This manual provides instructions for the installation, operation, and maintenance of the EGB-02 Automatic Sliding Gate Motor Controller. This control board is designed specifically for sliding gate motors and rolling shutter motors, operating on either 110V or 220V AC power. It is not suitable for swing gate openers or other voltage requirements. Please read this manual thoroughly before installation and operation.
Spesifikasi
| Ciri | Spesifikasi |
|---|---|
| Model Produk | EGB-02 |
| Nama Jenama | LPSEKURITI |
| Input Kuasa | 110V atau 220V AC |
| Kekerapan | 433.92MHz |
| bahan | plastik |
| Fungsi | For rolling shutter motor and sliding gate opener |
| Kapasiti Memori | Up to 50 rolling code remote controls (HCS301, SN1646 compatible) |
| Mod Tanpa Wayar | TANYA |
| Pensijilan | CE |
| asal usul | Tanah Besar China |
| Board Dimensions (L x W x H) | 148 mm x 106 mm x 35 mm |
| Berat Pakej | 0.5 kg |
Persediaan dan Pemasangan
Langkah-langkah Keselamatan
- Pastikan bekalan elektrik diputuskan sebelum sebarang pemasangan atau pendawaian.
- Pemasangan hendaklah dilakukan oleh pegawai yang berkelayakan.
- Verify the power input matches your motor's voltage (110V or 220V AC).
- This board is NOT for swing gate openers.
Pengenalan Komponen
Refer to the image below for identification of the control board components and connection points.

Imej: Atas ke bawah view of the EGB-02 control board, showing connectors for Lamp, Motor, Power AC IN, Limit switches, Signal inputs, DIP switches, and the Learn button.
Arahan Pendawaian
Connect the necessary components to the terminal blocks as indicated on the board and in the diagram:
- Power AC IN: Connect the 110V or 220V AC power supply to the designated terminals. The board's transformer is rated for 220V AC primary and 12V AC secondary.
- Motor: Connect your sliding gate motor to the motor output terminals.
- Lamp: If applicable, connect an external warning lamp kepada lamp terminal.
- Had: Connect the gate's limit switches (Open and Close) to these terminals.
- Isyarat: This section includes terminals for various signal inputs such as:
- SEMUT: Antenna for remote control reception.
- Com: Titik persamaan.
- Ph: Photocell input for safety sensors.
- Vcc: Power output for accessories.
- Mulakan: Input for a single button or three-button switch.
- Buka tutup: Inputs for specific open/close commands.

Imej: Bersudut view of the EGB-02 control board, highlighting the terminal blocks for various connections.
Konfigurasi Suis DIP
The control board features a set of DIP switches (1-8) for configuring various operational parameters. The exact function of each switch may vary, but common settings include:
- Kawalan Arah: Switches may control the motor's opening/closing direction (e.g., 'Not-R Normal', 'Opposite' as indicated on the board).
- Mod Pengendalian: Configuration for features like auto-close, pedestrian mode, etc.
Consult the detailed wiring diagram or a specific manual for your gate motor system for precise DIP switch settings.
Berpasangan Alat Kawalan Jauh
The control board can learn up to 25 remote controls. To pair a remote control:
- Press the 'Learn' button on the control board. The 'Status' LED may illuminate or flash.
- Press a button on your remote control that you wish to use for gate operation.
- The 'Status' LED should indicate successful pairing (e.g., by flashing rapidly or turning off).
- Repeat for additional remote controls.
Nota: Only remote controls with HCS301 or SN1646 rolling code chips are compatible.
Operasi
Basic Gate Control
Use a paired remote control or a connected single/three-button switch to operate the gate:
- Press once to open the gate.
- Press again while opening to stop the gate.
- Press again while stopped to close the gate.
- Press again while closing to stop the gate.
Fungsi Boleh Laras
- Masa Bekerja: The maximum working time of the motor is adjustable, typically up to 60 seconds, to prevent continuous operation if an obstruction occurs. This can be set via a potentiometer on the board.
- Motor Output Torque: The motor's output torque can be adjusted to suit the gate's weight and movement requirements using the 'Open Overload Adjust' and 'Close Overload Adjust' potentiometers.
- Auto-Close Function: This feature allows the gate to automatically close after a set period once it has fully opened. This function can be enabled or disabled and its delay time adjusted via the control board settings (often using DIP switches or potentiometers).
- Midway/Pedestrian Mode: The adjustable midway/pedestrian mode allows the gate to open only a few feet, useful for pedestrian access without fully opening the main gate.
Ciri Keselamatan
The control board supports an infrared safety sensor interface. When connected, these sensors detect obstructions in the gate's path and can stop or reverse the gate's movement to prevent accidents.
Penyelenggaraan
- Keep the control board clean and free from dust and moisture.
- Periksa semua sambungan pendawaian secara berkala untuk kesesakan dan tanda-tanda haus atau kakisan.
- Ensure the area around the gate is clear of obstructions that could interfere with its operation.
- Test safety sensors regularly to ensure they are functioning correctly.
Menyelesaikan masalah
Isu dan Penyelesaian Biasa
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Pintu tidak bertindak balas terhadap alat kawalan jauh | Alat kawalan jauh tidak berpasangan; alat kawalan jauh tidak serasi; bateri alat kawalan jauh lemah. | Pair remote control; ensure remote uses HCS301/SN1646 rolling code; replace remote battery (12V, 27A). |
| Gate opens/closes partially or erratically | Limit switches misaligned or faulty; motor torque setting incorrect. | Adjust limit switches; adjust motor output torque using 'Overload Adjust' potentiometers. |
| Pintu berhenti tanpa diduga | Obstruction detected by safety sensor; motor overload; power interruption. | Check for obstructions; adjust motor overload setting; verify power supply. |
| Auto-close not working | Auto-close function disabled or delay set to maximum. | Enable auto-close via DIP switches/settings; adjust auto-close delay (max 60s). |
| Gate motor runs continuously | Limit switches not registering; working time setting too high. | Check limit switch connections and function; adjust maximum working time. |
Petua pengguna
- Always use a 12V, 27A battery for remote controls, not a 23A battery, to ensure proper function and longevity.
- Ensure your remote controls use HCS301 or SN1646 rolling code chips for compatibility with this control board.