1. Pengenalan

This manual provides instructions for the safe installation, operation, and maintenance of the Leviton 8200-LW 15-Amp, 125-Volt, Hospital Grade Duplex Receptacle. Please read these instructions thoroughly before beginning installation and retain them for future reference.

Leviton 8200-LW 15-Amp 125-Volt Hospital Grade Duplex Receptacle, White

Imej 1: Depan view of the Leviton 8200-LW Hospital Grade Duplex Receptacle in White.

2. Maklumat Keselamatan Penting

AMARAN: UNTUK MENGELAK KEBAKARAN, KEJUTAN ATAU KEMATIAN; MATIKAN KUASA PADA PEMUTUS LITAR ATAU FIUS DAN UJI KUASA ITU DIMATIKAN SEBELUM PENDAWAIAN!

3. Kandungan Pakej

The package for the Leviton 8200-LW Duplex Receptacle typically includes:

4. Spesifikasi Produk

Nombor Model: 8200-LW
Amppemadaman: 15 Amps
Voltage: 125 Volt
Konfigurasi: 5-15R
Pendawaian: 3-Wire, Self-Grounding (Back and Side Wiring)
Tiang: 2-Tiang
Bahan: Nylon (Body/Face)
warna: putih
Kelulusan: UL, CSA C22.2, NOM 057
Jenis: Heavy Duty, Hospital Grade

5. Persediaan dan Pemasangan

Alat yang Diperlukan: Screwdriver (Phillips and/or Flathead), Wire Strippers, Electrical Tape, Voltage Penguji.

  1. Matikan Kuasa: Locate the circuit breaker or fuse that controls the outlet you are replacing or installing. Turn off the power and verify it is off using a voltage penguji.
  2. Keluarkan Bekas Lama (jika berkenaan): Unscrew the wall plate and then the mounting screws holding the old receptacle in the electrical box. Carefully pull the old receptacle out of the box.
  3. Putuskan Sambungan Wayar: Note the position of each wire before disconnecting. Typically:
    • Green or Bare Copper Wire: Wayar bawah tanah.
    • Kawat Putih: Kawat neutral.
    • Black or Red Wire: Hot (live) wire.
    Loosen the terminal screws and remove the wires.
  4. Sediakan Wayar: If necessary, strip approximately 1/2 inch (12.7 mm) of insulation from the ends of the wires. Ensure the wire ends are clean and straight.
  5. Connect Wires to New Receptacle: The Leviton 8200-LW supports both back and side wiring.
    • Kawat Tanah (Tembaga Hijau atau Kosong): Connect to the green hexagonal ground screw.
    • Kawat Neutral (Putih): Connect to the silver terminal screws.
    • Hot Wire (Black or Red): Connect to the brass terminal screws.

    For Side Wiring: Loop the wire clockwise around the screw terminal and tighten securely. Ensure no bare wire is exposed outside the terminal.

    For Back Wiring: Insert the stripped wire end into the appropriate hole on the back of the receptacle and tighten the corresponding screw on the side. The V-shaped, serrated back-wiring clamps ensure superior contact.

  6. Bekas Selamat: Carefully fold the wires into the electrical box. Insert the new receptacle into the box and secure it with the mounting screws.
  7. Pasang Plat Dinding: Attach the wall plate over the receptacle.
  8. Pulihkan Kuasa: Turn the power back on at the circuit breaker or fuse.
  9. Ujian: Test the receptacle with a known working device.

6. Arahan Operasi

The Leviton 8200-LW Duplex Receptacle functions as a standard electrical outlet. Once properly installed and powered, simply insert the plug of your electrical device into one of the two available outlets. Ensure the plug is fully inserted for a secure connection.

7. Penyelenggaraan

8. Penyelesaian masalah

Masalah Kemungkinan Punca Penyelesaian
Tidak ada kuasa di wadah. Circuit breaker tripped or fuse blown. Loose wiring connection. Check and reset the circuit breaker or replace the fuse. Turn off power and check all wire connections for tightness.
Plug feels loose in the receptacle. Worn receptacle contacts (unlikely for new hospital-grade). Incorrect plug type. Ensure the plug is fully inserted. If the issue persists with multiple devices, consult a qualified electrician for inspection.
Receptacle is hot to the touch. Overload on the circuit. Loose connection. Faulty device. Immediately disconnect power. Reduce the load on the circuit. Have a qualified electrician inspect the wiring and device.

9. Waranti dan Sokongan

Leviton products are manufactured to the highest quality standards. For specific warranty information and customer support, please refer to the documentation included with your purchase or visit the official Leviton webtapak. Simpan resit pembelian anda sebagai bukti pembelian.

Leviton Customer Support:

Dokumen Berkaitan - 8200-LW

Praview Outlet GFCI Leviton dengan Manual Pemasangan dan Operasi Port USB
Panduan komprehensif untuk memasang dan mengendalikan Outlet GFCI Leviton dengan Port USB, termasuk arahan pendawaian, amaran keselamatan, prosedur ujian dan maklumat waranti.
Praview Installing and Testing Leviton Smart GFCI Outlet: A Comprehensive Guide
Step-by-step instructions for installing and testing Leviton Smart GFCI outlets (models D2GF1, D2GF2). Learn about GFCI functionality, wiring, troubleshooting, and safety precautions.
Praview Panduan Pemasangan dan Pengujian Bekas GFCI Leviton SmartlockPro
Panduan komprehensif untuk memasang dan menguji soket Pemisah Litar Kerosakan Tanah (GFCI) Leviton SmartlockPro. Meliputi langkah berjaga-jaga keselamatan, pendawaian, penyelesaian masalah dan ciri produk.
Praview Panduan Pemasangan dan Pengujian Bekas Leviton GFCI
Panduan komprehensif tentang cara memasang dan menguji Bekas Leviton SmartLock Pro GFCI, termasuk arahan pendawaian, langkah berjaga-jaga keselamatan dan petua penyelesaian masalah.
Praview Leviton Commercial & Industrial Grade Switches Selection Guide
A comprehensive selection guide from Leviton detailing commercial and industrial grade switches, including toggle, Decora Plus, Lev-lok, antimicrobial, and specialty switch types with application details and wiring diagrams.
Praview Leviton GFNT1-DIN/GFNT2-DIN DIN Panduan Pemasangan Bekas Rel GFCI
Panduan komprehensif untuk memasang dan menguji Bekas GFCI GFNT1-DIN dan GFNT2-DIN DIN Rail Mount Leviton, termasuk arahan pendawaian, langkah berjaga-jaga keselamatan dan penyelesaian masalah.