1. Pengenalan
This manual provides essential instructions for the safe and effective operation of the Amprobe AM-570 Industrial Digital Multimeter. The AM-570 is designed for professionals requiring accurate and reliable measurements in various electrical, HVAC/R, and industrial maintenance applications. Please read this manual thoroughly before using the device to ensure proper function and safety.
2. Maklumat Keselamatan
To prevent electric shock or personal injury, and to avoid damage to the meter or the equipment under test, observe the following safety guidelines:
- Sentiasa mematuhi kod keselamatan tempatan dan nasional.
- The Amprobe AM-570 is rated for CAT IV 600 V and CAT III 1000 V. Do not exceed these ratings.
- Inspect test leads for damaged insulation or exposed metal before use. Replace damaged leads immediately.
- Pastikan suis fungsi berada di kedudukan yang betul untuk pengukuran yang sedang dilakukan.
- Jangan gunakan lebih daripada vol yang dinilaitage between terminals or between any terminal and ground.
- Berhati-hati apabila bekerja dengan voltagmelebihi 30 V AC RMS, puncak 42 V atau 60 V DC. Voltan initagia menimbulkan bahaya kejutan.
- Putuskan kuasa ke litar dan nyahcas semua voltan tinggitage capacitors before performing resistance, continuity, diode, or capacitance tests.
- Do not operate the meter if it appears damaged or if it is not operating properly.
- Gantikan bateri sebaik sahaja penunjuk bateri lemah muncul untuk memastikan bacaan yang tepat.
- Semasa menservis meter, gunakan hanya alat ganti yang ditentukan.
3. Kandungan Pakej
Verify that all items listed below are present and undamaged:
- Amprobe AM-570 Industrial Digital Multimeter
- Test Leads (one pair, red and black)
- K-Type Thermocouple Probes (two)
- Membawa Sarung
- 9V Battery (pre-installed or included separately)
- Manual Pengguna (dokumen ini)

Imej 3.1: The Amprobe AM-570 Digital Multimeter shown with its standard accessories, including test leads, two K-type thermocouple probes, and a soft carrying case.
4. Ciri-ciri Produk
The Amprobe AM-570 offers a comprehensive set of features for diverse electrical measurements:
- Mengukur Vol. AC/DCtage sehingga 1000 V
- Measures AC/DC Current
- Measures Resistance, Frequency, Capacitance, and Temperature
- Measures Duty Cycle
- True-RMS technology for accurate readings in non-linear loads
- Low Z mode to detect stray voltages and eliminate ghost readings
- Low Pass Filter for accurate voltage measurements on variable frequency drives (VFDs)
- Vol. Bukan Kenalantage (NCV) detection for quick voltage presence checks
- Built-in flashlight for illumination in dimly lit areas
- Data Hold, MAX/MIN, and Peak Hold functions
- CAT IV 600 V / CAT III 1000 V safety rating

Imej 4.1: The Amprobe AM-570 Digital Multimeter, showing its display, rotary dial, and function buttons. The display indicates a DC voltage reading of 119.4 V.

Imej 4.2: Bersudut view daripada Amprobe AM-570 Digital Multimeter, highlighting the clear digital display, which currently shows a frequency reading of 0.000 kHz.
5. Persediaan
5.1 Pemasangan Bateri
- Pastikan meter dimatikan.
- Cari petak bateri di belakang meter.
- Gunakan pemutar skru untuk melonggarkan skru yang menahan penutup bateri.
- Tanggalkan penutup bateri.
- Insert a new 9V battery, observing correct polarity.
- Gantikan penutup bateri dan kencangkannya dengan skru.
5.2 Menghubungkan Petunjuk Ujian
Always connect the black test lead to the COM (common) terminal. Connect the red test lead to the appropriate input terminal based on the measurement function:
- VΩHz: For voltage, resistance, frequency, capacitance, and diode/continuity measurements.
- mAµA: For milliampere dan mikroampsebelum pengukuran semasa.
- 10A: For high current (up to 10A) measurements.

Imej 5.1: The Amprobe AM-570 Digital Multimeter shown with its integrated kickstand extended, allowing for hands-free viewdalam semasa operasi.
6. Arahan Operasi
The AM-570 features a rotary dial for selecting primary measurement functions and push buttons for secondary functions and settings.
6.1 Pemilihan Fungsi
Turn the rotary dial to the desired measurement function. Use the PILIH button to toggle between primary and secondary functions within a single dial position (e.g., AC/DC voltage, resistance/continuity/diode).
6.2 Fungsi Pengukuran
- Voltage (V~ / V--): Select the V~ (AC) or V-- (DC) position. Connect test leads in parallel with the circuit.
- Current (10A / mAµA): Select the 10A or mAµA position. Connect the meter in series with the circuit. Ensure correct terminal connection.
- Rintangan (Ω): Select the Ω position. Ensure power is off and capacitors are discharged. Connect test leads across the component.
- Kesinambungan ())): Select the Ω position and press PILIH until the continuity symbol appears. A continuous beep indicates continuity.
- Diode Test (→|): Select the Ω position and press PILIH until the diode symbol appears. Connect leads across the diode.
- Kapasitansi (F): Select the F position. Ensure power is off and capacitors are discharged. Connect leads across the capacitor.
- Frequency (Hz) / Duty Cycle (%): Select the Hz% position. Connect leads to the signal source. Press PILIH to toggle between frequency and duty cycle.
- Suhu (° C / ° F): Select the TEMP °C/°F position. Insert K-type thermocouple probes into the T1 and T2 inputs. Press PILIH to toggle between Celsius and Fahrenheit.
- Vol. Bukan Kenalantage (NCV): Select the NCV position. Hold the top of the meter near a live conductor. The NCV indicator and audible alarm will activate if voltage dikesan.
- Low Z Mode: Select the LoZ V~ position for AC voltage measurements with low impedance. This helps to eliminate ghost voltages.
- Penapis Lulus Rendah: Activated automatically in certain AC voltage modes, this filter allows for accurate measurements on variable frequency drives.
6.3 Fungsi Khas
- JULAT: Manually select the measurement range instead of auto-ranging.
- REL (Relative Mode): Measures the difference between a stored reference value and the current reading.
- MAX/MIN: Records the maximum and minimum values over a measurement period.
- TAHAN: Freezes the current display reading.
- PEAK (1ms): Captures fast transient peaks (positive and negative) with a 1ms response time.

Image 6.1: An electrician utilizing the Amprobe AM-570 Digital Multimeter to perform voltage measurements within an industrial electrical panel, demonstrating practical application.
7. Penyelenggaraan
7.1 Pembersihan
Lap meter dengan iklanamp kain dan detergen lembut. Jangan gunakan bahan pelelas atau pelarut. Pastikan meter kering sebelum digunakan.
7.2 Penggantian Bateri
Refer to Section 5.1 for detailed instructions on replacing the 9V battery. Replace the battery promptly when the low battery indicator appears on the display.
7.3 Penggantian Fius
If the current measurement functions cease to operate, the internal fuses may need replacement. Fuse replacement should only be performed by qualified personnel. Refer to the full service manual for fuse specifications and replacement procedures. Always use fuses with the specified voltage dan penilaian semasa.
7.4 Penyimpanan
When not in use for extended periods, remove the battery to prevent leakage. Store the meter in a cool, dry environment, preferably in its carrying case.
8. Penyelesaian masalah
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Meter tidak dihidupkan | Bateri mati atau tidak dipasang dengan betul | Check battery polarity; replace battery (see Section 5.1). |
| No reading or "OL" (Overload) displayed | Incorrect function selected; open circuit; measurement range exceeded | Verify function switch position; check circuit continuity; select a higher range or auto-range. |
| Bacaan tidak tepat | Low battery; dirty test leads/terminals; external interference | Replace battery; clean leads and terminals; move away from strong electromagnetic fields. |
| Pengukuran arus tidak berfungsi | Fius ditiup | Replace fuse (see Section 7.3). |
| NCV function inconsistent | Environmental factors; sensor position | Ensure direct proximity to live conductor; NCV is for indication only, use test leads for precise voltage pengesahan. |
9. Spesifikasi
| Parameter | Perincian |
|---|---|
| Model | PG-570 |
| Pengeluar | Ampjubah |
| Keupayaan Pengukuran | AC / DC Voltage, AC/DC Current, Resistance, Frequency, Capacitance, Temperature, Duty Cycle |
| Penilaian Keselamatan | CAT IV 600 V / CAT III 1000 V |
| Betul-RMS | ya |
| Low Z Mode | ya |
| Penapis Lulus Rendah | ya |
| Sumber Kuasa | Bateri 9V |
| Dimensi Produk | 4 x 10 x 2 inci (10.16 x 25.4 x 5.08 cm) |
| Berat Barang | 13.05 auns (370 gram) |
| warna | Black with Red overmolding |
10. Waranti dan Sokongan
Amprobe products are designed for reliability and performance. This product is covered by a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Ampjubah webtapak.
For technical support, service, or replacement parts, please contact Amprobe customer service. Contact information can typically be found on the Ampjubah webtapak atau dalam pembungkusan produk.