Air King 9518

Air King 9518 18-Inch Industrial Grade Wall Mount Fan Instruction Manual

Model: 9518

pengenalan

This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of your Air King 9518 18-Inch Industrial Grade Wall Mount Fan. Please read all instructions carefully before use and retain this manual for future reference.

Depan view of the Air King 9518 18-Inch Industrial Grade Wall Mount Fan

Imej: Depan view of the Air King 9518 18-Inch Industrial Grade Wall Mount Fan, showcasing its black finish and robust metal grill.

Maklumat Keselamatan Penting

Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury to persons. This fan is designed for kegunaan dalaman sahaja in dry locations.

  • Jangan kendalikan mana-mana kipas dengan kord atau palam yang rosak.
  • Jangan letakkan tali pusat di bawah permaidani.
  • Do not immerse fan in water.
  • Unplug the fan from the outlet when not in use, before cleaning, or before servicing.
  • Do not allow children to operate this fan.
  • Ensure the mounting surface is structurally sound to support the fan's weight (approximately 24.8 pounds).
  • Produk ini mengandungi bahan kimia yang diketahui oleh Negeri California untuk menyebabkan kanser dan kecacatan kelahiran atau bahaya pembiakan lain.

Persediaan dan Pemasangan

The Air King 9518 fan is designed for wall mounting. Proper installation is crucial for safety and optimal performance. Refer to the official Manual Pemasangan (PDF) untuk arahan terperinci.

Komponen yang Disertakan:

  • Fan unit with motor and blades
  • Gril pelindung
  • Pendakap pemasangan dinding
  • Perkakasan pemasangan
  • Secondary safety cable
  • Manual Pengguna (dokumen ini)

Arahan Pemasangan:

  1. Select a suitable wall location that can securely support the fan's weight and allows for proper air circulation.
  2. Attach the wall mounting bracket to a sturdy surface, such as a wall stud, using appropriate fasteners (refer to installation manual for specifics).
  3. Securely attach the fan unit to the mounting bracket. Ensure all bolts are tightened.
  4. Install the secondary safety cable as an additional measure to prevent accidental detachment.
  5. Connect the 3-conductor power cord to a standard 120V AC outlet. The cord length is approximately 72 inches (6 feet).
Diagram showing fan dimensions and secondary safety cable

Image: Diagram illustrating the fan's dimensions (24"D x 16.5"W x 28"H) and the inclusion of a secondary safety cable for secure installation. The fan weighs approximately 24.8 lbs.

sebelah view of the Air King 9518 fan with its power cord

Imej: Sisi view of the Air King 9518 fan, showing its robust construction and the attached power cord.

Operasi

The Air King 9518 fan features a 1/6-horsepower motor with three speed settings, controlled by a rear-mounted pull cord switch.

Melaraskan Kelajuan Kipas:

  • Pull the chain once for the first speed setting (Low).
  • Pull the chain a second time for the second speed setting (Medium).
  • Pull the chain a third time for the third speed setting (High).
  • Tarik rantai itu buat kali keempat untuk mematikan kipas.

Directional Air Movement:

The fan head pivots up and down and can be turned side to side, allowing you to direct airflow precisely where needed. Loosen the adjustment knob on the mounting bracket, position the fan, and then tighten the knob to secure its position.

Close-up of the pull chain switch on the fan motor

Imej: A terperinci view of the rear-mounted pull chain switch, used to control the fan's speed settings and power.

Penyelenggaraan

Regular maintenance ensures the longevity and efficient operation of your fan.

  • Pembersihan: Sentiasa cabut plag kipas sebelum membersihkan. Gunakan pembersih lembutamp cloth to wipe down the exterior surfaces, including the grill and blades. Do not use abrasive cleaners or immerse the fan in water.
  • Motor: The 1/6-horsepower motor is fully enclosed and permanently lubricated, requiring no additional lubrication.
  • Storan: If storing the fan for an extended period, ensure it is clean and dry. Store in a cool, dry place.
Close-up of the fan grill and blades

Imej: Dari dekat view of the fan's protective grill and blades, highlighting areas that may require periodic cleaning.

Menyelesaikan masalah

If you experience issues with your Air King 9518 fan, consult the following common troubleshooting steps:

  • Kipas tidak dihidupkan:
    • Ensure the power cord is securely plugged into a functional 120V outlet.
    • Check the circuit breaker or fuse for the outlet.
    • Verify the pull chain switch is operated correctly through all speed settings.
  • Pengurangan aliran udara:
    • Check for any obstructions around the fan grill.
    • Clean any dust or debris from the fan blades and grill.
  • Bunyi atau getaran luar biasa:
    • Ensure the fan is securely mounted and all assembly hardware is tightened.
    • Check for any loose parts or foreign objects within the fan grill.
    • Verify the fan head is securely locked in its desired position.
Chart comparing fan noise levels to common sounds

Image: A chart illustrating the sound levels of the Air King 9518 fan at different speeds (High: 67 dB, Med: 58 dB, Low: 49 dB) compared to everyday sounds like traffic, dishwashers, and conversation.

Spesifikasi

Infographic showing fan power specifications: 1/6 HP, 120V, 1.5 AMPS

Image: Infographic detailing key electrical specifications of the fan: 1/6 Horsepower, 120 Volts, and 1.5 Amps.

CiriPerincian
Nombor Model9518
Rentang Bilah18 inci
Motor1/6 Horsepower, fully enclosed, permanently lubricated
Kelajuan Kipas3
Air Flow Capacity (High)7450 CFM
Air Flow Capacity (Medium)2970 CFM
Air Flow Capacity (Low)2660 CFM
Amperage (High)1.52 Amps
Amperage (Medium)1.3 Amps
Amperage (Low)1 Amp
Wattage (Tinggi)180 Watt
RPM (Tinggi)1500 RPM
RPM (Medium)1300 RPM
RPM (Rendah)1100 RPM
Tahap Bunyi (Tinggi)67 dBA
Noise Level (Medium)58 dBA
Tahap Bunyi (Rendah)49 dBA
bahanKeluli bersalut serbuk
Panjang Kord72 inci (6 kaki)
Voltage120 Volt
Berat Barang24.8 paun
Dimensi Produk (DxWxH)24"D x 16.5"W x 28"H
Penilaian ULLokasi Kering
PensijilanETL
PenggunaanDalaman

Maklumat Waranti

The Air King 9518 18-Inch Industrial Grade Wall Mount Fan comes with a Waranti Terhad Setahun. For specific terms and conditions, please refer to the warranty documentation included with your product or contact Air King customer support.

Customer Support and Additional Resources

For further assistance, detailed installation guides, or to contact customer support, please refer to the following resources:

Dokumen Berkaitan - 9518

Praview Air King 2EKZ7A/9046A Wall Mounted Oscillating Fan - Operating Manual & Safety Guide
Comprehensive operating manual and safety instructions for the Air King 16-inch wall-mounted oscillating fan (Model 2EKZ7A/9046A). Learn about installation, operation, maintenance, specifications, and limited warranty.
Praview Air King AK100L/AK100FL Exhaust Fan with Light - Installation and Operating Manual
This manual provides essential instructions for installing, operating, and maintaining the Air King AK100L and AK100FL exhaust fan with light. It includes safety precautions, troubleshooting tips, warranty information, and a parts diagram.
Praview AirKing 16-inch (40cm) Power Stand & Floor Fan User Manual
User manual for the AirKing 16-inch (40cm) Power Stand & Floor Fan with remote control, including important safety instructions, assembly, operation, and cleaning guidelines.
Praview AirKing 18" Pedestal Stand Fan (Model 4CH63D/9119D) - Operation, Assembly & Safety Manual
Comprehensive guide for the AirKing 18-inch Pedestal Stand Fan (Model 4CH63D/9119D), covering assembly, operation, safety precautions, maintenance, and limited warranty information.
Praview Air King Exhaust Fan Installation and Operation Manual
Comprehensive guide for installing, operating, and maintaining Air King exhaust fans, including safety information, troubleshooting, and warranty details for models AS50, AS60, AS70, and AS54.
Praview Manual Pemasangan dan Operasi Kipas Ekzos Air King AK100D/AK100DH
Panduan pemasangan, pengendalian, penyelesaian masalah dan jaminan yang komprehensif untuk kipas ekzos Air King AK100D dan AK100DH. Termasuk langkah berjaga-jaga keselamatan, gambar rajah pendawaian dan senarai bahagian.