ATO ATO-Y2-80M2-4
ATO 1 hp (0.75kW) 3 Phase AC Induction Motor User Manual
Model: ATO-Y2-80M2-4
1. Pengenalan
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your ATO 1 hp (0.75kW) 3 Phase AC Induction Motor. Please read this manual thoroughly before using the product and retain it for future reference.
The ATO 1 hp (0.75kW) 3 Phase AC Induction Motor is designed for various general-purpose machinery applications, including fans, pumps, compressors, machine tools, gearboxes, and transportation systems. It features high efficiency, robust construction, and reliable performance.
2. Produk Lebihview
2.1 Ciri-ciri Utama
- Kecekapan Tinggi: Operates at 1 hp (0.75kW) with 1390 rpm, optimizing energy consumption and operational efficiency.
- Pembinaan Tahan Lama: Features F insulation class and high-temperature resistant pure copper coils for safe and extended operation.
- Penyejukan yang cekap: Equipped with heat dissipation holes and a totally enclosed fan-cooled (TEFC) design to prevent overheating and prolong service life.
- Reka bentuk padat: Suitable for various applications without requiring excessive space.
- Operasi Bunyi Rendah: Designed to provide a quieter working environment.
- Pemasangan Mudah: High-quality base plate with pre-drilled holes simplifies mounting.
2.2 Komponen
The following diagram illustrates the main components of the ATO AC Induction Motor:

Figure 1: Motor Components Overview
This image displays the internal and external components of the motor, highlighting the rotor, junction box, heat dissipation system, copper coils, cold-rolled silicon sheet steel, and the fixed base for mounting.
- pemutar: The rotating part of the motor.
- Kotak Persimpangan: Enclosure for electrical connections.
- Sistem Pelesapan Haba: Components designed to manage and release heat generated during operation.
- Copper Coils: Essential for electromagnetic induction.
- Cold-rolled Silicon Sheet Steel: Used in the motor's core for magnetic properties.
- Tapak Tetap: Provides stable mounting for the motor.
3. Apa yang ada di dalam Kotak
Selepas membongkar, sila sahkan bahawa semua item yang disenaraikan di bawah ada dan tidak rosak:
- 1x ATO 3 Phase AC Induction Motor (Model: ATO-Y2-80M2-4)
If any components are missing or damaged, please contact your supplier immediately.
4. Spesifikasi
The following table details the technical specifications of the ATO 1 hp (0.75kW) 3 Phase AC Induction Motor:

Rajah 2: Spesifikasi Teknikal
This image presents a detailed table outlining the motor's basic, technical, and environmental parameters.
| kategori | Parameter | Nilai |
|---|---|---|
| Asas | Model | ATO-Y2-80M2-4 |
| Standard Reka bentuk | IEC | |
| Berat badan | 15kg | |
| Jenis Bingkai | 80M | |
| Melekap | Horizontal Foot Mounting (B3) | |
| Kaedah Pendawaian | Output≤4hp (3kW), Y connection Output≥5.5hp (4kW), Delta connection | |
| Parameter Teknikal | Darjah Perlindungan | IP54/IP55 |
| Kelas Penebat | Kelas F | |
| Menyejukkan | TEFC (compliance to IEC 411 code of IEC 60034-6) | |
| Keluaran Nominal | 1 hp or 0.75kW | |
| Nombor Tiang | 4-tiang | |
| Kelajuan Nominal | 1390 rpm | |
| Kekerapan | 50Hz | |
| Nominal Voltage | 380V (Y connection by default) / 220V (Change Y to Δ connection on your own) | |
| Nominal Current (full load) | 2.05A/3.55A | |
| Kecekapan | 73% | |
| Power Factor (cosφ) | 0.76 | |
| Nominal Torque (Tn) | 5.15Nm | |
| Performance Ratios | Locked Rotor Torque/Nominal Torque (IST/Tn) | 2.3 |
| Maximum Torque/Nominal Torque (Tmax/Tn) | 2.3 | |
| Locked Rotor Current/Nominal Current (IST/In) | 6.0 | |
| Persekitaran | Tahap Kebisingan | 58dB(A) |
| Suhu Ambien | -15°C~+40°C | |
| Ketinggian | Ketinggian | Kurang daripada 1000m dari aras laut |
4.1 Dimensi
Refer to the following diagram and table for the physical dimensions of the motor:

Figure 3: Motor Dimensions Diagram
This diagram illustrates the key mounting and overall dimensions of the motor, with labels for each measurement point.
| Jenis Bingkai | Mounting Dimensions (mm) | Dimensi Keseluruhan (mm) | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| A | A/2 | B | C | D | E | F | G | H | K | AB | AC | AD | HD | L | |
| 80M | 125 | 62.5 | 100 | 50 | 19 | 40 | 6 | 15.5 | 80 | 10 | 165 | 175 | 145 | 220 | 295 |
5. Persediaan dan Pemasangan
5.1 Langkah Keselamatan
- Ensure power is disconnected before any installation or maintenance.
- Pemasangan hendaklah dilakukan oleh kakitangan yang berkelayakan sahaja.
- Pakai peralatan perlindungan diri (PPE) yang sesuai.
- Sahkan bahawa bekalan voltage and frequency match the motor's specifications.
- Pastikan motor dibumikan dengan betul.
5.2 Pemasangan
The motor is designed for horizontal foot mounting (B3). Use the pre-drilled holes on the fixed base for secure installation. Ensure the mounting surface is stable, level, and capable of supporting the motor's weight (15kg) and operational forces.
Refer to the dimensions in Section 4.1 for precise mounting hole spacing.
5.3 Sambungan Elektrik
The motor requires a 3-phase power supply. The default connection for nominal output ≤4hp (3kW) is a Star (Y) connection for 380V. For 220V operation, you may need to change to a Delta (Δ) connection. Consult a qualified electrician for wiring.
Wiring must comply with local electrical codes and regulations.

Rajah 4: Rajah Pendawaian
This image provides standard wiring diagrams for three-phase squirrel-cage induction motors, including Star (Y), Delta (Δ), and Star-Delta (Y-Δ) connections, as well as configurations for two-speed motors.
- Star (Y) Connection: Typically used for higher voltage (e.g., 380V). Connect terminals W2, U2, V2 together, and connect L1, L2, L3 to U1, V1, W1 respectively.
- Delta (Δ) Connection: Typically used for lower voltage (e.g., 220V). Connect U1-W2, V1-U2, W1-V2, then connect L1, L2, L3 to these respective junctions.
- Pembumian: Always connect the motor's ground terminal to a reliable earth ground.
6. Arahan Operasi
6.1 Pemeriksaan Pra Operasi
- Confirm all electrical connections are secure and correct.
- Ensure the motor is properly mounted and aligned with the driven equipment.
- Check for any obstructions around the motor's cooling fan and ventilation holes.
- Verify that the ambient temperature is within the specified range (-15°C to +40°C).
6.2 Memulakan Motor
- Apply power to the motor circuit.
- Observe the motor for any unusual noises, vibrations, or overheating during the initial startup.
- If any abnormalities are detected, immediately shut off power and investigate the cause.
6.3 Menghentikan Motor
To stop the motor, simply disconnect the power supply to the motor circuit.
7. Penyelenggaraan
Regular maintenance is crucial for ensuring the longevity and optimal performance of your ATO AC Induction Motor. Always disconnect power before performing any maintenance.
7.1 Routine Checks (Monthly)
- Pemeriksaan Visual: Check for any signs of physical damage, corrosion, or loose connections.
- Kebersihan: Ensure the motor's cooling fins and ventilation openings are free from dust, dirt, and debris to maintain efficient heat dissipation.
- Bunyi dan Getaran: Listen for any unusual noises or feel for excessive vibrations during operation.
- Suhu: Monitor the motor's operating temperature. Excessive heat can indicate a problem.
7.2 Bearing Lubrication
This motor typically uses sealed bearings that are lubricated for life and do not require routine re-lubrication. If the motor exhibits unusual bearing noise, consult a qualified technician for inspection and potential bearing replacement.
7.3 Sambungan Elektrik
Periodically check all electrical connections in the junction box for tightness and signs of wear or corrosion. Tighten any loose connections.
8. Penyelesaian masalah
This section provides guidance for common issues. For problems not listed or if solutions do not resolve the issue, contact technical support.
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Motor tidak hidup | Tiada bekalan kuasa Pendawaian yang salah Perlindungan beban lampau tersandung Motor dirampas | Periksa punca kuasa dan pemutus litar Verify wiring against diagrams (Figure 4) Reset overload protection; check for mechanical issues Inspect for mechanical obstruction or bearing failure |
| Motor terlebih panas | Pengudaraan yang tidak mencukupi Lebihan beban vol. salahtage / kekerapan Kegagalan galas | Clear obstructions from cooling fins/fan Kurangkan beban pada motor Verify power supply matches specifications Inspect bearings; replace if necessary |
| Bunyi atau getaran yang berlebihan | Pemasangan longgar Misalignment with driven equipment Bearing haus Unbalanced rotor | Ketatkan bolt pemasangan Semak dan betulkan penjajaran Inspect and replace bearings Consult a specialist for rotor balancing |
| Motor runs slowly or with reduced power | Volum rendahtage Lebihan beban Partial winding fault | Semak bekalan voltage Kurangkan beban Consult a qualified electrician for motor testing |
9. Waranti dan Sokongan
For warranty information, please refer to the documentation provided at the time of purchase or contact your retailer. ATO offers technical support for its products.