Intermatic 2T2502GA

Intermatic 2T2502GA Pool/Spa Plastic Enclosure Timer Instruction Manual

Model: 2T2502GA

pengenalan

This manual provides essential information for the proper installation, operation, and maintenance of the Intermatic 2T2502GA Pool/Spa Plastic Enclosure. This enclosure is designed to house compatible Intermatic T100 series time switches, offering protection in various environmental conditions.

Produk Selesaiview

The Intermatic 2T2502GA is a durable, rainproof plastic enclosure specifically engineered for pool and spa timer applications. Its robust construction ensures longevity and protection for internal electrical components.

  • Bahan: Heavy-duty industrial grade plastic, beige finish.
  • Penilaian Alam Sekitar: NEMA 3R rated for both indoor and outdoor installations, providing protection against rain, sleet, and external ice formation.
  • Pencegahan Karat: Constructed from plastic to prevent rust, making it ideal for humid or wet environments.
  • Keserasian: Designed to house Intermatic T100 series time switches.
  • Kalah mati: Features combination 0.5 and 0.75 inch nominal knockouts (one on the back, one on each side, and two on the bottom) for wiring convenience.
Intermatic 2T2502GA Plastic Enclosure, closed front view

Rajah 1: Depan view of the Intermatic 2T2502GA Plastic Enclosure in its closed position. This image displays the beige finish and the Intermatic logo.

Maklumat Keselamatan

WARNING: Risk of electric shock. Installation and servicing must be performed by qualified personnel only.

  • Always disconnect power at the circuit breaker before installing or servicing the enclosure or any internal components.
  • Pastikan semua pendawaian mematuhi kod elektrik nasional dan tempatan.
  • This plastic enclosure does not provide grounding for internal components. Proper grounding of the time switch and associated wiring must be established independently according to electrical codes.
  • Do not exceed the maximum electrical ratings of the time switch installed within the enclosure.

Pemasangan dan Persediaan

  1. Lokasi Pemasangan: Select a suitable indoor or outdoor location that is easily accessible for servicing and protected from physical damage. Ensure the surface is flat and capable of supporting the enclosure's weight.
  2. Memasang Kandang:
    • Buka pintu kandang.
    • Use appropriate screws or fasteners (not included) to secure the enclosure to the mounting surface through the designated mounting holes.
  3. Preparing Knockouts:
    • Identify the required knockout locations (back, sides, bottom) for conduit entry.
    • Carefully remove the desired knockouts using a screwdriver and hammer. Exercise caution to avoid cracking the plastic.
    • Install appropriate conduit connectors and conduits.
  4. Installing the Time Switch:
    • The enclosure is designed for tool-free installation of compatible Intermatic T100 series time switches. The timer mechanism snaps into proprietary clips inside the box.
    • Refer to the specific instruction manual for your Intermatic T100 series time switch for detailed wiring instructions.
    • Pastikan semua sambungan elektrik kukuh dan berpenebat dengan betul.
  5. Pembumian: As this is a plastic enclosure, it does not provide an inherent ground path. Ensure that the time switch and all associated wiring are properly grounded according to local electrical codes. This may involve using a separate grounding conductor.
  6. Menutup Kandang: Once installation and wiring are complete, securely close the enclosure door. The door features a tongue-in-groove design for a rainproof seal.
Intermatic 2T2502GA Plastic Enclosure, open view menunjukkan bahagian dalam

Rajah 2: Dalaman view of the Intermatic 2T2502GA Plastic Enclosure with the door open. This image shows the internal mounting clips for the time switch and the knockout locations.

Penyelenggaraan

The Intermatic 2T2502GA enclosure requires minimal maintenance to ensure its protective function.

  • Pembersihan: Periodically clean the exterior of the enclosure with a damp kain untuk menghilangkan kotoran dan serpihan. Elakkan pembersih yang kasar.
  • Pemeriksaan: Regularly inspect the enclosure for any signs of physical damage, such as cracks, loose hinges, or a compromised latch. Ensure the door closes securely to maintain its rainproof rating.
  • Integriti Meterai: Verify that the tongue-in-groove seal around the door remains intact and free of debris to prevent water ingress.

Menyelesaikan masalah

This section addresses common issues related to the enclosure itself. For issues with the time switch, refer to its specific manual.

MasalahKemungkinan PuncaPenyelesaian
Water inside enclosureDoor not fully closed; damaged seal; improperly installed conduit fittings.Ensure door is latched securely. Inspect door seal for damage and replace if necessary. Verify conduit fittings are tight and sealed.
Enclosure door does not close securelyDamaged latch or hinges; obstruction.Inspect latch and hinges for damage. Clear any obstructions. If damaged, the enclosure may need replacement.
Plastik retakPhysical impact; improper knockout removal.A cracked enclosure compromises its NEMA 3R rating. Replace the enclosure immediately to maintain protection.

Spesifikasi

  • model: 2T2502GA
  • Jenama: Intermatik
  • Bahan: Heavy-duty Industrial Grade Plastic
  • Selesai: Beige
  • Penilaian Alam Sekitar: NEMA 3R (Rainproof)
  • Dimensi (H x W x D): 9-3/8 inches (23.8 cm) x 5-1/2 inches (14.0 cm) x 3-5/8 inches (9.2 cm)
  • Kalah mati: Combination 0.5 and 0.75 inch nominal (one back, two sides, two bottom)
  • Keserasian: Intermatic T100 series time switches

Waranti dan Sokongan

Waranti: This product is covered by a 1-year warranty for replacement of the unit. Labor costs are not included.

For technical support or warranty claims, please contact Intermatic customer service. Refer to the official Intermatic webtapak untuk maklumat hubungan semasa.

Note: Warranty terms are subject to change. Please refer to the official Intermatic warranty statement for the most up-to-date information.

Dokumen Berkaitan - 2T2502GA

Praview Arahan Pemasangan Kandang Suis Masa Kalis Hujan Plastik Intermatic
Panduan pemasangan terperinci untuk kandang suis masa kalis hujan plastik Intermatic, meliputi pemasangan bekas, sambungan saluran dan keperluan pembumian mengikut Kod Elektrik Negara.
Praview Cara Mengendalikan dan Menetapkan Pemasa Siri Intermatic T100
Panduan komprehensif untuk mengendalikan dan menetapkan pemasa mekanikal siri Intermatic T100, termasuk model T101, T103, T104, T105 dan T106. Ketahui tentang spesifikasi pemasa, langkah berjaga-jaga keselamatan, menetapkan triper HIDUP/MATI, menggunakan penggantian manual dan mencari sumber untuk menyelesaikan masalah dan alat ganti.
Praview Panduan Pemasangan dan Pengaturcaraan Suis Pemasa Pencahayaan Intermatic EJ341C/EJ343C
Arahan terperinci untuk memasang dan memprogram suis pemasa pencahayaan Intermatic EJ341C (Kutub Tunggal) dan EJ343C (Tiga Hala). Meliputi persediaan, kawalan, kaedah pengaturcaraan, penyelesaian masalah dan spesifikasi.
Praview Panduan Pemasangan dan Pengendalian Pemasa Undur Dalam Dinding Elektronik Intermatic EI200
Panduan terperinci untuk memasang dan mengendalikan pemasa undur elektronik dalam dinding Intermatic EI200. Ciri-cirinya termasuk julat masa 5-30 minit, mod HOLD berterusan dan penarafan untuk motor tujuan umum 15A, tungsten 1000W dan 1/4 HP. Termasuk maklumat waranti.
Praview Kawalan Pemasa Elektronik Intermatic ET8215C - Data Teknikal
Spesifikasi teknikal terperinci untuk Kawalan Pemasa Elektronik Intermatic ET8215C, kawalan elektronik 2 litar 7 hari astronomi yang sesuai untuk aplikasi 120-277 VAC dalam kandang logam tertutup.
Praview Suis Pemasa Mekanikal T173 T170 Intermatik - 24 Jam, 125V, 5HP
Spesifikasi terperinci untuk Suis Pemasa Mekanikal T173 T170 Intermatik. Mempunyai tetapan 24 jam, 125 VAC, rating motor 5 HP, 2NO DPST kenalan dan penutup NEMA 1. Sesuai untuk aplikasi komersil, perindustrian, kediaman, luaran dan HVACR.