Wilo TMW32/11

Wilo TMW32/11 Drain Pump

Manual Arahan

1. Pengenalan

This instruction manual provides important information for the safe and efficient installation, operation, and maintenance of your Wilo TMW32/11 Drain Pump. Please read this manual thoroughly before attempting to install or operate the pump. Keep this manual for future reference.

The Wilo TMW32/11 is a submersible pump designed for pumping clear or slightly contaminated water, suitable for drainage applications in domestic and light commercial settings.

2. Arahan Keselamatan

AMARAN: Kegagalan mematuhi arahan keselamatan ini boleh mengakibatkan renjatan elektrik, kebakaran, kecederaan serius atau kematian.

3. Persediaan

3.1 Membongkar

Carefully remove the pump and all accessories from the packaging. Inspect for any signs of damage during transit. If damage is found, do not proceed with installation and contact your supplier.

3.2 Penempatan

Position the pump in the lowest part of the area to be drained. Ensure there is sufficient space around the pump for water intake and for the float switch to move freely without obstruction. The pump should be placed on a solid, level surface to prevent it from sinking into soft ground or mud.

3.3 Sambungan Hos

Connect a suitable discharge hose to the pump's outlet. Ensure the connection is secure and watertight to prevent leaks. The hose should be routed without kinks or sharp bends to ensure optimal flow.

3.4 Sambungan Elektrik

Plug the pump's power cable into a grounded electrical outlet. Ensure the voltage and frequency of your power supply match the specifications on the pump's rating plate. The pump is equipped with a float switch for automatic operation.

Wilo TMW32/11 Drain Pump

Rajah 1: A view of the Wilo TMW32/11 drain pump, showing its compact green and black body, integrated power cable with plug, and the discharge outlet at the top. The float switch cable is also visible, wrapped around the handle.

4. Arahan Operasi

4.1 Permulaan Awal

Once the pump is correctly installed and connected, submerge it in water. The float switch will rise with the water level. When the water reaches a certain level, the float switch will activate the pump. The pump will continue to operate until the water level drops and the float switch deactivates it.

4.2 Operasi Automatik

The Wilo TMW32/11 pump is designed for automatic operation via its integrated float switch. The pump will automatically switch on when the water level rises to the activation point of the float switch and switch off when the water level drops to the deactivation point.

4.3 Ciri-ciri Prestasi

The performance of the pump (flow rate vs. head) varies depending on the specific model. Refer to the performance curve for detailed information on your pump's capabilities.

Wilo Drain TM/TMR/TMW 32 Performance Curve

Rajah 2: A graph illustrating the performance curves for various Wilo Drain TM/TMR/TMW 32 pump models. The horizontal axis represents flow rate (Q in m³/h) and the vertical axis represents head (H in m). Different lines indicate the performance characteristics for models like TM 32/8, TMW 32/8, TMR 32/7, TMR 32/8, TMW 32/11, and TMR 32/11, showing their respective head-flow relationships.

5. Penyelenggaraan

Regular maintenance ensures the longevity and efficient operation of your pump. Always disconnect the pump from the power supply before any maintenance.

6. Penyelesaian masalah

Sebelum menghubungi sokongan pelanggan, sila rujuk jadual berikut untuk isu biasa dan penyelesaiannya.

MasalahKemungkinan PuncaPenyelesaian
Pam tidak bermulaTiada bekalan kuasa
Suis apungan tersekat
Beban terma motor
Periksa sambungan kuasa dan pemutus litar
Ensure float switch moves freely
Allow motor to cool down, then restart
Pump runs but no water is pumped or flow is lowIntake screen clogged
Discharge hose kinked or blocked
Kunci udara dalam pam
Pam kering
Clean intake screen
Check and clear hose
Tilt pump to release air, restart
Ensure pump is fully submerged
Pump switches on/off frequentlyFloat switch movement restricted
Water level fluctuating rapidly
Check float switch for obstructions
Ensure stable water level or adjust float switch position if possible
Bunyi atau getaran yang luar biasaSerpihan dalam pendesak
Pump not stable
Disconnect power, inspect and clean impeller
Place pump on a firm, level surface

7. Spesifikasi

The following are the general specifications for the Wilo TMW32/11 Drain Pump:

AtributNilai
JenamaWilo
ModelTMW32/11
warnahijau
bahanplastik
GayaKlasik
Sumber KuasaKabel Elektrik
Berat Barang7 Kilogram
Kod Artikel Antarabangsa04016322477433
PengeluarWilo

Dokumen Berkaitan - TMW32/11

Praview Каталог насосов Wilo для бытового применения: отопление, водоснабжение, водоотведение
Обзор высокоэффективных циркуляционных насосов Wilo для систем отопления, водоснабжения и водоотведения. Информация для продавцов и монтажников.
Praview Wilo-Drain TM 32, TMW 32, TMR 32 Pam Rendam: Arahan Pemasangan dan Operasi
Manual pemasangan dan pengendalian yang komprehensif untuk pam saliran dan air kumbahan Wilo-Drain TM 32, TMW 32, dan TMR 32. Ketahui tentang ciri, aplikasi, keselamatan, pemasangan dan penyelenggaraan.
Praview Wilo-Drain TS/TSW 32 Installation and Operating Instructions
This document provides essential installation and operating instructions for the Wilo-Drain TS/TSW 32 submersible pump. It covers critical safety information, detailed product specifications, application guidelines, step-by-step installation procedures, commissioning steps, operational advice, maintenance recommendations, and proper disposal methods for domestic sewage and drainage applications.
Praview Wilo Submersible Motor Pumps: Installation and Operating Instructions
Detailed installation and operating instructions for Wilo submersible motor pumps, including models like Wilo-EMU, Wilo-Sub TWI, and Wilo-Actun ZETOS-K. Covers safety, product description, transport, installation, startup, maintenance, shutdown, and troubleshooting.
Praview Wilo-EMU FA + FK 17.1, FK 202, FK 34, FK 42 Installation and Operating Instructions
This document provides comprehensive installation and operating instructions for the Wilo-EMU FA and FK series submersible sewage pumps, including models FK 17.1, FK 202, FK 34, and FK 42. It covers essential safety guidelines, product details, installation procedures, commissioning steps, maintenance, and troubleshooting for reliable operation.
Praview Wilo-Drain TC 40 Installation and Operating Instructions
Comprehensive installation and operating instructions for the Wilo-Drain TC 40 submersible pump, covering safety, assembly, electrical and hydraulic connections, commissioning, and troubleshooting. Includes product specifications and service information.