Eaton KD1-1

Eaton Heinemann KD1-1 Thermal Circuit Breaker

Manual Pengguna

Model: KD1-1

1. Pengenalan

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Eaton Heinemann KD1-1 Thermal Circuit Breaker. Please read this manual thoroughly before proceeding with any installation or operation.

The KD1-1 is a single-pole (1P) thermal circuit breaker designed for protection in electrical circuits up to 250V AC and 50V DC, with a current rating of 1 Ampere. It is typically panel-mounted and features a push-to-reset mechanism.

2. Maklumat Keselamatan

AMARAN: Risiko Renjatan Elektrik atau Kebakaran.

  • Pemasangan dan servis hendaklah dilakukan oleh kakitangan yang berkelayakan sahaja.
  • Always disconnect power to the circuit before installing, servicing, or removing the circuit breaker.
  • Ensure that the circuit breaker's voltage and current ratings match the application requirements.
  • Do not use this device in life-support applications or where failure could result in serious injury or property damage.
  • Mematuhi semua kod dan peraturan elektrik tempatan dan nasional.

3. Persediaan dan Pemasangan

The KD1-1 circuit breaker is designed for panel mounting.

  1. Penyediaan: Ensure the power supply to the circuit is completely disconnected and verified with a voltage penguji.
  2. Pemasangan: Insert the circuit breaker into the designated panel cutout. Secure it according to the panel design, typically using a mounting nut or clip (not included).
  3. Pendawaian: Connect the circuit wires to the appropriate terminals on the circuit breaker. Ensure all connections are tight and secure to prevent loose contacts, which can cause overheating or arcing. Refer to the wiring diagram for your specific application.
  4. Pengesahan: Double-check all connections and ensure the circuit breaker is firmly mounted before restoring power.
Eaton Heinemann KD1-1 Thermal Circuit Breaker

Rajah 1: Eaton Heinemann KD1-1 Thermal Circuit Breaker. This image displays the cylindrical body of the circuit breaker with two terminals extending from one end. The other end features a white circular button labeled 'PUSH RE-CIRK-IT', indicating its reset function.

4. Arahan Operasi

The KD1-1 is a thermal circuit breaker designed to protect electrical circuits from overcurrent conditions. It operates automatically and can be manually reset.

  1. Operasi Biasa: Under normal operating conditions, the circuit breaker allows current to flow through the circuit.
  2. Overcurrent Trip: If an overcurrent condition (e.g., overload or short circuit) occurs, the internal thermal mechanism will heat up and trip, interrupting the circuit to prevent damage to equipment or wiring. When tripped, the white 'PUSH RE-CIRK-IT' button will typically pop out.
  3. Menetapkan semula Pemutus: After the circuit breaker trips, identify and resolve the cause of the overcurrent. Once the fault is cleared, firmly press the 'PUSH RE-CIRK-IT' button (as shown in Figure 1) to reset the breaker and restore power to the circuit. If the breaker immediately trips again, do not force it; investigate the underlying electrical issue further.

5. Penyelenggaraan

The Eaton Heinemann KD1-1 Thermal Circuit Breaker requires minimal maintenance.

  • Pemeriksaan Berkala: Periksa pemutus litar secara berkala untuk sebarang tanda kerosakan fizikal, perubahan warna atau sambungan yang longgar.
  • Pembersihan: If necessary, gently clean the exterior of the circuit breaker with a dry, lint-free cloth. Do not use abrasive cleaners or solvents.
  • Elakkan Tampering: Do not attempt to open, modify, or repair the circuit breaker. Doing so will void any warranty and could compromise safety.

6. Penyelesaian masalah

If you encounter issues with your KD1-1 circuit breaker, consider the following:

  • Perjalanan Pemutus Kerap:
    • Lebihan beban: Litar mungkin menarik lebih arus daripada pemutus 1 Ampere rating. Reduce the load on the circuit.
    • Litar pintas: A direct connection between live and neutral/ground wires can cause a sudden surge. Inspect wiring for damage or faulty appliances.
    • Perkakas rosak: Disconnect appliances one by one to identify a defective unit.
  • Pemutus Tidak Tetapkan Semula:
    • Ensure the overcurrent condition has been resolved. The breaker may not reset if the fault is still present.
    • If the breaker still does not reset after clearing the fault, it may be damaged and require replacement.
  • Tiada Kuasa untuk Litar:
    • Check if the breaker has tripped (button popped out).
    • Verify the main power supply to the panel.
    • Periksa sambungan pendawaian untuk kelonggaran atau kerosakan.

Jika langkah penyelesaian masalah tidak menyelesaikan isu, rujuk juruelektrik bertauliah.

7. Spesifikasi

ParameterNilai
JenamaEaton Heinemann
ModelKD1-1
Penilaian Semasa1 Ampsebelum
Voltage Rating (AC)250V
Voltage Rating (DC)50V
Bilangan Tiang1
Jenis PemasanganPemasangan Panel
Jenis Pemutus Litarterma
Mematuhi RoHSya

8. Maklumat Waranti

Eaton products are manufactured to high standards. For specific warranty terms and conditions applicable to the KD1-1 Thermal Circuit Breaker, please refer to the official Eaton warranty documentation provided at the time of purchase or visit the Eaton website. Warranty coverage typically applies to defects in materials and workmanship under normal use.

9. Sokongan

For technical assistance, product inquiries, or further support, please contact Eaton customer service or visit the official Eaton website. When contacting support, please have your product model number (KD1-1) available.

Eaton Official Webtapak: www.eaton.com

Dokumen Berkaitan - KD1-1

Praview 伊顿 NZM 1-4 系列塑壳断路器样本
伊顿 NZM 1-4系列塑壳断路器样本,提供关于断路器、隔离开关、塑壳开关的技术规格、型号规则、安装附件等详细信息。
Praview Manual Pengguna Pemutus Litar Udara Eaton Magnum LV (1812.900A)
Manual pengguna yang komprehensif untuk Eaton Magnum LV-Air Circuit Breaker (model 1812.900A), memperincikan pemasangan, operasi, penyelenggaraan, penyelesaian masalah dan bahagian pembaharuan. Meliputi konfigurasi tetap dan keluar dengan sistem tersandung elektronik.
Praview 伊顿新一代空气断路器 IZM9 系列:卓越的解决方案
了解伊顿新一代 IZM9系列空气断路器,为全球电力系统提供创新、可靠且高效的动力管理解决方案。该系列产品凭借先进的PXR 电子脱扣平台、增强的安全特性(如 ARMS 闪弧减少维护系统)以及强大的通讯能力,广泛应用于建筑、信息技术、工业机械和能源公用事业等多个领域,满足客户日益增长和多样化的需求。
Praview Arahan Pemasangan dan Operasi Pemutus Litar Vakum Eaton E-VAC HV
Panduan ini menyediakan butiran pemasangan, operasi, penyelenggaraan dan teknikal yang penting untuk Eaton E-VAC Enclosed Indoor High Voltage Pemutus Litar Vakum (Model IL550-0501001E), memastikan penggunaan yang selamat dan cekap dalam aplikasi grid industri dan kuasa.
Praview Risalah Arahan EATON 11/25 IL019140ZU: Panduan Pemasangan RCCB dan RCBO
Arahan pemasangan terperinci dan spesifikasi teknikal untuk Pemutus Litar Arus Baki (RCCB) dan Pemutus Arus Baki dengan Perlindungan Arus Lebih (RCBO) siri EATON PL6, PL7, HN, PF6, PF7 dan HNC, termasuk gambar rajah pendawaian dan data elektrik.
Praview Panduan Pemilihan Eaton Power Secure: Pemutus Litar dan Penyelesaian Kawalan Motor
Temui Panduan Pemilihan Power Secure Eaton yang komprehensif, menampilkan Pemutus Litar Udara (Siri PSL), Pemutus Litar Kes Acuan (Siri PDC, BZM), Pemutus Litar Miniatur (Siri E6X) dan Siri D-Line untuk Kawalan & Perlindungan Motor. Dapatkan spesifikasi produk terperinci, data teknikal dan maklumat pemilihan untuk keperluan pengedaran dan perlindungan elektrik.