The Wilo ECC29-15.50 Submersible Sump Pump is designed for efficient water removal in residential and light commercial applications. It features robust construction and reliable components to ensure long-lasting performance.

Key features include: Cast iron housing and volute, Thermoplastic Vortex Impeller, Stainless Steel bottom screened inlet, Replaceable tether float switch, Permanent split capacitor motor with thermal overload protection, 1.5-inch NPT discharge (1.25-inch adapter included), and a 10-ft power cord.

Wilo ECC29-15.50 Submersible Sump Pump

Image: Wilo ECC29-15.50 Submersible Sump Pump, showing its cast iron body, float switch, and discharge port.

Spesifikasi

AtributPerincian
JenamaWilo
Nombor Model2708304 (ECC29-15.50)
Voltage115 Volt
Kuasa kuda0.50 HP
bahanBesi Tuang, Keluli Tahan Karat
Berat Barang22 paun
Dimensi Produk9 x 6 x 11.4 inci
Sumber KuasaElektrik Bertali
Saiz Pelepasan1.5-inch NPT (1.25-inch adapter included)
Ciri-ciriThermal overload protection, Stainless Steel bottom screened inlet, Replaceable tether float switch

Persediaan

Proper installation is crucial for the safe and efficient operation of your sump pump. Always ensure power is disconnected before handling the pump.

  1. Keselamatan Diutamakan: Ensure the power supply to the sump pit area is turned off at the circuit breaker before beginning any installation work.
  2. Sump Pit Preparation: Ensure the sump pit is clean and free of debris. The pit should be large enough to accommodate the pump and allow for proper float switch operation.
  3. Peletakan Pam: Place the pump on a solid, level surface at the bottom of the sump pit. Avoid placing it directly on dirt or gravel, which can lead to clogging. Use a brick or concrete block if necessary.
  4. Discharge Pipe Connection: Connect a rigid PVC pipe (recommended) to the pump's 1.5-inch NPT discharge port. Use the included 1.25-inch adapter if your existing plumbing requires it. Install a check valve in the discharge line above the pump to prevent water from flowing back into the pit when the pump shuts off.
  5. Pelarasan Suis Apungan: Position the tether float switch so it can move freely without obstruction. Ensure it activates the pump at the desired water level and allows the pump to run long enough to adequately drain the pit before deactivating. Avoid contact with the pit walls or other pipes.
  6. Sambungan Kuasa: Plug the pump's 10-ft power cord into a properly grounded 115-volt GFCI (Ground Fault Circuit Interrupter) outlet. Do not use extension cords.
  7. Operasi Ujian: Once installed, fill the sump pit with water to verify the pump activates and deactivates correctly. Check for any leaks in the discharge line.

Operasi

The Wilo ECC29-15.50 sump pump operates automatically via its tether float switch. When the water level in the sump pit rises and lifts the float switch to its activation point, the pump will turn on and begin to discharge water.

Penyelenggaraan

Regular maintenance helps ensure the longevity and reliable performance of your sump pump. Always disconnect power before performing any maintenance.

Menyelesaikan masalah

Before attempting any troubleshooting, always disconnect the pump from the power source. If you are unsure about any step, consult a qualified electrician or plumber.

MasalahKemungkinan PuncaPenyelesaian
Pam tidak berjalan.No power; tripped GFCI; float switch stuck or defective; motor overheated.Check power supply and GFCI. Ensure float switch moves freely. Allow motor to cool if overheated. Replace float switch if defective.
Pam berjalan secara berterusan.Float switch stuck in "on" position; check valve faulty; continuous water inflow.Clear obstructions around float switch. Inspect/replace check valve. Investigate source of continuous water inflow.
Pump runs but does not remove water.Clogged inlet screen or impeller; air lock; discharge pipe blocked or frozen; pump not submerged.Clean inlet screen and impeller. Clear air lock by tilting pump. Check discharge pipe for blockages. Ensure pump is fully submerged.
Pam bising atau bergetar secara berlebihan.Debris in impeller; pump not sitting level; worn bearings (less common for new pump).Clean impeller. Ensure pump is on a stable, level surface. If noise persists, professional service may be required.

Waranti dan Sokongan

For specific warranty information regarding your Wilo ECC29-15.50 Submersible Sump Pump, please refer to the documentation included with your purchase or visit the official Wilo webtapak. Syarat jaminan biasanya meliputi kecacatan pembuatan untuk tempoh tertentu dari tarikh pembelian.

For technical support, parts, or service inquiries, please contact Wilo customer service directly. Have your model number (2708304) and purchase date ready when contacting support.

You can often find contact information for Wilo on their official webtapak atau melalui peruncit produk anda.

Dokumen Berkaitan - 2708304

Praview Wilo-EMU FA + FK 17.1, FK 202, FK 34, FK 42 Installation and Operating Instructions
This document provides comprehensive installation and operating instructions for the Wilo-EMU FA and FK series submersible sewage pumps, including models FK 17.1, FK 202, FK 34, and FK 42. It covers essential safety guidelines, product details, installation procedures, commissioning steps, maintenance, and troubleshooting for reliable operation.
Praview Wilo Submersible Motor Pumps: Installation and Operating Instructions
Detailed installation and operating instructions for Wilo submersible motor pumps, including models like Wilo-EMU, Wilo-Sub TWI, and Wilo-Actun ZETOS-K. Covers safety, product description, transport, installation, startup, maintenance, shutdown, and troubleshooting.
Praview Wilo-Drain TS/TSW 32 Installation and Operating Instructions
This document provides essential installation and operating instructions for the Wilo-Drain TS/TSW 32 submersible pump. It covers critical safety information, detailed product specifications, application guidelines, step-by-step installation procedures, commissioning steps, operational advice, maintenance recommendations, and proper disposal methods for domestic sewage and drainage applications.
Praview Wilo Submersible Motor Pumps: Installation and Operating Instructions
Comprehensive guide for installing, operating, and maintaining Wilo submersible motor pumps, including models like Wilo-EMU, Wilo-Sub, and Wilo-Actun. Essential safety and technical information for proper use and longevity.
Praview Wilo-Sub TWI 4 ... 6 Installation and Operating Instructions
Comprehensive installation and operating instructions for Wilo-Sub TWI 4 and TWI 6 series submersible pumps. Covers product features, technical data, installation procedures, electrical connections, commissioning, maintenance, and troubleshooting for domestic, agricultural, and industrial applications.