1. Pengenalan
The KETOTEK KT3200 is a versatile digital temperature controller integrated into a socket timer. It displays the measured temperature and allows users to set start and stop temperatures to control heating or cooling equipment. This device also features a time function for independent day and night temperature control. It is widely applicable in intelligent control systems for heating, refrigeration, brewing, reptile habitats, aquaculture, greenhouses, and general home use.

2. Amaran Keselamatan
Please read these safety warnings carefully before operating the device.
- Sebelum menggunakan unit ini, periksa plastik casing for any damage. Do not use the device if it appears damaged.
- The relay has a maximum capacity of 16A. For resistive loads, use less than 14A. For inductive loads, use less than 2A.
- Jangan gunakan unit ini dalam persekitaran dengan gas meletup, stim berlebihan atau kepekatan habuk yang tinggi.
- Jangan benarkan kanak-kanak mengendalikan peranti.
- Jangan cuba membuka peranti sendiri.
3. Produk Lebihview dan Dimensi
3.1. Komponen Peranti

- Butang M: Tukar mod kerja
- + Butang: Tingkatkan nilai
- Butang OK: Select / C°/F° key (Press for 3s to switch C/F)
- - Butang: Kurangkan kunci
- Back / Reset Key: Tekan selama 3s untuk menetapkan semula
- Output Work Indicator: Light indicating output status.
3.2. Dimensi

- Lebar: 5.8 sm
- Ketinggian: 11.8 sm
- Kedalaman: 3.2 sm
- Dimensi Sensor: 2.4 cm (length) x 0.5 cm (diameter)
- Panjang Kabel Sensor: 290 cm (3 meter)
3.3. Available Plug Types

- Jenis AS

- Jenis EU

- Jenis FR

- AU Type

- Jenis UK

4. Mod Operasi
The KT3200 offers three distinct operating modes to suit various temperature control and timing needs.
4.1. M1 TC: Temperature Control Mode
In this mode, the device controls heating or cooling based on a set start and stop temperature.
- Tetapan: Define a 'start temperature' and a 'stop temperature'.
- Mod Pemanasan: Set the start temperature to be lower than the stop temperature. The device will activate the heating equipment when the measured temperature falls below the start temperature and deactivate it when it reaches the stop temperature.
- Mod Penyejukan: Set the start temperature to be higher than the stop temperature. The device will activate the cooling equipment when the measured temperature rises above the start temperature and deactivate it when it falls to the stop temperature.

4.2. M2 TC+Timer: Day/Night Temperature Control
This mode allows for different temperature control settings during daytime and nighttime periods within a 24-hour cycle.
- Tetapan: Set the current clock, Time 1 (start of day period), Time 2 (start of night period), TC 1 (temperature control settings for day), and TC 2 (temperature control settings for night).
- Operasi: During the daytime period (from Time 1 to Time 2), the device will operate according to the TC 1 program. During the nighttime period (from Time 2 to Time 1), it will switch to the TC 2 program.

4.3. M3 Timer: 2 Timer Period Timer Only
This mode functions purely as a timer, controlling the output based on two set time periods.
- Tetapan: Set the current clock, Time 1 (ON start time), and Time 2 (OFF start time).
- Operasi: The output will be ON during the period from Time 1 to Time 2. The output will be OFF during the period from Time 2 to Time 1.

5. Spesifikasi
| Ciri | Penerangan |
|---|---|
| Bekalan Kuasa | 100 ~ 250VAC 50 / 60Hz |
| Julat Kawalan Suhu | -40 ℃ ~ 120 ℃ / -72 ℉ ~ 176 ℉ |
| Unit Suhu | ℃/℉ Boleh Tukar |
| Menetapkan Masa | 0-24j / Pemasa kitaran harian |
| Ketepatan Kawalan | ±1℃ / ±1℉ |
| Jenis Sensor | NTC10K / B3950 |
| Output (Palam EU/UK/FR/AU) | Maksimum 16A / 230V |
| Output (Palam AS) | Maksimum 15A / 120V |
| Fungsi Khas | Reset function, Temperature calibration function, Memory function (except clock) when power off |
| Mod Kerja | M1 (Temperature Control), M2 (Temperature Control + Timer), M3 (Timer Only) |
| Panjang Kabel | 3M |
| Saiz Paparan | 1.9 Inci & Kebawah |
| Peranti Pintar | Tidak |
| Bateri Termasuk | Tidak |
| Pensijilan | CE |
6. Penyelenggaraan
To ensure the longevity and accurate performance of your KT3200 thermostat, follow these simple maintenance guidelines:
- Pembersihan: Gently wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these can damage the plastic casing dan komponen elektronik.
- Penjagaan Sensor: Keep the temperature sensor clean and free from debris. Ensure it is not exposed to extreme physical stress or sharp objects that could damage the cable or probe.
- Storan: Apabila tidak digunakan untuk tempoh yang lama, simpan peranti di tempat yang sejuk dan kering jauh dari cahaya matahari langsung dan suhu yang melampau.
7. Penyelesaian masalah
If you encounter issues with your KT3200 thermostat, consider the following troubleshooting steps:
- Peranti Tidak Dihidupkan: Ensure the device is securely plugged into a functional power outlet. Check the power supply voltage to ensure it is within the specified range (100~250VAC).
- Bacaan Suhu yang Salah: Verify that the temperature sensor is properly connected and positioned in the area where temperature needs to be measured. Ensure the sensor is not damaged. You may use the temperature calibration function if you suspect a consistent offset.
- Output Not Activating/Deactivating: Check your set start and stop temperatures or timer settings (Time 1, Time 2) to ensure they are configured correctly for your desired operation. Confirm that the connected appliance is working correctly.
- Peranti Tidak Responsif: Try performing a reset by pressing the 'Back / Reset' key for 3 seconds. This will revert settings to default, so reconfigure as needed.
- Isu Fungsi Memori: Remember that only the clock needs to be reset after a power failure if the device was in M2 or M3 mode. All other data is saved.
Jika masalah berterusan selepas mencuba langkah ini, sila hubungi sokongan pelanggan.
8. Petua Pengguna
- Kuasa Outage Pemulihan: The KT3200 features a memory function that saves all settings except the clock after a power failure. If operating in M2 (Temperature Control + Timer) or M3 (Timer Only) mode, remember to reset the clock upon power restoration. If in M1 (Temperature Control) mode, the device will automatically resume operation.
- Penukaran Unit Suhu: Easily switch between Celsius (℃) and Fahrenheit (℉) by pressing the 'OK' button for 3 seconds.
- Kepelbagaian Aplikasi: This thermostat is highly versatile and can be used for various applications such as controlling heaters in a room, maintaining optimal temperatures in incubators, regulating aquarium temperatures, or managing climate in greenhouses.
9. Waranti dan Sokongan
The KT3200 Timer Socket Thermostat comes with a 6-month warranty from the date of purchase.
For any inquiries or support needs, please contact our customer service. All emails will be answered within 1 business day. We are committed to providing assistance and resolving any issues you may encounter with your product.