1. Pengenalan
This manual provides instructions for the safe installation, operation, and maintenance of the Leviton 8200-LW 15-Amp, 125-Volt, Hospital Grade Duplex Receptacle. Please read these instructions thoroughly before beginning installation and retain them for future reference.
Imej 1: Depan view of the Leviton 8200-LW Hospital Grade Duplex Receptacle in White.
2. Maklumat Keselamatan Penting
AMARAN: UNTUK MENGELAK KEBAKARAN, KEJUTAN ATAU KEMATIAN; MATIKAN KUASA PADA PEMUTUS LITAR ATAU FIUS DAN UJI KUASA ITU DIMATIKAN SEBELUM PENDAWAIAN!
- Installation must be performed by a qualified electrician in accordance with all national and local electrical codes and regulations.
- Always disconnect power at the main service panel before working with electrical wiring.
- Use only copper or copper-clad wire. Do not use aluminum wire with this device.
- Pastikan semua sambungan wayar selamat dan terlindung dengan betul.
- Peranti ini direka untuk kegunaan dalaman sahaja.
- Jangan melebihi penarafan elektrik peranti yang ditentukan.
3. Kandungan Pakej
The package for the Leviton 8200-LW Duplex Receptacle typically includes:
- One (1) Leviton 8200-LW 15-Amp, 125-Volt, Hospital Grade Duplex Receptacle (White)
4. Spesifikasi Produk
| Nombor Model: | 8200-LW |
| Amppemadaman: | 15 Amps |
| Voltage: | 125 Volt |
| Konfigurasi: | 5-15R |
| Pendawaian: | 3-Wire, Self-Grounding (Back and Side Wiring) |
| Tiang: | 2-Tiang |
| Bahan: | Nylon (Body/Face) |
| warna: | putih |
| Kelulusan: | UL, CSA C22.2, NOM 057 |
| Jenis: | Heavy Duty, Hospital Grade |
5. Persediaan dan Pemasangan
Alat yang Diperlukan: Screwdriver (Phillips and/or Flathead), Wire Strippers, Electrical Tape, Voltage Penguji.
- Matikan Kuasa: Locate the circuit breaker or fuse that controls the outlet you are replacing or installing. Turn off the power and verify it is off using a voltage penguji.
- Keluarkan Bekas Lama (jika berkenaan): Unscrew the wall plate and then the mounting screws holding the old receptacle in the electrical box. Carefully pull the old receptacle out of the box.
- Putuskan Sambungan Wayar: Note the position of each wire before disconnecting. Typically:
- Green or Bare Copper Wire: Wayar bawah tanah.
- Kawat Putih: Kawat neutral.
- Black or Red Wire: Hot (live) wire.
- Sediakan Wayar: If necessary, strip approximately 1/2 inch (12.7 mm) of insulation from the ends of the wires. Ensure the wire ends are clean and straight.
- Connect Wires to New Receptacle: The Leviton 8200-LW supports both back and side wiring.
- Kawat Tanah (Tembaga Hijau atau Kosong): Connect to the green hexagonal ground screw.
- Kawat Neutral (Putih): Connect to the silver terminal screws.
- Hot Wire (Black or Red): Connect to the brass terminal screws.
For Side Wiring: Loop the wire clockwise around the screw terminal and tighten securely. Ensure no bare wire is exposed outside the terminal.
For Back Wiring: Insert the stripped wire end into the appropriate hole on the back of the receptacle and tighten the corresponding screw on the side. The V-shaped, serrated back-wiring clamps ensure superior contact.
- Bekas Selamat: Carefully fold the wires into the electrical box. Insert the new receptacle into the box and secure it with the mounting screws.
- Pasang Plat Dinding: Attach the wall plate over the receptacle.
- Pulihkan Kuasa: Turn the power back on at the circuit breaker or fuse.
- Ujian: Test the receptacle with a known working device.
6. Arahan Operasi
The Leviton 8200-LW Duplex Receptacle functions as a standard electrical outlet. Once properly installed and powered, simply insert the plug of your electrical device into one of the two available outlets. Ensure the plug is fully inserted for a secure connection.
7. Penyelenggaraan
- Pembersihan: To clean the receptacle, ensure power is off at the circuit breaker. Wipe the surface with a soft, damp kain. Jangan gunakan pembersih atau pelarut yang melelas.
- Pemeriksaan: Periodically inspect the receptacle for any signs of damage, such as cracks, discoloration, or loose connections. If any damage is observed, disconnect power and have the device inspected or replaced by a qualified electrician.
- "Green Dot" Marking: This hospital-grade receptacle features a permanent "Green Dot" marking on its face, indicating its compliance with hospital-grade standards for enhanced durability and reliability.
8. Penyelesaian masalah
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Tidak ada kuasa di wadah. | Circuit breaker tripped or fuse blown. Loose wiring connection. | Check and reset the circuit breaker or replace the fuse. Turn off power and check all wire connections for tightness. |
| Plug feels loose in the receptacle. | Worn receptacle contacts (unlikely for new hospital-grade). Incorrect plug type. | Ensure the plug is fully inserted. If the issue persists with multiple devices, consult a qualified electrician for inspection. |
| Receptacle is hot to the touch. | Overload on the circuit. Loose connection. Faulty device. | Immediately disconnect power. Reduce the load on the circuit. Have a qualified electrician inspect the wiring and device. |
9. Waranti dan Sokongan
Leviton products are manufactured to the highest quality standards. For specific warranty information and customer support, please refer to the documentation included with your purchase or visit the official Leviton webtapak. Simpan resit pembelian anda sebagai bukti pembelian.
Leviton Customer Support:
- Visit Leviton Support Webtapak
- Rujuk maklumat hubungan yang diberikan pada pembungkusan produk.