

9. Spesifikasi

Ciri Perincian
Pengeluar GREISINGER
Nombor Model Item 602331
Dimensi Produk (L x W x H) 5.5 x 8.2 x 8 cm; 9.07 gram
ASIN B00ICKLET6
Kuantiti barang 1
Battery(ies) included Tidak
Battery(ies) required Tidak
Date first available on Amazon.com.be 12 Ogos 2022
Discontinued by manufacturer Tidak
Ketersediaan alat ganti Maklumat tidak tersedia pada alat ganti

10. Waranti dan Sokongan

Greisinger products are manufactured to high-quality standards. For information regarding warranty terms and conditions, please refer to the warranty card included with your product or visit the official Greisinger webtapak.

For technical support, troubleshooting assistance beyond this manual, or to inquire about spare parts and service, please contact your authorized Greisinger dealer or the manufacturer directly. Contact information can typically be found on the product packaging or the official Greisinger webtapak.

Dokumen Berkaitan - GPHU 014 MP/BNC

Praview Manual Pengendalian GREISINGER GE xxx: Elektrod pH
Manual pengendalian yang komprehensif untuk elektrod pH siri GREISINGER GE xxx, meliputi keselamatan, asas, pengukuran, penentukuran, penyelenggaraan, pemilihan dan spesifikasi. Termasuk panduan terperinci untuk pengukuran pH yang tepat.
Praview GREISINGER EBUW 232 EASYBUS Protocol Converter Operating Manual
Operating manual for the GREISINGER EBUW 232 EASYBUS protocol converter, detailing its specifications, general information, and safety requirements.
Praview Manual GREISINGER GIA 20 EB / PK: Sambungan dan Operasi
Manual ini menyediakan arahan komprehensif untuk peranti paparan, pemantauan dan kawalan terkawal GREISINGER GIA 20 EB / PK. Ia meliputi peraturan keselamatan, sambungan elektrik untuk pelbagai isyarat input dan jenis output, konfigurasi peranti menggunakan perisian, titik suis dan tetapan penggera, pelarasan ofset/cerun, antara muka bersiri, kod ralat, spesifikasi dan nota pelupusan.
Praview Manual Pengendalian Termometer Ketepatan GREISINGER GMH 3710
Manual pengendalian ini menyediakan arahan terperinci untuk termometer ketepatan GREISINGER GMH 3710. Ia meliputi penggunaan yang dimaksudkan, langkah berjaga-jaga keselamatan, spesifikasi produk, pengendalian, konfigurasi, pilihan output, pelarasan input, sambungan probe, prinsip pengukuran suhu asas, mesej kerosakan dan garis panduan pelupusan untuk penderia suhu Pt100.
Praview Greisinger GDH 200 Series Manometers and Barometers: Technical Overview
Discover the Greisinger GDH 200 series handheld pressure measurement instruments. This document details the GDH 200-07 fine manometer, GDH 200-13 manometer, and GDH 200-14 vacuum/barometer, highlighting their specifications and features for professional use.
Praview GREISINGER GMH 38-LW1 / -LW2 Meter Lembapan Manual Pengendalian Lampiran
Lampiran manual pengendalian untuk set pengukur kelembapan GREISINGER GMH 38-LW1 / -LW2 untuk aplikasi pertanian. Meliputi penggunaan yang dimaksudkan, keselamatan, perihalan produk, pengendalian, prinsip pengukuran dan spesifikasi untuk serpihan kayu, bijirin, jerami dan jerami.