Extech DO600

Extech DO600 Waterproof ExStik II Dissolved Oxygen Meter User Manual

Model: DO600

1. Pengenalan

The Extech DO600 Waterproof ExStik II Dissolved Oxygen Meter is designed for precise measurement of dissolved oxygen levels. It displays oxygen concentration as a percentage of saturation (0 to 200%) or as a concentration in parts per million (ppm) or milligrams per liter (mg/L) (0 to 20.00 ppm/mg/L). Key features include adjustable altitude compensation, adjustable salinity compensation, and an analog bargraph for trend indication. This manual provides instructions for the proper setup, operation, and maintenance of your DO600 meter.

2. Kandungan Pakej

Sahkan bahawa semua item ada dan dalam keadaan baik semasa membongkar:

Extech DO600 meter and included accessories

Figure 1: Extech DO600 meter with its accessories, including the electrode, caps, electrolyte, and neck strap.

3. Meter Components

Depan view of Extech DO600 Dissolved Oxygen Meter showing display and buttons

Rajah 2: Depan view of the Extech DO600 meter.

  1. Paparan LCD: Shows dissolved oxygen readings, temperature, and other indicators.
  2. MODE/HOLD Button: Toggles between measurement modes and holds the current reading.
  3. CAL/RECALL Button: Initiates calibration and recalls stored data.
  4. Butang HIDUP/MATI: Powers the meter on or off.
  5. Elektrod: Sensor for dissolved oxygen measurement.
  6. Protective Sensor Cap: Covers and protects the electrode.

4. Persediaan

4.1. Pemasangan Bateri

The DO600 meter uses four 3V CR-2032 batteries. These are typically pre-installed. If replacement is necessary:

  1. Twist off the battery compartment cap located at the top of the meter.
  2. Remove the old batteries, noting their polarity.
  3. Insert new CR-2032 batteries with the correct polarity.
  4. Securely replace the battery compartment cap to maintain the waterproof seal.

4.2. Electrode Preparation

Before first use or after prolonged storage, the DO electrode requires preparation:

  1. Unscrew the protective sensor cap from the electrode.
  2. Fill the spare membrane cap with the provided electrolyte solution. Ensure no air bubbles are trapped.
  3. Carefully screw the membrane cap onto the electrode, ensuring the membrane is taut and free of wrinkles.
  4. Allow the electrode to stabilize for approximately 15-30 minutes in the electrolyte solution before calibration.

5. Arahan Operasi

5.1. Hidupkan/Mati Kuasa

Tekan ke HIDUP/MATI button to power the meter on or off.

5.2. Penentukuran

Regular calibration ensures accurate readings. Calibrate the meter in air-saturated water or a known standard solution.

  1. Ensure the electrode is prepared as described in Section 4.2.
  2. Immerse the electrode in air-saturated water (e.g., tap water stirred vigorously for several minutes) or a DO standard solution.
  3. Tekan dan tahan butang CAL / RECALL butang sehingga "CAL" muncul pada paparan.
  4. The meter will automatically recognize the calibration point and adjust. Wait for the reading to stabilize and for the calibration indicator to confirm completion.

5.3. Mengambil Ukuran

To measure dissolved oxygen:

  1. Hidupkan meter.
  2. Immerse the electrode into the sample solution. Ensure the membrane is fully submerged and free of air bubbles.
  3. Gently stir the electrode in the sample to ensure proper flow across the membrane.
  4. Wait for the reading on the LCD display to stabilize. The display will show both dissolved oxygen and temperature.
  5. Tekan ke MODE / HOLD button to cycle between % saturation and ppm (mg/L) readings.
  6. To hold a reading, briefly press the MODE / HOLD button. Press again to release.
Scientist using Extech DO600 meter in a laboratory setting

Figure 3: The Extech DO600 meter being used to measure dissolved oxygen in a laboratory.

5.4. Altitude Compensation

Dissolved oxygen saturation levels are affected by altitude. The DO600 allows for manual adjustment:

5.5. Salinity Compensation

Salinity also influences dissolved oxygen levels. The DO600 provides adjustable salinity compensation:

6. Penyelenggaraan

6.1. Electrode Cleaning and Storage

To maintain electrode performance:

6.2. Penggantian Bateri

Gantikan bateri apabila penunjuk bateri lemah muncul pada paparan. Rujuk Bahagian 4.1 untuk arahan pemasangan bateri.

7. Penyelesaian masalah

MasalahKemungkinan PuncaPenyelesaian
Meter tidak dihidupkanBateri mati; Pemasangan bateri yang salahGantikan bateri; Periksa polariti bateri
Bacaan yang tidak tepat atau tidak stabilElectrode not calibrated; Fouled membrane; Air bubbles on membrane; Insufficient electrolytePerform calibration; Clean/replace membrane; Remove air bubbles; Refill electrolyte
No reading displayedElectrode not connected properly; Damaged electrodeEnsure electrode is securely attached; Replace electrode if damaged

8. Spesifikasi

ParameterNilai
ModelDO600
Dissolved Oxygen Range (Concentration)0 hingga 20.00 ppm (mg/L)
Dissolved Oxygen Range (Saturation)0 hingga 200.0%
Julat SuhuNot explicitly stated for display, but upper rating is 50 ℃
Pampasan Ketinggian0 to 20,000 feet (in 1,000 ft. increments)
Pampasan kemasinan0 hingga 50 ppt
Sumber KuasaFour 3V CR-2032 batteries
Dimensi6.9 x 1.6 x 1.4 inci (17.5 x 4.1 x 3.6 cm)
Berat Barang3.87 auns (0.11 kg)
Penilaian Kalis AirYes (implied by "Waterproof ExStik II")
Diagram showing the Extech DO600 meter with its dimensions: 7.7 inches (19 cm) in length.

Figure 4: Physical dimensions of the Extech DO600 meter. Note: The image shows 7.7 inches, while product specifications state 6.9 inches. Refer to the latest product documentation for precise measurements.

9. Video Produk

Tiada video produk rasmi daripada penjual ditemui untuk item ini dalam data yang diberikan.

10. Waranti dan Sokongan

For warranty information, technical support, or to purchase accessories and replacement parts, please refer to Extech's official weblaman web atau hubungi jabatan khidmat pelanggan mereka. Anda boleh mendapatkan maklumat lanjut di Kedai Extech di Amazon.

Dokumen Berkaitan - DO600

Praview Katalog Komprehensif Extech: Meter Alam Sekitar, Anemometer dan Peralatan Ujian
Terokai rangkaian luas meter persekitaran, termo-anemometer, pengesan gas, penguji kualiti air, meter bunyi, meter cahaya dan instrumen ujian dan pengukuran ketepatan lain Extech yang direka untuk aplikasi perindustrian, HVAC/R dan profesional.
Praview Manual Pengguna Meter pH Kalis Air Extech ExStik PH100 ​​& PH110
Manual pengguna yang komprehensif untuk Meter pH Kalis Air Extech ExStik, model PH100 ​​dan PH110. Memberikan arahan terperinci tentang operasi, penentukuran, penyelenggaraan elektrod, penggantian bateri, langkah berjaga-jaga keselamatan, spesifikasi dan penyelesaian masalah untuk peranti ujian pH berketepatan tinggi ini.
Praview Extech ExStik™ Waterproof pH Meters PH100 & PH110 User Guide
Comprehensive user guide for the Extech ExStik™ Waterproof pH Meters, models PH100 and PH110. Learn about operation, calibration, maintenance, and specifications.
Praview Extech ExStik II EC400 Conductivity, TDS, Salinity, Temperature Meter User Manual
Comprehensive user manual for the Extech ExStik II EC400 meter, detailing its features for measuring conductivity, total dissolved solids (TDS), salinity, and temperature. Includes setup, operation, calibration, maintenance, troubleshooting, and specifications.
Praview EXTECH 45170 Manual Pengguna Kelembapan, Suhu, Aliran Udara dan Meter Cahaya 4-dalam-1
Manual pengguna untuk EXTECH 45170, meter 4-dalam-1 mengukur kelembapan, suhu, aliran udara dan cahaya. Termasuk maklumat operasi, spesifikasi dan waranti.
Praview Manual Pengguna Meter pH Sawit Kalis Air Extech PH220
Manual pengguna untuk Meter pH Palm Kalis Air Extech PH220. Meliputi pengenalan, penerangan meter, operasi, penentukuran, pengukuran, penyimpanan, penggantian bateri, penyelenggaraan, penyelesaian masalah dan spesifikasi.