pengenalan
The Dataprobe iBoot-G2+ is a web-enabled power switch designed for remote power control and management of connected devices. It features a single NEMA 5-15 circuit outlet, allowing users to remotely reboot, power on, or power off equipment from any location via a web browser or the iBoot Cloud Service. This device is ideal for managing remote servers, network equipment, or any device that benefits from automated power cycling to ensure continuous operation and minimize downtime. The iBoot-G2+ also includes two expansion I/O ports for custom integration with external sensors or alarms, providing enhanced flexibility for various applications.
Persediaan dan Pemasangan
Kandungan Pakej
- iBoot-G2+ Web Power Switch Unit
- Kord Kuasa
- Kabel Ethernet
- Terminal Blocks for Expansion Ports (2)

Figure 1: iBoot-G2+ unit with standard accessories.
Sambungan Fizikal
- Sambungkan Kuasa: Plug the provided power cord into the A/C Input port on the iBoot-G2+ and then into a standard wall outlet.
- Sambungkan Rangkaian: Connect an Ethernet cable from your network router or switch to the Ethernet port on the iBoot-G2+. Ensure your network has DHCP enabled for automatic IP address assignment.
- Sambungkan Peranti: Plug the device you wish to control into the A/C Output port of the iBoot-G2+.

Figure 2: Rear and Front View of iBoot-G2+ showing A/C Input, A/C Output, Ethernet, and Expansion Ports.

Rajah 3: Terperinci view of the A/C Output and Expansion I/O Ports (EXP1, EXP2) on the iBoot-G2+.
Konfigurasi Awal (Web Antara muka)
Once connected, the iBoot-G2+ will obtain an IP address from your network's DHCP server. You can discover its IP address using the iBoot Discovery Tool (available on the Dataprobe website) or by checking your router's connected devices list.
- Buka a web browser and enter the iBoot-G2+'s IP address in the address bar.
- Log in using the default credentials (refer to the included quick start guide for default username and password).
- It is highly recommended to change the default password immediately for security purposes.
- Configure network settings (e.g., static IP, DNS) if required for your network environment.
Pengembangan Port I/O
The iBoot-G2+ features two expansion I/O ports (EXP1 and EXP2) for integrating external devices such as sensors or alarms. These ports allow for customized power management solutions based on external triggers. Refer to the advanced user guide on the Dataprobe website for detailed instructions on configuring and utilizing these ports.
Operating the iBoot-G2+
Kawalan Kuasa Jauh
The primary function of the iBoot-G2+ is to provide remote control over the power to a connected device. This can be done via the web interface or the iBoot Cloud Service.
- Hidupkan kuasa: Applies power to the connected device.
- Matikan: Removes power from the connected device.
- Power Cycle (Reboot): Briefly removes power and then reapplies it, effectively rebooting the connected device. This is a common operation for unresponsive network equipment.
AutoPing Reboot Feature
The AutoPing feature allows the iBoot-G2+ to automatically monitor the responsiveness of a network device (e.g., a router or server) by continuously sending ping requests to a specified IP address. If the device fails to respond after a configurable number of attempts or duration, the iBoot-G2+ will automatically power cycle the connected equipment.
- Configure target IP addresses for ping monitoring.
- Set the ping interval and the number of failed pings before a power cycle is initiated.
- This feature ensures minimal downtime for critical network components.
iBoot Cloud Service Access
Dataprobe offers a free iBoot Cloud Service that provides secure, centralized power control and monitoring for multiple iBoot devices from anywhere. This service simplifies management, especially for deployments with numerous iBoot units across different locations.

Figure 4: iBoot Cloud Service for centralized management.
- Register your iBoot-G2+ with the iBoot Cloud Service.
- Manage devices, view status, and perform power operations through a single web antara muka.
Makluman Masa Nyata
The iBoot-G2+ can send instant notifications via email or SMS for various events, including power status changes, automatic reboots, or network connectivity issues. This keeps you informed about the status of your connected equipment and the iBoot-G2+ itself.
- Configure alert recipients and notification types in the web antara muka.
- Customize which events trigger alerts.
Penyelenggaraan
The iBoot-G2+ is designed for reliable, low-maintenance operation. Regular maintenance primarily involves ensuring proper ventilation and keeping the unit clean.
- Pembersihan: Gunakan kain lembut dan kering untuk membersihkan bahagian luar unit. Jangan gunakan pembersih cecair atau pelarut.
- Pengudaraan: Ensure the unit is placed in an area with adequate airflow to prevent overheating. Do not block ventilation openings.
- Kemas kini Firmware: Periodically check the Dataprobe weblaman web untuk kemas kini perisian tegar. Kemas kini perisian tegar boleh menyediakan ciri baharu, penambahbaikan prestasi dan peningkatan keselamatan. Ikut arahan yang disediakan bersama pakej kemas kini perisian tegar dengan teliti.
Menyelesaikan masalah
Isu dan Penyelesaian Biasa
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| iBoot-G2+ not accessible via web antara muka. | Incorrect IP address, network cable disconnected, DHCP issue, unit not powered on. | Verify power and network cable connection. Use the iBoot Discovery Tool to find the IP address. Check router's DHCP client list. Ensure the unit is powered on (Outlet On LED should be lit). |
| Connected device does not power cycle. | Device not properly plugged into iBoot-G2+ output, iBoot-G2+ not receiving power, AutoPing not configured correctly. | Ensure the device is securely plugged into the A/C Output. Check iBoot-G2+ power. Review AutoPing settings in the web interface (target IP, ping interval, retry count). |
| AutoPing not working as expected. | Incorrect target IP, network firewall blocking pings, device being pinged is truly unresponsive. | Double-check the target IP address. Ensure no firewall rules are blocking ICMP (ping) traffic from the iBoot-G2+. Confirm the target device is indeed unresponsive. |
| Programmatic control (e.g., via command-line tool) is unreliable. | Network latency, firewall issues, software version incompatibility. | Ensure stable network connection. Check firewall settings on both the iBoot-G2+ and the controlling machine. Verify you are using the latest version of the control software. Consider using the web interface for critical operations if programmatic control is unstable. |
| Hostname not registering with DNS. | Device firmware limitation, network DNS configuration. | Access the device via its IP address directly. Check Dataprobe's support resources for firmware updates that may address this. Ensure your DNS server is configured to accept dynamic updates if applicable. |
For further assistance, refer to the comprehensive user manual available on the Dataprobe website or contact Dataprobe technical support.
Spesifikasi
| Ciri | Perincian |
|---|---|
| Nombor Model | iBoot-G2+ |
| Jenama | Dataprobe |
| Jenis Output | Single NEMA 5-15 Circuit Outlet |
| Input Voltage | 105-125V, 60Hz, 12A Max / 210-240V, 50Hz, 10A Max (AC) |
| Pelabuhan Pengembangan | 2 I/O Ports (EXP1, EXP2) |
| Ketersambungan | Ethernet (RJ45) |
| Dimensi (LxWxH) | 3.2 x 4.2 x 2 inci |
| Berat badan | 1 paun |
| warna | Hitam |
| Tarikh Tersedia Pertama | 14 Januari 2013 |
Maklumat Waranti
Dataprobe products are manufactured to high quality standards. For detailed warranty information, including terms, conditions, and duration, please refer to the warranty statement provided with your product or visit the official Dataprobe webtapak. Simpan bukti pembelian anda untuk tuntutan waranti.
Sokongan dan Hubungan
For technical support, product inquiries, or additional documentation, please visit the Dataprobe official webtapak atau hubungi bahagian perkhidmatan pelanggan mereka.
- rasmi Webtapak: www.dataprobe.com
- Sumber Sokongan: Access FAQs, downloads, and detailed user guides.
- Hubungi: Rujuk kepada website for contact numbers and email addresses for technical support.



