MEXYBE A2

MEXYBE 4-in-1 TDS Meter Digital Water Tester User Manual

Model: A2

1. Produk Lebihview

The MEXYBE 4-in-1 Digital Water Tester is designed to accurately measure Total Dissolved Solids (TDS), Electrical Conductivity (EC), and temperature in both Celsius and Fahrenheit. This device features a high-precision chip and a premium titanium alloy probe for reliable results. It is suitable for testing drinking water, RO/DI systems, aquariums, hydroponics, pools, and more.

Ciri-ciri utama termasuk:

  • Fungsi 4-dalam-1: Measures TDS, EC, Temperature (°C, °F).
  • LCD Lampu Belakang Besar: 25% larger display for easy reading.
  • Fungsi Auto-Kunci: Simplifies usage by locking readings.
  • Factory Calibrated: Ready for direct use.
  • Fungsi Tahan: Freezes the reading on the display.
  • Automatik: Matikan kuasa selepas 2 minit tidak aktif untuk menjimatkan bateri.
  • TDS Chart: Convenient chart on the back of the tester and in the user guide for quick PPM value interpretation.
MEXYBE 4-in-1 TDS Meter showing 4 display modes: TDS, EC, Celsius, Fahrenheit.

Image 1.1: The MEXYBE 4-in-1 TDS Meter displaying its four measurement modes: TDS (ppm), EC (µs/cm), Celsius (°C), and Fahrenheit (°F). Note that the device does not measure pH or water hardness.

2. Persediaan dan Komponen

Before first use, ensure the batteries are correctly installed. The device comes with 2 LR44 batteries included and pre-installed.

2.1 Komponen

Diagram of MEXYBE 4-in-1 TDS Meter components including battery compartment, LCD, buttons, probe, and pen cup.

Image 2.1: Detailed diagram of the MEXYBE 4-in-1 TDS Meter, highlighting its key components: two replaceable batteries, energy-efficient chipset, large backlit LCD, MODE button, CLEAR button, ON/OFF HOLD button, immerse line, highly sensitive titanium alloy probe and sensor, and pen cup.

  1. Petak Bateri: Located at the top, holds two LR44 batteries.
  2. Paparan LCD dengan lampu latar: Menunjukkan bacaan ukuran.
  3. Butang MOD: Switches between TDS, EC, and Temperature (°C/°F) display modes.
  4. Butang CLEAR: Clears the current reading.
  5. ON/OFF HOLD Button: Powers the device on/off and activates the hold function.
  6. Immerse Line: Indicates the maximum immersion depth for the probe.
  7. Titanium Alloy Probe: High-precision sensor for accurate measurements.
  8. Pen Cup: Protective cover for the probe.

2.2 Pemasangan Bateri

The device comes with batteries pre-installed. To replace batteries:

  1. Gently slide open the battery compartment cover at the top of the device.
  2. Keluarkan bateri LR44 lama.
  3. Insert two new LR44 batteries, ensuring correct polarity.
  4. Tutup penutup petak bateri dengan selamat.

3. Arahan Operasi

Follow these steps for accurate water quality testing:

  1. Sediakan Sample: Pour the water to be tested into a clean container.
  2. Hidupkan kuasa: Tekan ke ON/OFF HOLD button to turn on the meter. The display will light up.
  3. Immerse the Probe: Remove the protective pen cup. Dip the probe into the water sample up to the immerse line. Do not immerse above this line.
  4. Hand immersing the TDS meter probe into a glass of water up to the immerse line.

    Image 3.1: Proper immersion of the TDS meter probe into a water sample. Ensure the water level does not exceed the indicated immerse line.

  5. Stir Gently: Gently stir the meter in the water to remove any air bubbles and ensure a stable reading.
  6. Hand gently stirring the TDS meter in a glass of water.

    Image 3.2: Gently stirring the meter in the water to ensure accurate and stable readings by removing air bubbles.

  7. Tunggu Bacaan: Allow a few seconds for the reading to stabilize. The auto-lock function will typically hold the stable reading.
  8. TDS meter displaying a stable reading after a short wait.

    Image 3.3: The TDS meter displaying a stable reading after the probe has been immersed and gently stirred in the water sample.

  9. Read the Value: Read the displayed value. If the reading is not locked, press the ON/OFF HOLD button to freeze the display.
  10. Hand pressing the ON/OFF HOLD button on the TDS meter to lock the reading.

    Image 3.4: Pressing the ON/OFF HOLD button to manually freeze the displayed reading for easier recording.

  11. Tukar Mod: Tekan ke MODE button to cycle through TDS (ppm), EC (µs/cm), Celsius (°C), and Fahrenheit (°F) measurements.
  12. Matikan: Tekan ke ON/OFF HOLD button again to turn off the meter. The device will automatically shut off after 2 minutes of inactivity.
  13. Bersihkan dan Simpan: Rinse the probe with clean water and replace the protective pen cup before storing.

3.1 Interpreting TDS Readings

A colorful TDS chart is provided on the back of the tester and in this guide for quick reference:

TDS chart showing water quality levels based on PPM values.

Image 3.5: TDS chart illustrating water quality based on PPM (parts per million) values. Ranges include Ideal drinking water (0-50 ppm), Comparatively ideal drinking water (50-100 ppm), High hardness water (100-200 ppm), Marginally Acceptable (200-300 ppm), Scale will form (300-400 ppm), The taste is not very pleasant (400-500 ppm), and U.S EPA's maximum contamination level (500+ ppm).

TDS Measurement Guidelines (PPM)
Julat PPM Kualiti Air
0-50 Ideal drinking water
50-100 Comparatively ideal drinking water
100-200 High hardness water
200-300 Boleh Diterima Secara Marginal
300-400 Scale will form
400-500 The taste is not very pleasant
>500 U.S EPA's maximum contamination level

4. Penyelenggaraan

Proper maintenance ensures the longevity and accuracy of your MEXYBE TDS Meter.

  • Membersihkan Probe: After each use, rinse the probe thoroughly with clean distilled water to prevent residue buildup. Do not use abrasive materials or harsh chemicals.
  • Storan: Always replace the protective pen cup after use. Store the meter in a cool, dry place away from direct sunlight and extreme temperatures.
  • Penggantian Bateri: Replace batteries when the display becomes dim or the meter fails to power on. Use only LR44 batteries.
  • Penentukuran: The meter is factory calibrated. If you suspect inaccurate readings over time, recalibration may be necessary. Refer to the manufacturer's website or contact support for detailed calibration instructions.

5. Penyelesaian masalah

If you encounter issues with your TDS meter, refer to the following common problems and solutions:

Masalah Kemungkinan Punca Penyelesaian
Meter tidak dihidupkan. Bateri mati atau tidak dipasang dengan betul. Check battery polarity or replace with new LR44 batteries.
Inaccurate or unstable readings.
  • Probe not clean.
  • Air bubbles on the probe.
  • Water temperature outside operating range.
  • Meter requires recalibration.
  • Rinse probe thoroughly with distilled water.
  • Gently stir the meter in the sample to remove bubbles.
  • Ensure water temperature is within 0-80°C (32-176°F).
  • Contact customer support for recalibration guidance.
Paparan redup. Kuasa bateri rendah. Replace batteries with new LR44 batteries.

6. Spesifikasi

Ciri Perincian
Nombor Model A2
Pengukuran TDS (Total Dissolved Solids), EC (Electrical Conductivity), Temperature (°C, °F)
Julat TDS 0-9999 ppm
Julat Suhu 0-80°C (32-176°F)
Ketepatan ±2%
Bateri 2 x LR44 (termasuk)
Mati secara automatik 2 minit
Berat Barang 1.76 auns
Dimensi Pakej 6.38 x 1.3 x 0.71 inci

7. Waranti dan Sokongan

MEXYBE is committed to providing high-quality products and excellent customer service. Your satisfaction is our priority.

  • Sokongan Pelanggan: For any questions, concerns, or technical assistance, please contact our dedicated customer support team. We offer rapid and efficient responses through live chat and email.
  • Maklum balas: We value our customers' feedback to continuously improve our products and services.

For further assistance, please refer to the contact information provided with your product packaging or visit the official MEXYBE webtapak.

© 2025 MEXYBE. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.