GREISINGER 600437

Logo GREISINGER

The GREISINGER logo, representing the manufacturer of this oxygen tester.

GREISINGER GOX 100 Tester for the Air User Manual

Model: GOX 100 (Part Number: 600437)

1. Pengenalan

The GREISINGER GOX 100 is a compact and precise measuring instrument designed for atmospheric oxygen measurements. It is suitable for a wide range of applications, including scuba diving, workplace safety, and air conditioning and ventilation technology. This manual provides essential information for the proper setup, operation, and maintenance of your GOX 100 device.

2. Maklumat Keselamatan

3. Kandungan Pakej

Sahkan bahawa semua item terdapat dalam pakej:

4. Persediaan

4.1 Pemasangan Bateri

  1. Cari petak bateri di bahagian belakang peranti.
  2. Buka penutup petak bateri.
  3. Insert a 9V block battery, ensuring correct polarity.
  4. Tutup penutup petak bateri dengan selamat.

4.2 Sambungan Sensor

The oxygen sensor is typically pre-connected to the GOX 100 via a cable. Ensure the connection is firm and secure.

GREISINGER GOX 100 with sensor displaying 20.9% O2

The GREISINGER GOX 100 device with its attached oxygen sensor, displaying an oxygen reading of 20.9%.

5. Arahan Operasi

5.1 Menghidupkan/Mematikan

5.2 Mengambil Pengukuran

5.3 MIN/MAX Value Recall

5.4 Automatic Off Function

The GOX 100 features an adjustable automatic off function to conserve battery life. If enabled, the device will power off after a period of inactivity. Refer to the full manual for instructions on how to adjust or disable this feature.

6. Penentukuran

Regular calibration ensures the accuracy of your GOX 100. The device supports easy calibration in ambient air.

  1. Ensure the device and sensor are at a stable temperature.
  2. Place the sensor in fresh ambient air, away from any sources of gas or fumes.
  3. Tekan dan tahan butang cal button until the display indicates calibration mode.
  4. The device will automatically adjust its reading to 20.9% or 21.0% oxygen, which is the approximate concentration of oxygen in normal ambient air.
  5. Once calibration is complete, the device will return to normal measurement mode.
GREISINGER GOX 100 with sensor displaying 21.0% O2

The GREISINGER GOX 100 displaying 21.0% O2, indicating a successful calibration in ambient air.

7. Penyelenggaraan

7.1 Penggantian Sensor

The GOX 100 features a convenient, easily replaceable sensor element. Over time, the sensor's performance may degrade. When replacement is necessary:

  1. Matikan peranti.
  2. Carefully disconnect the old sensor from the cable.
  3. Connect the new, compatible GREISINGER oxygen sensor.
  4. Lakukan penentukuran seperti yang diterangkan dalam Bahagian 6.

7.2 Pembersihan

8. Penyelesaian masalah

MasalahKemungkinan Punca / Penyelesaian
Peranti tidak dihidupkanPeriksa pemasangan bateri dan cas. Gantikan bateri jika perlu.
Bacaan tidak tepatPerform calibration (Section 6). Check sensor for damage or contamination. Sensor may need replacement.
Display shows 'Err' or similarIndicates a sensor error or malfunction. Try recalibrating. If issue persists, sensor may need replacement or contact support.
Automatic off too soon/not at allAdjust the automatic off settings (refer to full manual).

9. Spesifikasi Teknikal

ParameterNilai
Julat Pengukuran0 - 100 % Oxygen
Resolusi0.1 %
Ketepatan Pengukuran0 % (Note: This likely refers to a specific condition or a typo in source data, typical accuracy is usually +/- a percentage point)
Bekalan KuasaBateri blok 9V
Jenis PerlindunganIP65
Dimensi (H x W)106 mm x 67 mm
Berat badan150 g (device only, approx.)
Cable Length (sensor)0.7 m
Thermal CompensationAutomatik

10. Waranti dan Sokongan

GREISINGER products are manufactured to high quality standards. This product comes with a standard manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official GREISINGER webtapak.

For technical support, troubleshooting assistance, or to inquire about replacement parts and sensors, please contact GREISINGER customer service through their official webtapak atau maklumat hubungan yang diberikan dalam dokumentasi produk anda.

Dokumen Berkaitan - 600437

Praview Manual Pengendalian Peranti Pengukur Oksigen GREISINGER GOX 100
Manual pengendalian yang komprehensif untuk peranti pengukur oksigen GREISINGER GOX 100, memperincikan penggunaan yang dimaksudkan, langkah berjaga-jaga keselamatan, prosedur operasi, penentukuran, mesej ralat dan spesifikasi teknikal.
Praview Manual Pengendalian GREISINGER GE xxx: Elektrod pH
Manual pengendalian yang komprehensif untuk elektrod pH siri GREISINGER GE xxx, meliputi keselamatan, asas, pengukuran, penentukuran, penyelenggaraan, pemilihan dan spesifikasi. Termasuk panduan terperinci untuk pengukuran pH yang tepat.
Praview G 1910-02 Monitor CO2 Kompak dengan Manual Pengendalian Penggera
Manual pengendalian untuk Monitor CO2 Kompak G 1910-02 dengan Penggera, memperincikan ciri, arahan keselamatan, operasi, penyelenggaraan dan spesifikasi teknikalnya.
Praview GREISINGER EBUW 232 EASYBUS Protocol Converter Operating Manual
Operating manual for the GREISINGER EBUW 232 EASYBUS protocol converter, detailing its specifications, general information, and safety requirements.
Praview Manual Pengguna Meter Tekanan Tangan Greisinger GMH 3111
Manual pengguna untuk meter tekanan pegang tangan Greisinger GMH 3111, meliputi keperluan keselamatan, operasi, penyelenggaraan, konfigurasi dan spesifikasi untuk digunakan dengan penderia tekanan GMSD, GMXD, MSD dan MXD.
Praview Manual Pengendalian GREISINGER GMH 5430: Kekonduksian, Kerintangan, TDS, Meter Kemasinan
Manual pengendalian yang komprehensif untuk peranti pengukur kekonduksian kalis air GREISINGER GMH 5430. Meliputi ciri, operasi, penentukuran, penyelesaian masalah dan spesifikasi.