Amprobe SM-CAL1

AmpManual Pengguna Kalibrator Meter Bunyi robe SM-CAL1

Model: SM-CAL1

1. Pengenalan

The Amprobe SM-CAL1 is a precision sound meter calibrator designed to ensure the accuracy and reliability of your sound level measurements. This device generates two fixed sound pressure levels, 94 decibels (dB) and 114 dB, at a frequency of 1,000 hertz (Hz), allowing for precise calibration of sound meters with microphones up to 1/2 inch in diameter. Regular calibration is crucial for maintaining measurement integrity and compliance with relevant standards.

This manual provides detailed instructions for the proper use, maintenance, and troubleshooting of your SM-CAL1 Sound Meter Calibrator.

2. Maklumat Keselamatan

Please read and understand all safety instructions before operating the SM-CAL1. Failure to follow these guidelines may result in injury or damage to the device.

  • Do not expose the calibrator to extreme temperatures, humidity, or direct sunlight.
  • Elakkan daripada menjatuhkan atau meletakkan peranti kepada kesan yang kuat.
  • Do not attempt to open or modify the calibrator. Refer all servicing to qualified personnel.
  • Pastikan petak bateri ditutup rapat semasa operasi.
  • Buang bateri mengikut peraturan tempatan.

3. Kandungan Pakej

Sahkan bahawa semua item terdapat dalam pakej:

  • Amprobe SM-CAL1 Sound Meter Calibrator
  • One (1) 9V battery (installed)
  • Arahan Pengguna (manual ini)

4. Persediaan

4.1 Pemasangan Bateri

The SM-CAL1 comes with a 9V battery pre-installed. If replacement is needed:

  1. Cari penutup petak bateri di bahagian bawah unit.
  2. Tanggalkan penutup.
  3. Connect a new 9V battery, observing correct polarity.
  4. Gantikan penutup petak bateri dengan selamat.

4.2 Preparing for Calibration

Before calibrating your sound meter, ensure its microphone is clean and free of debris. The SM-CAL1 is designed to fit microphones with a diameter of up to 1/2 inch.

Amprobe SM-CAL1 Sound Meter Calibrator with power switch and display showing 94 114 OFF db at 1kHz, IEC 942 1988 CLASS 2, and Sound Calibrator.

Rajah 1: Amprobe SM-CAL1 Sound Meter Calibrator. The image shows the top face of the cylindrical calibrator, featuring the 'AMPROBE' logo, 'SM-CAL1' model number, a three-position slide switch labeled '94', 'OFF', and '114' (referring to dB levels), and text indicating 'db at 1kHz', 'IEC 942 1988 CLASS 2', and 'Sound Calibrator'. A red power indicator light is also visible.

5. Operasi

5.1 Calibrating a Sound Meter

  1. Gently insert the microphone of your sound level meter into the opening on the top of the SM-CAL1 calibrator. Ensure a snug fit to minimize sound leakage.
  2. Select the desired calibration level using the slide switch on the calibrator:
    • Slide to '94' for a 94 dB signal.
    • Slide to '114' for a 114 dB signal.
  3. Observe the reading on your sound level meter. Adjust your sound meter's calibration settings until its display matches the selected output level of the SM-CAL1 (either 94 dB or 114 dB). Refer to your sound meter's user manual for specific calibration adjustment procedures.
  4. Once calibration is complete, slide the switch to 'OFF' to conserve battery life.
  5. Carefully remove the sound meter's microphone from the calibrator.

5.2 Petunjuk Bateri Rendah

The SM-CAL1 is equipped with a low-battery indicator. When the battery voltage drops below a certain level, the indicator light will dim or not illuminate, signaling that the 9V battery needs to be replaced.

6. Penyelenggaraan

6.1 Pembersihan

To clean the exterior of the calibrator, use a soft, dry cloth. Do not use abrasive cleaners or solvents, as these may damage the casing atau komponen dalaman.

6.2 Penyimpanan

When not in use, store the SM-CAL1 in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, it is recommended to remove the 9V battery to prevent leakage.

6.3 Recalibration of the SM-CAL1

While the SM-CAL1 is designed for stable output, periodic verification of its accuracy by a certified calibration laboratory is recommended to ensure continued compliance with standards and optimal performance. The frequency of such recalibration depends on usage and regulatory requirements.

7. Penyelesaian masalah

MasalahKemungkinan PuncaPenyelesaian
No sound output / Power indicator offBateri mati atau tidak dipasang dengan betul.Gantikan bateri 9V, pastikan kekutuban yang betul.
Inaccurate calibration readings on sound meterMicrophone not properly seated; Calibrator needs recalibration; Sound meter issue.Ensure microphone is snugly fitted. Consider sending SM-CAL1 for professional recalibration. Check your sound meter's functionality.
Sound meter reading fluctuatesAmbient noise interference; Loose microphone connection.Perform calibration in a quiet environment. Re-seat the microphone firmly.

8. Spesifikasi

  • model: SM-CAL1
  • Output Sound Pressure Levels: 94 dB dan 114 dB
  • Kekerapan Output: 1,000 Hz (1 kHz)
  • Keserasian Mikrofon: Fits microphones up to 1/2 inch diameter
  • Ketepatan: Meets IEC 942 1988 Class 2 standards
  • Sumber Kuasa: One (1) 9V battery
  • Penunjuk Bateri Rendah: ya
  • Suhu Operasi: 0°C hingga 40°C (32°F hingga 104°F)
  • Suhu penyimpanan: -10°C hingga 50°C (14°F hingga 122°F)
  • Dimensions (H x D): Kira-kira 4.9 x 1.9 inci (125 x 48 mm)
  • Berat: Kira-kira 0.6 lb (285 g)
  • Pensijilan: CE compliant, ANSI, IEC standards

9. Waranti dan Sokongan

9.1 Maklumat Waranti

Amprobe products are warranted against defects in material and workmanship for a specified period from the date of purchase. For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official Ampjubah website. This warranty does not cover damage resulting from misuse, accident, neglect, alteration, contamination, or abnormal conditions of operation or handling.

9.2 Sokongan Pelanggan

Jika anda menghadapi sebarang masalah atau mempunyai soalan mengenai anda Amprobe SM-CAL1 Sound Meter Calibrator, please contact Amprobe customer support. Before contacting support, ensure you have reviewed the troubleshooting section of this manual. You can find contact information on the official Ampjubah webtapak atau melalui pengedar tempatan anda.

Dokumen Berkaitan - SM-CAL1

Praview Ampjubah AM-420 Digital Multimeter Manual Pengguna
Manual pengguna untuk Ampjubah AM-420 Digital Multimeter, memperincikan cirinya, keupayaan pengukuran, langkah berjaga-jaga keselamatan dan spesifikasi untuk ujian elektrik. Sesuai untuk kegunaan kediaman dan profesional.
Praview Ampjubah Manual Pengguna Kapasitans dan Rintangan CR50A
Manual pengguna ini menyediakan arahan komprehensif untuk mengendalikan Ampjubah CR50A Kapasitans dan Pengukur Rintangan, meliputi ciri, prosedur pengukuran, garis panduan keselamatan dan spesifikasi teknikalnya.
Praview Ampjubah AT-3500 Manual Pengguna Sistem Kabel/Paip Bawah Tanah
Manual pengguna yang komprehensif untuk Ampjubah Sistem Pencari Kabel/Paip Bawah Tanah AT-3500, memperincikan operasi, ciri, spesifikasi teknikal dan penyelenggaraan untuk pengesanan utiliti bawah tanah yang tepat.
Praview AmpManual Arahan Set Punggung Jubah TT-200 - Pengujian Talian dan Komunikasi
Manual arahan yang komprehensif untuk AmpSet Punggung Jubah TT-200, memperincikan ciri-cirinya untuk ujian talian, pengukuran rintangan penebat dan komunikasi sementara untuk juruteknik.
Praview Ampjubah IR-750 / IR-750-EUR 50:1 Manual Pengguna Termometer Inframerah
Manual pengguna untuk Ampjubah IR-750 dan IR-750-EUR 50:1 termometer inframerah. Ciri-ciri termasuk julat suhu yang luas, ketepatan tinggi, penuding laser, pengelogan data dan sambungan USB untuk aplikasi industri dan profesional.
Praview Ampjubah Panduan Mula Pantas Pencari Utiliti Bawah Tanah UAT-600
Panduan permulaan pantas untuk AmpJubah Siri Pencari Utiliti Bawah Tanah UAT-600, memberikan arahan mengenai lokasi aktif dan pasif utiliti menggunakan pelbagai mod seperti Kuasa, Radio, Induksi, Petunjuk Ujian Langsung dan Cl Isyaratamp.