Intermatic T104P

Intermatic T104P 24-Hour Mechanical Time Switch User Manual

Brand: Intermatic | Model: T104P

1. Pengenalan

The Intermatic T104P is a heavy-duty 24-hour mechanical time switch designed for automatic control of electrical loads. This device provides reliable scheduling for various applications, offering up to 12 ON/OFF operations daily. Its robust plastic enclosure is suitable for both indoor and outdoor installations, providing protection against environmental elements.

Key features include direct 24-hour control, a minimum ON/OFF time of one hour, and a manual override function for temporary control adjustments.

2. Maklumat Keselamatan

WARNING: Risk of Electric Shock. Disconnect power at the circuit breaker or fuse before installing or servicing this time switch. Failure to do so may result in serious injury or death.

3. Kandungan Pakej

Sahkan bahawa semua item terdapat dalam pakej:

4. Persediaan dan Pemasangan

4.1 Mounting the Time Switch

The T104P features a NEMA 3R rated plastic enclosure, suitable for both indoor and outdoor mounting. Choose a location that is easily accessible for programming and maintenance, and protected from direct impact.

  1. Buka pintu kandang.
  2. Use appropriate screws or mounting hardware (not included) to secure the enclosure to a flat, stable surface through the designated mounting holes.
  3. Ensure the enclosure is level to allow for proper operation of the mechanical timer.

4.2 Arahan Pendawaian

Refer to the internal wiring diagram and the following steps for proper electrical connection. Always ensure power is disconnected before proceeding.

Dalaman view of Intermatic T104P mechanical time switch showing the yellow dial, manual lever, and wiring terminals.

Rajah 1: Dalaman view of Intermatic T104P mechanical time switch showing the yellow dial, manual lever, and wiring terminals. This image displays the internal components of the Intermatic T104P time switch, including the 24-hour dial for setting time, the manual ON/OFF lever, and the clearly labeled LINE and LOAD wiring terminals. A caution label regarding power disconnection and wire types is visible.

  1. Putuskan Kuasa: Turn off power at the main circuit breaker or fuse panel before beginning any wiring.
  2. Access Terminals: The insulator covering the wiring terminals must be lifted and swung out of the way to access the connections. DO NOT REMOVE THIS INSULATOR.
  3. Connect Line Wires: Connect the incoming power supply wires (LINE) to the terminals labeled 'LINE'. This time switch is DPST (Double Pole Single Throw), meaning it controls two separate hot lines.
  4. Sambungkan Wayar Beban: Connect the wires leading to the electrical load (e.g., pump, lighting) to the terminals labeled 'LOAD'.
  5. Pembumian: Ensure the time switch is properly grounded according to local electrical codes.
  6. Wayar Selamat: Pastikan semua sambungan wayar adalah ketat dan selamat.
  7. Replace Insulator: Swing the insulator back into its original position, covering the wiring terminals.
  8. Tutup Kandang: Tutup dan kuncikan pintu kandang.
  9. Pulihkan Kuasa: Turn power back on at the main circuit breaker or fuse panel.
sebelah view of Intermatic T104P mechanical time switch with the gray plastic enclosure open, revealing the internal mechanism.

Rajah 2: sebelah view of Intermatic T104P mechanical time switch with the gray plastic enclosure open, revealing the internal mechanism. This image shows the Intermatic T104P time switch with its gray plastic enclosure open, providing a view of the internal mechanical timer and the wiring compartment. The NEMA 3R rated enclosure is designed for both indoor and outdoor use.

5. Arahan Operasi

5.1 Menetapkan Masa Semasa

To set the current time, rotate the yellow dial clockwise until the current time of day aligns with the small arrow located at the top of the dial. Ensure to differentiate between AM and PM hours as indicated on the dial.

5.2 Menetapkan Masa HIDUP/MATI

The T104P uses trippers to set the ON and OFF times. The unit comes with one ON tripper (green) and one OFF tripper (red).

  1. Install ON Tripper: Locate the green ON tripper. Push it onto the outer edge of the yellow dial at the desired time you want the connected load to turn ON.
  2. Install OFF Tripper: Locate the red OFF tripper. Push it onto the outer edge of the yellow dial at the desired time you want the connected load to turn OFF.
  3. Kitaran Tambahan: The time switch supports up to 12 ON/OFF operations per day. Additional trippers can be purchased separately if more cycles are required. Each ON/OFF cycle requires one green ON tripper and one red OFF tripper.
  4. Selang Minimum: The minimum ON/OFF time interval is one hour. Ensure there is at least one hour between an ON and OFF tripper.

5.3 Pembatalan Manual

The time switch includes a manual override lever for temporary control of the connected load without affecting the programmed schedule.

6. Penyelenggaraan

The Intermatic T104P is designed for minimal maintenance. However, periodic checks can ensure optimal performance and longevity.

7. Penyelesaian masalah

MasalahKemungkinan PuncaPenyelesaian
Beban tidak HIDUP/MATI pada waktu yang diprogramkan.
  • Tetapan masa semasa yang salah.
  • Trippers incorrectly placed or missing.
  • Penggantian manual telah digunakan.
  • Tiada kuasa pada suis masa.
  • Verify and adjust the current time.
  • Check tripper placement and ensure they are securely attached.
  • Ensure manual override lever is in the automatic position.
  • Check circuit breaker/fuse and wiring connections.
Time switch dial is not rotating.
  • Tiada kuasa pada suis masa.
  • Masalah mekanikal dalaman.
  • Check circuit breaker/fuse and wiring connections.
  • If power is present and dial still does not rotate, the unit may require replacement.
Enclosure door does not close properly.
  • Obstruction or damage to hinges/latch.
  • Inspect for debris or damage. Clear any obstructions.

8. Spesifikasi

Depan view of the Intermatic T104P mechanical time switch with its gray plastic enclosure closed, showing the Intermatic logo.

Rajah 3: Depan view of the Intermatic T104P mechanical time switch with its gray plastic enclosure closed, showing the Intermatic logo. This image presents the Intermatic T104P time switch with its durable gray plastic enclosure closed, suitable for protecting the internal components from environmental elements. The Intermatic brand logo is embossed on the front.

CiriPerincian
ModelT104P
taip24-Hour Mechanical Time Switch
Voltage208-277 VAC
Kekerapan60 Hz
Bilangan Tiang2 (DPST)
Amppemadam40 Amps
Horsepower (HP) Rating2 HP @ 120V, 5 HP @ 240V
Jenis KepunganPlastic, NEMA 3R (Indoor/Outdoor)
Masa HIDUP/MATI Minimum1 Jam
Maximum ON/OFF Cycles12 setiap hari
Dimensi (H x W x D)9.43" x 5.5" x 3.81"
Berat Barang2 paun
bahanPadat
warnaKelabu

9. Waranti dan Sokongan

For warranty information, please refer to the manufacturer's official documentation included with your product or visit the Intermatic brand store atau pegawai mereka webtapak.

If you require technical assistance or have questions regarding the operation or installation of your Intermatic T104P time switch, please contact Intermatic customer support directly.

Dokumen Berkaitan - T104P

Praview Suis Masa Dail 24 Jam Intermatic T103: Manual Pemasangan dan Operasi
Panduan terperinci untuk Suis Masa Dail 24 Jam Intermatic T103, meliputi spesifikasi, amaran keselamatan, arahan pendawaian, pengaturcaraan dan operasi. Sesuai untuk kegunaan dalaman dengan kuasa 120/208/240 VAC.
Praview Suis Masa Elektromekanikal Siri Intermatic T170, T1400 & T1800
Butiran komprehensif tentang Suis Masa Elektromekanikal 24 Jam Siri Intermatic T170, T1400 dan T1800, meliputi ciri, spesifikasi, penarafan, variasi model dan gambar rajah pendawaian untuk aplikasi komersial, perindustrian dan kediaman.
Praview Suis Masa Dail 24 Jam Intermatic T105: Panduan Pemasangan, Pendawaian dan Operasi
Panduan komprehensif untuk suis masa dail mekanikal 24 jam Intermatic T105. Meliputi spesifikasi model, amaran keselamatan, arahan pendawaian untuk pelbagai konfigurasi (SPNO, SPNC, SPDT), prosedur pengaturcaraan dan operasi manual. Termasuk jadual terperinci penarafan elektrik dan cadangan tolok wayar.
Praview Intermatic T104 24-Hour Dial Time Switch - Specifications and Instructions
Comprehensive guide for the Intermatic T104 24-hour dial time switch, detailing its specifications, electrical ratings, safety warnings, wiring instructions, programming procedures, and operating guidelines. Includes technical data and troubleshooting tips.
Praview Intermatic GM40AV Series Electromechanical Commercial Time Switch: Installation and Operation Manual
Comprehensive installation, operation, and programming guide for the Intermatic GM40AV Series electromechanical commercial time switches. Includes electrical ratings, wiring diagrams, and warranty information.
Praview Manual Arahan Suis Masa Elektronik Intermatic GMXFM1
Manual arahan untuk suis masa elektronik Intermatic GMXFM1, merangkumi langkah berjaga-jaga keselamatan, simbol, persediaan awal, pengaturcaraan, tetapan masa, pelarasan penjimatan siang, mod operasi dan maklumat waranti.