Altronix AL400ULACM

Altronix ACM Series Access Power Controllers User Manual

Model: AL400ULACM

1. Pengenalan

The Altronix AL400ULACM is an 8-fused output power supply and access power controller designed to convert a 115V AC 60Hz input into independently controlled 12V DC or 24V DC outputs. It provides a total of 4 amp at 12VDC or 3 amp at 24V DC continuous supply current.

This unit is engineered to route power to various access control hardware devices, including magnetic locks, electric strikes, and magnetic door holders. Outputs can operate in both Fail-Safe and/or Fail-Secure modes, activated by an open collector sink or normally open (NO) dry trigger input from an access control system, card reader, keypad, push button, or PIR sensor.

The AL400ULACM can be powered by a single common power source for both board operation and locking devices, or by two independent power sources for separate board and lock/accessory power.

2. Ciri-ciri Utama

3. Persediaan dan Pemasangan

Carefully unpack the Altronix AL400ULACM unit and inspect for any shipping damage. Ensure all components are present before proceeding with installation.

Altronix AL400ULACM Access Power Controller inside its enclosure, showing the main power supply board, the 8-fused output distribution board, and two sealed lead-acid batteries at the bottom.

Gambar 3.1: Dalaman view of the Altronix AL400ULACM unit, displaying the power supply board (top), the 8-output distribution board (middle), and two batteries (bottom) within the wall-mountable enclosure. Note the grounding wires connected to the enclosure.

3.1 Pemasangan

Mount the unit securely to a wall or suitable surface using appropriate fasteners. The enclosure is designed for indoor use. Ensure adequate ventilation around the unit.

3.2 Sambungan Pendawaian

Refer to the wiring diagrams provided with the physical product for detailed connection instructions specific to your application.

4. Arahan Operasi

Once properly installed and wired, the Altronix AL400ULACM operates automatically to provide regulated power to connected devices and manage access control functions.

4.1 Power Conversion and Distribution

The unit converts the incoming 115V AC to either 12V DC or 24V DC, depending on the configuration. This DC power is then distributed through the 8 fused outputs to your connected access control devices.

4.2 Access Control Integration

The outputs are controlled by external trigger inputs. When a valid trigger signal is received from your access control system (e.g., card swipe, keypad entry), the corresponding output will activate, powering or de-powering the connected locking device as configured (Fail-Safe or Fail-Secure mode).

4.3 Operasi Sandaran Bateri

In the event of an AC power failure, the unit will automatically and seamlessly switch to battery backup power, ensuring continuous operation of your access control system without interruption or voltage drop. The built-in charger maintains the batteries when AC power is present.

4.4 Fire Alarm Disconnect

If connected to an FACP, the unit can be configured to disconnect power to specific outputs upon receiving a fire alarm signal, facilitating emergency egress as required by safety regulations.

5. Penyelenggaraan

Regular maintenance ensures the longevity and reliable operation of your Altronix AL400ULACM unit.

All maintenance should be performed by qualified personnel with the power disconnected from the unit.

6. Penyelesaian masalah

This section provides basic troubleshooting steps for common issues. For more complex problems, contact Altronix technical support.

MasalahKemungkinan PuncaPenyelesaian
Tiada kuasa ke peranti yang disambungkan.No AC input power; Blown fuse on output; Faulty wiring; Power supply issue.Check AC power source and connections. Inspect and replace any blown fuses. Verify all wiring connections are secure. If problem persists, contact support.
Unit not switching to battery backup.Batteries not connected; Dead or faulty batteries; Battery supervision circuit issue.Ensure batteries are correctly connected with proper polarity. Test batteries and replace if necessary. Check battery supervision contacts.
Output not activating from trigger input.Incorrect trigger wiring; Faulty trigger device; Output configuration issue.Verify trigger input wiring. Test the trigger device (e.g., card reader). Review output configuration settings (Fail-Safe/Fail-Secure).
Unit terlalu panas.Poor ventilation; Overloaded outputs.Ensure adequate airflow around the unit. Reduce load on outputs if exceeding specified current limits.

7. Spesifikasi

ParameterNilai
Nombor ModelAL400ULACM
Input Voltage115V AC, 60Hz, 1.9 amp dinilai
Keluaran Voltage12V DC or 24V DC (selectable)
Total Output Current (12V DC)4 Amps continuous supply
Total Output Current (24V DC)3 Amps continuous supply
Number of Fused Outputs8
Peringkat Fius3.5 Amp setiap keluaran
Arus Pengecas Bateri0.7 Amp (AL400ULXB board)
Bateri yang serasiTwo 12VDC/12AH sealed lead acid or gel type
Dimensi Kepungan (W x H x D)12.25" x 15.5" x 4.5" (approx. 16.26 x 13.39 x 5.91 inches package dimensions)
Berat Barang10.09 paun
Suhu Operasi0°C hingga 49°C (32°F hingga 120°F)
PensijilanUL Listed, CSFM Approved, MEA Approved

8. Maklumat Waranti

Altronix stands behind the quality and reliability of its products. The AL400ULACM Access Power Controller is backed by a Waranti Seumur Hidup. For specific terms and conditions of the warranty, please refer to the official Altronix warranty statement or contact Altronix customer service.

9. Sokongan Teknikal

Should you require technical assistance or have questions regarding the installation, operation, or maintenance of your Altronix AL400ULACM unit, please contact Altronix technical support directly.

For the most up-to-date contact information, please visit the official Altronix webtapak atau rujuk kepada dokumentasi yang disertakan dengan produk anda.

Dokumen Berkaitan - AL400ULACM

Praview Pengawal Kuasa Akses Altronix ACM Series dengan Panduan Pemasangan Bekalan Kuasa
This installation guide provides detailed instructions for the Altronix ACM Series Access Power Controllers with Power Supplies, including models AL400ULACM, AL600ULACM, AL1012ULACM, and AL1024ULACM. It covers power supply options, input and output configurations, fire alarm interface, and maintenance.
Praview Kit Altronix Trove2/Mercury dengan Panduan Pemasangan Output Bercantum
Panduan pemasangan untuk kit Altronix Trove2/Mercury, memperincikan pelbagai model keluaran bercantum, pilihan konfigurasi dan arahan pemasangan untuk sistem kawalan akses. Termasuk lebihview, carta konfigurasi, langkah pemasangan dan dimensi kepungan.
Praview Panduan Pemasangan Kit Integrasi Akses & Kuasa Trove Paxton Altronix T2PXK78 & T2PXK78D
Panduan pemasangan komprehensif untuk kit Altronix Trove Paxton (T2PXK78, T2PXK78D). Ketahui cara menyediakan sistem kawalan akses dan penyepaduan kuasa lanjutan yang menampilkan bekalan kuasa, pengawal dan modul Paxton Net2 Plus Altronix.
Praview Panduan Pemasangan Altronix/Lenel-S2 Trove Kits
Panduan pemasangan untuk Kit Trove Altronix/Lenel-S2 (S2 Security Platform), termasuk model T3SSK75F28 (Fused Output) dan T3SSK75F28D (PTC Outputs). Butiran kandungan kit, konfigurasi dan langkah pemasangan.
Praview Altronix MaximalDV Series Access Power Controllers Installation Guide
Installation guide for Altronix MaximalDV Series Access Power Controllers, covering models Maximal11DV, Maximal33DV, Maximal55DV, Maximal75DV, and Maximal77DV. Details features, specifications, wiring, and maintenance for access control systems.
Praview Modul Pengagihan Kuasa Altronix PD8/PD8CB - Spesifikasi dan Panduan Pemasangan
Panduan komprehensif untuk modul pengagihan kuasa Altronix PD8 dan PD8CB, yang memperincikan keseluruhannyaview, spesifikasi teknikal dan arahan pemasangan langkah demi langkah untuk 8 output terlakur atau dilindungi PTC.