The Wayne CWS100 1-horsepower shallow well jet pump is designed for wells up to 90-feet deep. It is capable of pumping up to 560 gallons per hour at a 5-foot depth when operating at 50 PSI. This pump is built with a durable cast iron volute and features a dedicated priming port for easy filling.

Image: The Wayne CWS100 Convertible Well Pump, showcasing its black cast iron body and motor assembly.
Ciri-ciri Utama
- Power and Flow: 1 HP motor with a maximum flow rate of 588 gallons per hour at 50 PSI.
- Sambungan: Features a 3/4 inch NPT discharge, 1-1/4 inch NPT suction, and 1 inch drive.
- Voltage: dwi jldtage (120V/240V) high-efficiency square flange motor, factory-set for 240V.
- Operasi automatik: Pressure switch pre-set at 30-50 PSI for reliable automatic operation.
- Pembinaan: Durable cast iron volute with a dedicated priming port for easy initial setup.
- Asal: Assembled in the US with foreign and domestic parts.
Arahan Persediaan
Proper installation is crucial for the optimal performance and longevity of your Wayne CWS100 pump. Ensure all local plumbing and electrical codes are followed. The pump is designed for shallow well applications up to 90 feet deep.
1. Site Selection and Mounting
Choose a dry, well-ventilated location as close to the well as possible. Mount the pump on a solid, level surface to minimize vibration and noise. Use appropriate bolts to secure the pump base.
2. Sambungan Paip
Connect the suction line (1-1/4 inch NPT) from the well to the pump's suction port. Connect the discharge line (3/4 inch NPT) from the pump to your household plumbing system. Ensure all connections are watertight using thread sealant. Consider increasing suction plumbing diameter or decreasing pipe friction for improved performance.
3. Pendawaian Elektrik
The pump is factory-set for 240V operation. If 120V operation is desired, consult the wiring diagram provided in the full user manual for proper conversion. Connect the pump to a dedicated, properly grounded electrical circuit with appropriate overcurrent protection. All electrical work should be performed by a qualified electrician.
4. Menyapu Pam
Before initial operation, the pump must be primed. Remove the priming plug from the dedicated priming port on the volute. Fill the pump casing and suction line completely with water until it overflows. Replace the priming plug securely. This step is critical for jet pump operation.
Arahan Operasi
Once properly installed and primed, the Wayne CWS100 pump operates automatically based on system pressure.
1. Permulaan Permulaan
After priming, restore power to the pump. The pump will start and build pressure. The pressure switch is pre-set to turn the pump on at 30 PSI and off at 50 PSI. Allow the pump to run until it reaches the cut-off pressure and shuts off automatically.
2. Operasi Biasa
The pump will cycle on and off as water is used and system pressure drops below the cut-in setting. Ensure there are no leaks in the plumbing system, as this can cause the pump to short cycle (turn on and off frequently).
3. Mematikan
For temporary shutdown, simply turn off the power to the pump at the circuit breaker. For extended periods of non-use, especially in freezing temperatures, drain the pump and plumbing lines completely to prevent damage.
Penyelenggaraan
Regular maintenance helps ensure the longevity and efficient operation of your well pump.
- Periksa Kebocoran: Periodically check all plumbing connections for leaks. Even small leaks can affect pump performance.
- Check Pressure Switch: Ensure the pressure switch is clean and free from debris. Do not attempt to adjust the factory-set pressure unless you are a qualified technician.
- Musim sejuk: In areas subject to freezing temperatures, drain the pump and all exposed plumbing lines completely before winter. This prevents damage from ice expansion.
- Pengudaraan Motor: Ensure the motor's ventilation openings are clear of obstructions to prevent overheating.
Menyelesaikan masalah
This section provides basic troubleshooting steps for common issues. For more complex problems, consult a qualified professional or refer to the complete user manual.
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Pump runs but no water or low pressure | Loss of prime, air leak in suction line, low well water level, clogged impeller. | Re-prime the pump. Check all suction line connections for leaks. Verify well water level. Inspect and clean impeller if accessible. |
| Pump short cycles (turns on/off frequently) | Waterlogged pressure tank, air leak in system, pressure switch malfunction. | Check pressure tank air charge. Inspect plumbing for leaks. Consult a technician for pressure switch issues. |
| Pam tidak bermula | No power, tripped circuit breaker, faulty motor, seized pump. | Check power supply and circuit breaker. Consult a qualified electrician or pump technician. |
Spesifikasi
| Atribut | Perincian |
|---|---|
| Jenama | Wayne |
| Nombor Model | CWS100 |
| Kuasa kuda | 1 HP |
| Kadar Aliran Maks | 588 gallons per hour (at 50 PSI) |
| Ketinggian Angkat Maks | Sehingga 90 kaki |
| Voltage | 120V/240V (Dua Voltage, factory set for 240V) |
| Saiz Pelepasan | NPT 3/4 inci |
| Saiz sedutan | 1-1/4 inci NPT |
| Saiz Pemacu | 1 inci |
| Tetapan Suis Tekanan | 30-50 PSI (pre-set) |
| bahan | Besi tuang |
| Berat Barang | 40 paun |
| Dimensi Produk | 14 x 9 x 8.75 inci |
| UPC | 040066105974 |
Maklumat Waranti
The Wayne CWS100 Convertible Well Pump comes with a Waranti terhad 3 tahun covering parts only. For specific terms and conditions, please refer to the official warranty documentation included with your product or contact Wayne customer support.
Sokongan dan Maklumat Lanjut
For detailed diagrams, advanced troubleshooting, or to purchase replacement parts, please refer to the complete user manual available as a PDF document. You can often find this on the manufacturer's official webtapak atau melalui peruncit tempat anda membeli produk tersebut.
For direct support, you may visit the official Wayne store or contact their customer service department.
Visit the Wayne Store on Amazon
A PDF version of the user manual is also available for download: Muat turun Manual Pengguna (PDF)