1. Pengenalan
The OONO MD-D1410-1 is a versatile 16Amp 48V 2x12 position screw terminal block distribution module designed for efficient power and signal distribution in various electronic and electrical applications. This module supports multiple extension connections, making it suitable for complex wiring setups. It features high-quality, UL CE CQC certified terminal blocks and a durable FR-4 glass fiber PCB, ensuring reliable performance.

2. Spesifikasi
Below are the detailed technical specifications for the OONO MD-D1410-1 terminal block distribution module:
| Ciri | Perincian |
|---|---|
| Nombor Model | MD-D1410-1 |
| Nilai Semasa | 16 Amp (total input or output) |
| Vol Maksimumtage | 48V |
| Terminal Block Type | Terminal Skru |
| Terminal Pitch (A/B blocks) | 7.5mm / 0.295" |
| Terminal Pitch (A1~B12 blocks) | 5.0mm / 0.197" |
| Julat Kawat | 26AWG ~ 12AWG / 2.5mm² |
| Panjang Jalur | 7mm |
| Skru | M3, steel, Cr3+ Zn plated |
| Pin Header and Cage | Tembaga |
| Bahan PCB | FR-4 glass fiber |
| Pensijilan | UL CE CQC certified terminal blocks |
| Penyesuaian | ya |
| asal usul | Tanah Besar China |
3. Kandungan Pakej
The package for the OONO MD-D1410-1 module typically includes:
- 1x OONO 16Amp 48V 2x12 Position Terminal Block Distribution Module
- Skru Pemasangan 2x
- 2x Pengangkut Angkasa Nilon

4. Pemasangan dan Pendawaian
The OONO terminal block module is designed for straightforward installation and wiring. Always ensure power is disconnected before making any connections.
4.1. Terminal Overview
- A / B Terminal Blocks: These are the main input/output terminals, typically used for connecting the primary power source or main signal lines. They have a pitch of 7.5mm.
- A1~B6 / A7~B12 Terminal Blocks: These are the distribution terminals, used for connecting individual loads or signal lines. They have a pitch of 5.0mm. The module supports 12 positions for each A and B line, totaling 24 distribution points.

4.2. Prosedur Pendawaian
- Sediakan Wayar: Strip approximately 7mm of insulation from the ends of your wires. Ensure the wire gauge is within the supported range (26AWG ~ 12AWG).
- Connect Main Lines: Connect your main power or signal lines to the A and B terminal blocks. These are located at the ends of the module.
- Connect Distribution Lines: Connect your individual loads or signal lines to the A1-B12 terminal blocks. Each A terminal (A1, A2, etc.) is connected to the main A line, and each B terminal (B1, B2, etc.) is connected to the main B line.
- Sambungan Selamat: Use a suitable screwdriver to tighten the M3 screws on each terminal block, ensuring a firm and secure connection. Do not overtighten.
- Pemasangan: Use the provided screws and nylon spacers to securely mount the module to a surface if required.
4.3. Gambarajah Sambungan
Refer to the following diagrams for typical connection methods and the internal schematic of the module.


5. Operasi
Once properly wired, the OONO terminal block module functions as a passive distribution point. It distributes the input voltage/signal from the main A and B terminals to the corresponding A1-B12 output terminals. Ensure that the total current drawn by all connected loads does not exceed the module's rated current of 16 Amp dan bahawa voltage remains within the 48V maximum.
6. Dimensi
The physical dimensions of the OONO MD-D1410-1 module are provided in the diagram below. All measurements are in millimeters (mm).

- Panjang Keseluruhan: Kira-kira 97.0 mm
- Lebar Keseluruhan: Kira-kira 22.0 mm
- Ketinggian Keseluruhan: Kira-kira 17.6 mm
- Diameter Lubang Pemasangan: 3.5 mm (2 PCS)
- Jenis Skru: M3
7. Petua Pengguna
Walaupun tiada petua pengguna khusus tersedia daripada pelangganviewatau Soal Jawab, berikut adalah beberapa cadangan umum untuk penggunaan optimum:
- Sahkan Sambungan: Before applying power, double-check all wiring connections to ensure they are secure and correctly aligned with the schematic.
- Pengimbangan Beban: When distributing power, try to balance the load across the available terminals to prevent overloading any single connection point or the module itself.
- Pertimbangan Alam Sekitar: Install the module in a dry, well-ventilated area, away from excessive heat, moisture, or corrosive substances.
- Pengurusan wayar: Use proper wire management techniques (e.g., cable ties) to keep wiring neat and prevent accidental disconnections or shorts.
8. Penyelesaian masalah
If you encounter issues with the terminal block module, consider the following basic troubleshooting steps:
- No Power/Signal:
- Check the main power source or signal input to the A/B terminals.
- Verify all wire connections are tight and correctly seated.
- Ensure the connected load is functioning correctly.
- Sambungan Terputus-putus:
- Inspect wires for damage or fraying.
- Re-tighten all terminal screws.
- Terlalu panas:
- Ensure the total current draw does not exceed 16 Amp.
- Check for any short circuits in the connected loads or wiring.
If problems persist, consult a qualified electrician or contact the manufacturer for support.
9. Penyelenggaraan
The OONO terminal block module requires minimal maintenance:
- Pemeriksaan Berkala: Periodically inspect the module and its connections for any signs of wear, corrosion, or loose wires.
- Pembersihan: If necessary, gently clean the module with a dry, soft cloth. Avoid using liquids or abrasive cleaners.
- Perlindungan Alam Sekitar: Ensure the operating environment remains within suitable conditions (dry, moderate temperature) to prolong the module's lifespan.
10. Waranti dan Sokongan
For information regarding warranty coverage, technical support, or service, please refer to the seller's policies or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.