Intermatic EH10

Suis Masa Pemanas Air Elektrik Intermatic EH10 - Manual Pengguna

Jenama: Intermatic | model: EH10

Produk Selesaiview

The Intermatic EH10 Electric Water Heater Time Switch provides automatic control for electric water heaters. It offers precise programming and time-keeping capabilities, allowing for efficient management of hot water usage. This device supports various scheduling options, including daily, 5-day working week, weekend, or individual day scheduling, with up to 42 ON/OFF operations weekly. It features a convenient external override switch and an LED load indicator for user convenience.

Ciri-ciri Utama:

Persediaan dan Pemasangan

Installation of the Intermatic EH10 should be performed by a qualified electrician in accordance with all local and national electrical codes. The unit is designed for wall mounting and operates at 120 VAC at 50/60 Hz.

Internal Components and Wiring:

The image below displays the internal layout of the Intermatic EH10, showing the control panel, battery compartment, and wiring terminals. Proper connection to Neutral, Line 1, and Load 1 terminals is crucial for safe and effective operation. Always ensure power is disconnected before performing any wiring.

Dalaman view of Intermatic EH10 Electric Water Heater Time Switch with wiring diagram and control panel

Gambar 1: Dalaman view of the EH10 Time Switch, highlighting the control panel and wiring terminals.

Visualizing the Installation:

The Intermatic EH10 is typically installed on a wall near the electric water heater. Its compact design allows for discreet placement while providing easy access to controls.

Intermatic EH10 Electric Water Heater Time Switch installed on a wall next to a water heater

Gambar 2: Cthample installation of the EH10 Time Switch adjacent to an electric water heater.

Setup and Programming Video Guide:

For a comprehensive visual guide on setting up and programming your EH10 time switch, please refer to the official video below. This video covers initial setup, setting the current time, and programming schedules.

Video: How to Set up and Program the EH Series Water Heater Timer by Intermatic.

Arahan Operasi

The EH10 features an intuitive control panel for easy operation. The front panel includes a digital display, selector switches, and push buttons for setting time and programming events.

Depan view of Intermatic EH10 Electric Water Heater Time Switch control panel

Figure 3: Front control panel of the EH10 Time Switch.

Menetapkan Masa Semasa:

  1. Move the right selector switch to the MASA DITETAPKAN kedudukan.
  2. Tekan ke HARI button to advance to the current day.
  3. Tetapkan jam menggunakan JAM button, being mindful of AM/PM settings.
  4. Tetapkan minit menggunakan MIN button. You can hold the button down to advance more quickly.

Programming a Schedule:

  1. Move the right selector switch to the PROG position. The display will show "On" and "1", indicating you are setting the ON time for the first program.
  2. Tekan ke HARI button to select the day or combination of days for the ON event.
  3. Set the ON hour and minute using the JAM dan MIN butang.
  4. To set the OFF time for the first program, press the ON/OFF EVENT button. The display will show "Off" and "1".
  5. Tekan ke HARI button to select the day or combination of days for the OFF event.
  6. Set the OFF hour and minute using the JAM dan MIN butang.
  7. Repeat steps 2-6 for additional ON/OFF events (up to 42 per week).

Running the Programmed Schedule:

After programming, move the right selector switch to the LARI position. Ensure the left selector switch is in the AUTO position for automatic operation based on your set schedule.

Pembatalan Manual:

To temporarily override the programmed schedule, move the left selector switch to the LELAKI (Manual) position. You can then manually turn the timer ON or OFF using the ON/OFF EVENT button. To resume the programmed schedule, return the left selector switch to AUTO and the right selector switch to LARI, kemudian tekan butang ON/OFF EVENT butang sekali.

LED Load Indicator:

The red LED load indicator light on the control panel provides a visual cue of the water heater's status. When the light is on, the load is active (water heater is receiving power). This indicator is visible even when the enclosure door is closed.

Penyelenggaraan

Penggantian Bateri:

The EH10 time switch includes an "AA" alkaline battery for time-keeping and program information carryover during power outages. This battery typically protects data for a minimum of 3 years. If the display is blank or programming is lost after a power interruption, the battery may need replacement. Refer to the internal diagram for battery compartment location.

Pembersihan:

Periodically clean the exterior of the time switch with a soft, dry cloth. Do not use abrasive cleaners or solvents, as they may damage the unit's finish or internal components.

Menyelesaikan masalah

MasalahKemungkinan PuncaPenyelesaian
Timer display is blank or unit does not respond.No power supply or dead backup battery.Check power connection to the unit. Replace the "AA" alkaline backup battery.
Programmed schedule is not running.Selector switches are not in the correct position (RUN/AUTO).Ensure the right selector switch is in the LARI position and the left selector switch is in the AUTO kedudukan.
Water heater is not turning ON/OFF at programmed times.Incorrect programming or manual override is active.Review your programmed ON/OFF events. Ensure the left selector switch is in AUTO.
Unit gets warm or emits a slight odor.Normal operation for electrical components, or potential overload/fault.A slight warmth and new plastic smell can be normal initially. If excessive heat or a burning smell persists, disconnect power immediately and consult a qualified electrician.

Spesifikasi

Waranti dan Sokongan

Maklumat Waranti:

The Intermatic EH10 Electric Water Heater Time Switch comes with a Waranti 1 Tahun. This warranty covers replacement of the unit but does not include labor costs.

Sokongan Teknikal:

For any questions, assistance with setup, programming, or troubleshooting, please contact Intermatic Technical Support:

Dokumen Berkaitan - EH10

Praview Intermatic EH10/EH40 Electronic Water Heater Time Switch Manual
This manual provides installation, programming, and safety information for the Intermatic EH10 (120V) and EH40 (240V) electronic 7-day water heater time switches with battery carryover.
Praview Manual Pengguna Suis Masa Pemanas Air Elektronik 7 Hari Intermatic EH10 EH40
Manual arahan komprehensif untuk suis masa pemanas air elektronik 7 hari Intermatic EH10 dan EH40. Meliputi pemasangan, pengaturcaraan, spesifikasi, keselamatan dan maklumat jaminan.
Praview Suis Masa Intermatic ET2745: Panduan Pemasangan & Persediaan untuk Pemasa Elektronik 4-Litar 365/7-Hari
Arahan pemasangan dan persediaan terperinci untuk Suis Masa Elektronik 365/7 Hari Litar 4 siri Intermatic ET2745, meliputi konfigurasi, pengaturcaraan dan penyelesaian masalah untuk kawalan beban automatik.
Praview Intermatic WHQ Series 40A Water Heater Timers with Battery Backup - Installation and Operation Manual
Detailed information on the Intermatic WHQ Series 24-Hour/7-Day electromechanical water heater timers, including features, specifications, installation guide, programming instructions, and warranty information. Designed for residential, commercial, and industrial use.
Praview Intermatic Electronic Time Switches: ET70000C Series Specifier Guide
Comprehensive specifier guide for Intermatic's ET70000C Series Next Generation and First Generation Electronic Time Switches. Features, applications, technical specifications, and model comparisons for precise load control.
Praview Intermatic ET2705 Series Electronic 7-Day Time Switch Installation and Setup Guide
Comprehensive installation, setup, and programming guide for the Intermatic ET2705, ET2705CR, and ET2705CP Electronic 1-Circuit 7-Day Time Switches. Covers wiring, initial setup, scheduling, DST configuration, USB data transfer, and troubleshooting.