B0DY1B33W

Generic Laboratory Centrifuge Machine 3500 RPM (Model B0DY1B33W) - User Manual

For efficient separation of liquids and solids in laboratory settings.

1. Pengenalan

The Generic Laboratory Centrifuge Machine, Model B0DY1B33W, is a high-performance benchtop unit designed for the efficient separation of liquids and solids in various laboratory applications. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your centrifuge.

Ciri-ciri utama termasuk:

2. Maklumat Keselamatan

Please read and understand all safety instructions before operating the centrifuge. Failure to follow these guidelines may result in injury or damage to the equipment.

3. Produk Lebihview

Familiarize yourself with the components of your centrifuge.

Generic Laboratory Centrifuge Machine with speed controller

Rajah 1: Depan view of the Generic Laboratory Centrifuge Machine, showing the main unit and control panel.

Close-up of the centrifuge control panel with speed dial

Rajah 2: Detail of the control panel, featuring the speed dial (OFF, 1-5) and indicator light.

Komponen:

4. Persediaan

  1. Membongkar: Carefully remove the centrifuge from its packaging. Retain all packaging materials for future transport or storage.
  2. penempatan: Place the centrifuge on a sturdy, level, and vibration-free workbench or counter. Ensure there is adequate space around the unit for ventilation and safe operation. Avoid direct sunlight or heat sources.
  3. Sambungan Kuasa: Ensure the speed control knob is in the "OFF" position. Connect the provided power cord to the centrifuge's power inlet and then to a grounded electrical outlet. Verify that the voltage matches the centrifuge's requirements.
  4. Pemeriksaan Awal: Open the lid and inspect the rotor for any foreign objects or damage. Clean if necessary.

5. Arahan Operasi

  1. Sediakan Samples: Fill your 10-15 ml test tubes with the samples untuk disentrifugasi.
  2. Balance Tubes: It is critical to balance the tubes before placing them in the rotor. Tubes must be loaded symmetrically with equal weights. For example, if using 2 tubes, place them opposite each other. If using 4 tubes, place them at 90-degree intervals. If using an odd number of tubes, use a balance tube filled with water to match the weight of your sample tiub.
  3. Load Rotor: Open the centrifuge lid and carefully place the balanced tubes into the rotor slots. Ensure they are seated firmly.
  4. Tutup Tudung: Close the centrifuge lid securely. The unit will not operate if the lid is not properly latched.
  5. Tetapkan Kelajuan: Turn the speed control knob to the desired setting (1-5). Setting '1' is the lowest speed, and '5' is the maximum speed (3500 RPM). The indicator light will illuminate when the unit is powered on and operating.
  6. Start Centrifugation: The centrifuge will begin operation immediately upon selecting a speed. Monitor the unit for any unusual vibrations or noises. If detected, turn the knob to "OFF" immediately and check tube balance.
  7. Stop Centrifugation: To stop the centrifuge, turn the speed control knob to the "OFF" position. The rotor will gradually slow down and stop. Do not attempt to open the lid until the rotor has come to a complete stop.
  8. Keluarkan Samples: Once the rotor has stopped, open the lid and carefully remove your centrifuged samples.

6. Penyelenggaraan

Regular maintenance ensures the longevity and optimal performance of your centrifuge.

7. Penyelesaian masalah

Rujuk bahagian ini untuk isu biasa dan penyelesaiannya.

MasalahKemungkinan PuncaPenyelesaian
Centrifuge does not startPower cord not connected; Lid not closed properly; Speed knob not set.Check power connection; Ensure lid is securely latched; Turn speed knob to a setting other than "OFF".
Getaran atau bunyi yang berlebihanTubes are unbalanced; Centrifuge not on a level surface; Damaged rotor.Re-balance tubes (ensure equal weight and symmetrical placement); Move centrifuge to a level surface; Contact support if rotor is damaged.
Lid cannot be opened after operationRotor has not come to a complete stop.Wait for the rotor to stop completely. Do not force the lid open.
Unit stops unexpectedly during operationImbalance detected; Power interruption.Check tube balance and restart; Check power supply.

8. Spesifikasi

CiriPerincian
ModelB0DY1B33W
Kapasiti Tiub8 tubes (10-15 ml compatible)
Kelajuan Maksimum3500 RPM
Jenis MotorCopper Winding Motor
Bahan BadanABS
Dimensi Produk12 x 10 x 8 inci
Berat Barang4.4 paun
PengeluarSPANCARE_PHARMACEUTICALS

9. Apa yang ada di dalam Kotak

Documents - B0DY1B33W – B0DY1B33W

tiada dokumen berkaitan