1. Pengenalan
This manual provides comprehensive instructions for the installation, operation, and maintenance of the LILYTECH ZL-R200A Universal Air Source Heat Pump Water Heater Controller. The ZL-R200A is designed to efficiently manage air-to-water heating systems, offering a range of features for optimal performance and safety. Please read this manual thoroughly before installation and operation to ensure correct usage and to prevent damage.
2. Produk Lebihview
2.1. Komponen
The LILYTECH ZL-R200A controller kit typically includes the following components:
- Main Control Board (ZL-R200A-01A)
- Display Unit (ZL-R200A)
- Temperature Sensors (T1, T2)
- Pemasangan Pendawaian
- Connectors/Terminals



2.2. Ciri-ciri Utama
The ZL-R200A controller offers the following functionalities:
- Auxiliary Heating Function
- Water Flow Warning System
- Pump Control Ventilation
- Perlindungan antibeku
- Fungsi Penyahbekuan Automatik
- Automatic Restart Function (after power interruption)
- Temperature Depletion Management
- Compressor Delay and Pressure Protection
- Action Failure Sensor for enhanced safety
3. Spesifikasi
| Atribut | Nilai |
|---|---|
| Nombor Model | ZL-R200A |
| taip | Air Source Heat Pump Water Heater Controller |
| bahan | plastik |
| asal usul | Tanah Besar China |
| Panjang Pakej | 22 sm |
| Lebar Pakej | 18 sm |
| Ketinggian Pakej | 5 sm |
| Berat Pakej | 0.701 kg |
4. Persediaan dan Pemasangan
Important Safety Notice: Installation should only be performed by qualified personnel. Ensure all power is disconnected before beginning installation to prevent electric shock or damage to the unit.
4.1. Pemasangan Fizikal
- Mount the main control board in a secure, dry location, away from direct heat or moisture.
- Install the display unit in an easily accessible location for user interaction.
- Position temperature sensors (T1, T2) according to your heat pump system's requirements, typically for water temperature and ambient/coil temperature monitoring.
4.2. Gambarajah Pendawaian dan Sambungan
Refer to the main control board image below for connection points. Use the provided connectors and ensure secure connections for all wiring.

- Line-in (Power Supply): Connect the main power supply (AC ~) to the "Line-in" terminals. Ensure correct polarity (N for Neutral, L for Line).
- Pemampat: Connect the compressor unit to the designated "Compressor" terminals.
- HP (High Pressure Switch): Connect the high-pressure switch for safety monitoring.
- SM (Water Flow Switch): Connect the water flow switch to enable the water flowing warning function.
- HS (Hot Water Sensor): Connect the hot water temperature sensor (T1 or T2, depending on system design) to monitor water temperature.
- T1/T2 (Temperature Sensors): Connect the provided temperature sensors to their respective ports. These typically monitor water temperature and ambient/coil temperature for defrosting.
- Display Unit Connection: Connect the display unit to the main board using the provided cable.
Double-check all connections before applying power. Incorrect wiring can damage the unit or connected appliances.
5. Arahan Operasi
The ZL-R200A display unit features several buttons for control and monitoring:

- Butang Kuasa: Menghidupkan / mematikan unit.
- Anak panah atas/bawah: Adjust temperature settings, navigate menu options, or change parameter values.
- Butang M (Mod): Cycles through different operating modes (e.g., heating, auxiliary heating, defrost).
- S (Set) Button: Enters parameter setting mode or confirms selections.
5.1. Operasi Asas
- Hidupkan kuasa: Press the Power button to turn on the controller. The display will show the current water temperature.
- Tetapkan Suhu: Use the Up/Down arrows to adjust the desired water temperature. Press 'S' to confirm.
- Pilih Mod: Press the 'M' button to cycle through available operating modes. The display will indicate the active mode.
- Tetapan Parameter: Press and hold the 'S' button to enter the parameter setting menu. Use Up/Down arrows to navigate and adjust parameters, then 'S' to confirm and 'M' to exit. (Refer to advanced settings in a separate document for detailed parameter descriptions).
5.2. Fungsi Automatik
- Antibeku: The controller automatically activates heating elements or circulation pumps to prevent freezing when temperatures drop below a set threshold.
- Auto Nyahbeku: The system initiates a defrost cycle when ice buildup is detected on the outdoor coil, ensuring efficient operation.
- Mulakan Semula Automatik: Sekiranya berlaku kuasa outage, the controller will automatically resume its previous operating state once power is restored.
6. Penyelenggaraan
Regular maintenance ensures the longevity and optimal performance of your ZL-R200A controller.
- Pembersihan: Periodically wipe the display unit with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Sambungan: Annually inspect all wiring connections for tightness and signs of corrosion. Ensure all terminals are secure.
- Penderia: Check temperature sensors for physical damage or buildup that might affect accuracy. Clean if necessary.
- Pengudaraan: Ensure the main control board area has adequate ventilation and is free from dust or debris accumulation.
Untuk sebarang penyelenggaraan atau pembaikan dalaman, hubungi juruteknik yang berkelayakan.
7. Penyelesaian masalah
This section provides solutions to common issues you might encounter with your ZL-R200A controller.
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Pengawal tidak dihidupkan | No power supply; loose wiring; faulty unit. | Check power connections. Ensure main power is ON. Verify wiring to "Line-in" terminals. If problem persists, contact support. |
| Water flowing warning active | Insufficient water flow; faulty water flow switch (SM). | Check water circulation in the system. Ensure water pump is operating correctly. Inspect water flow switch for blockages or malfunction. |
| Heat pump not heating | Incorrect temperature setting; compressor issue; sensor failure; defrost cycle active. | Verify desired temperature setting. Check compressor connections. Ensure temperature sensors are correctly installed and functioning. Wait for defrost cycle to complete. |
| Paparan menunjukkan kod ralat | Action failure sensor triggered; specific system fault. | Note down the error code. Consult the detailed error code list (if available in a separate document) or contact technical support with the code. |
| Antifreeze function not working | Sensor malfunction; incorrect parameter setting. | Verify temperature sensor readings. Check antifreeze parameter settings in the menu. |
8. Petua Pengguna
Walaupun tiada semula pengguna tertentuviews or Q&A were provided, here are some general tips for optimizing your controller's performance:
- Peletakan Optimum: Ensure temperature sensors are placed in locations that accurately reflect the temperatures they are meant to measure (e.g., water tank, outdoor coil).
- Pemantauan Berkala: Periodically check the display for current status and any warnings to catch potential issues early.
- Pemasangan Profesional: For complex heat pump systems, consider professional installation to ensure correct wiring and optimal configuration.
9. Waranti dan Sokongan
For warranty information, technical support, or service inquiries, please refer to the contact details provided by your retailer or the manufacturer, LILYTECH. Keep your purchase receipt as proof of purchase.