1. Pengenalan
This manual provides essential instructions for the proper use, maintenance, and care of your Hypertherm 220818 Drag Cutting Shield. This shield is a critical consumable component designed for use with Hypertherm Powermax65, Powermax85, and Powermax105 handheld plasma torches, specifically for operations requiring a current rating between 45 and 85 Amperes. Adhering to these guidelines will ensure optimal performance, safety, and longevity of the product.

Rajah 1: Hypertherm 220818 Drag Cutting Shield. This image shows the copper-colored shield component, designed for plasma cutting torches, with part numbers visible on its side.
2. Maklumat Keselamatan
Always prioritize safety when working with plasma cutting equipment. Refer to your plasma system's main operating manual for comprehensive safety instructions. Key safety considerations include:
- Pakai peralatan pelindung diri (PPE) yang sesuai, termasuk topi keledar kimpalan, sarung tangan, dan pakaian pelindung.
- Ensure proper ventilation in the work area to avoid inhaling fumes.
- Disconnect power to the plasma system before changing consumables or performing maintenance.
- Handle hot components with care to prevent burns.
3. Persediaan dan Pemasangan
The Hypertherm 220818 Shield is a consumable part that requires correct installation for optimal performance and safety. Follow these steps to install the shield onto your Powermax torch:
- Pemutusan Kuasa: Ensure the plasma cutting system is completely powered off and disconnected from the main power supply.
- Torch Preparation: Carefully remove the retaining cap from the torch head by unscrewing it. This will expose the existing consumables.
- Remove Old Shield: If replacing an old shield, gently pull it off the electrode and nozzle assembly. Inspect other consumables (electrode, nozzle, swirl ring) for wear and replace if necessary.
- Install New Shield: Align the new Hypertherm 220818 Shield with the torch head and push it firmly into place over the nozzle and electrode assembly. Ensure it seats correctly.
- Reattach Retaining Cap: Screw the retaining cap back onto the torch head until it is hand-tight. Do not overtighten.
- Pemeriksaan Visual: Verify that all consumables are properly seated and aligned before reconnecting power and operating the system.

Rajah 2: Alternatif view of the Hypertherm 220818 Shield. This image provides another perspective of the shield, highlighting its design and connection points for the plasma torch.
4. Arahan Operasi
The 220818 Shield is designed for drag cutting applications. Proper operating techniques are crucial for achieving clean cuts and maximizing consumable life.
- Drag Cutting: For drag cutting, the shield is designed to make direct contact with the workpiece. Maintain a consistent, light drag on the material surface.
- Torch Angle: Hold the torch perpendicular to the workpiece for most cuts. A slight angle may be used for beveling or specific applications.
- Kelajuan Perjalanan: Adjust travel speed according to material thickness and desired cut quality. Too slow can lead to excessive dross; too fast can result in incomplete cuts.
- Amperage Setting: Ensure your plasma system's amperage is set within the recommended range of 45-85 A for this shield. Refer to your plasma cutter's manual for specific settings based on material type and thickness.
- Menindik: When piercing thicker materials, use the recommended piercing technique from your plasma system's manual to avoid damage to the shield and other consumables.
5. Penyelenggaraan dan Penjagaan
Regular inspection and proper maintenance of the shield and other consumables are vital for consistent performance and extended lifespan.
- Pemeriksaan Harian: Before each use, inspect the shield for signs of wear, such as excessive pitting, gouging, or deformation of the orifice.
- Pembersihan: If the shield accumulates spatter, gently clean it with a non-abrasive tool. Avoid using harsh chemicals or abrasive materials that could damage the shield's surface.
- Penggantian: Replace the shield when its performance degrades, or visible damage is present. A worn shield can lead to poor cut quality, increased dross, and potential damage to other torch components.
- Storan: Store new shields in a clean, dry environment to prevent contamination or damage.
6. Penyelesaian masalah
If you encounter issues during operation, consider the following common troubleshooting steps related to the shield:
- Poor Cut Quality / Excessive Dross:
- Inspect the shield for wear or damage. Replace if necessary.
- Check other consumables (nozzle, electrode) for wear.
- Verify correct travel speed and amptetapan erage.
- Torch Not Firing / Intermittent Arc:
- Ensure the shield is properly seated and the retaining cap is hand-tight.
- Check for any foreign material obstructing the shield's orifice.
- Inspect the electrode and nozzle for damage or contamination.
- Jangka Hayat Boleh Digunakan Pendek:
- Confirm correct amperage and air pressure settings for the material being cut.
- Avoid excessive piercing or cutting too slowly.
- Ensure proper torch height and drag technique.
For further troubleshooting, consult your Hypertherm Powermax system's comprehensive operating manual or contact Hypertherm technical support.
7. Spesifikasi
| Atribut | Nilai |
|---|---|
| Nombor Model | 220818 |
| Keserasian | Hypertherm Powermax65, Powermax85, Powermax105 Handheld Plasma Torches |
| Penilaian Semasa | 45 - 85 Amperes |
| Jenis Produk | Drag Cutting Shield (Consumable) |
| Dimensi | Kira-kira 1 x 1 x 6 inci |
| Berat badan | Kira-kira 0.63 auns |
| Pengeluar | Hypertherm |
8. Waranti dan Sokongan
This Hypertherm 220818 Shield is a consumable item. Specific warranty information for consumables may vary. Please refer to the official Hypertherm website or contact your authorized Hypertherm dealer for detailed warranty policies applicable to consumable parts.
For technical assistance, product inquiries, or to locate an authorized service center, please visit the official Hypertherm website or contact their customer support directly. Always provide the model number (220818) and your plasma system's model number when seeking support.