1. Pengenalan
This manual provides essential information for the safe and effective installation, operation, and maintenance of your DONPER Refrigerator Inverter Board. This component is designed to regulate the power supply to the refrigerator's compressor, ensuring efficient and stable cooling performance. Please read this manual thoroughly before attempting any installation or repair.
2. Maklumat Keselamatan
CAUTION: Risk of electric shock. Before touching terminals, unplug the system from the power source and wait at least 30 seconds to allow capacitors to discharge. Failure to do so can result in serious injury or death.
- Always disconnect power to the refrigerator before servicing.
- Pastikan alat dibumikan dengan betul.
- Only qualified technicians should perform installation and repair.
- Do not operate the inverter board if it is damaged or wet.
- Keep the board dry and away from moisture.
3. Produk Lebihview
The DONPER Refrigerator Inverter Board is a critical electronic component responsible for controlling the speed of the refrigerator's compressor. This control optimizes energy consumption and maintains a consistent temperature within the appliance. The board features various connectors for power input, compressor output, and communication with other refrigerator components.



4. Spesifikasi
| Ciri | Spesifikasi |
|---|---|
| Jenama | DONPER |
| Nombor Model | 102-06-Y18-A 00-J-V73, 102-06-Y18-A 00-J-V74 |
| Input Voltage | 220-240V |
| Kekerapan | 50/60Hz |
| semasa | 1.4A |
| fasa | 1PH |
| Permohonan | Home Refrigerator |
| Pensijilan | CE, RoHS |
| Elektrik | No (refers to external power source, board itself is electric) |
| Bahan kimia yang sangat prihatin | tiada |


5. Pemasangan
This inverter board is a replacement part for specific refrigerator models. Installation should only be performed by individuals with appropriate technical knowledge and experience in appliance repair.
- Putuskan Kuasa: Ensure the refrigerator is completely unplugged from the main power supply. Wait at least 30 seconds for residual power to dissipate.
- Akses Papan Lama: Locate and carefully remove the access panel or cover that houses the existing inverter board in your refrigerator.
- Sambungan Dokumen: Before disconnecting any wires, take clear photos or make a diagram of all connections to the old board. Note the color and position of each wire.
- Putuskan Sambungan Papan Lama: Berhati-hati tanggalkan semua abah-abah pendawaian dan skru pelekap yang menahan papan penyongsang lama.
- Pasang Papan Baharu: Position the new DONPER inverter board in the same location as the old one. Secure it with the appropriate mounting screws.
- Sambung semula Pendawaian: Using your documented photos or diagrams, carefully reconnect all wiring harnesses to the new board. Ensure each connector is firmly seated. Refer to Figure 1 and Figure 3 for typical connector locations.
- Gantikan Sarung: Reinstall any access panels or covers removed earlier.
- Pulihkan Kuasa: Plug the refrigerator back into the power supply.
- Operasi Ujian: Monitor the refrigerator for proper operation, including compressor startup and cooling performance.
6. Operasi
The inverter board operates automatically once installed and power is supplied to the refrigerator. It continuously monitors the cooling demand and adjusts the compressor speed to maintain the desired temperature efficiently. There are no user-adjustable settings directly on the board itself.
7. Penyelenggaraan
The DONPER Refrigerator Inverter Board is designed for long-term, maintenance-free operation. However, to ensure its longevity and optimal performance:
- Keringkan: Ensure the area around the inverter board remains dry and free from moisture.
- Kebersihan: Periodically, with power disconnected, gently clean any dust accumulation on the board using a soft brush or compressed air.
- Pengudaraan: Ensure that the refrigerator's ventilation pathways are not obstructed, as proper airflow helps dissipate heat from electronic components.
8. Penyelesaian masalah
If your refrigerator experiences issues after installing the new inverter board, consider the following troubleshooting steps:
- No Power/No Cooling:
- Verify that the refrigerator is properly plugged into a working electrical outlet.
- Double-check all wiring connections to the inverter board, ensuring they are secure and correctly matched according to your documentation.
- Confirm that the main power supply to the refrigerator is active (e.g., circuit breaker is not tripped).
- Operasi sekejap:
- Ensure there is adequate ventilation around the refrigerator. Overheating can cause intermittent operation.
- Check for any loose connections that might be causing intermittent contact.
- Bunyi Luar Biasa:
- If new noises occur, ensure the inverter board is securely mounted and not vibrating against other components.
- Consult your refrigerator's main service manual for compressor-related noise diagnostics.
If problems persist, it is recommended to consult a professional appliance repair technician.
9. Petua Pengguna
- Pemeriksaan Keserasian: Sebelum pembelianasing, always verify the exact model number of your existing inverter board and compare it with the models listed for this product (102-06-Y18-A 00-J-V73, 102-06-Y18-A 00-J-V74). Some users have inquired about compatibility with specific brands like Philco side-by-side refrigerators; always confirm with your appliance's service manual or a qualified technician.
- Pemasangan Profesional: Due to the electrical nature and complexity of refrigerator components, professional installation is highly recommended to avoid damage to the appliance or personal injury.
10. Waranti dan Sokongan
For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt and product model numbers handy when contacting support.





