Manual Arahan

1. Pengenalan

The REFCO GOBI II Universal Condensate Pump is designed for efficient and quiet removal of condensate from air conditioning, HVAC, and dehumidifier systems. Suitable for systems ranging from 6,000 BTU/h to 120,000 BTU/h, this pump features a digital water sensor, universal voltage compatibility, and individually configurable flow rates, making it a versatile solution for various applications. This manual provides essential information for safe installation, operation, maintenance, and troubleshooting of your GOBI II pump.

REFCO GOBI II Universal Condensate Pump, assembled view

Figure 1.1: Assembled view of the GOBI II Universal Condensate Pump.

2. Maklumat Keselamatan

Sila baca semua arahan keselamatan dengan teliti sebelum pemasangan dan operasi. Kegagalan mematuhi arahan ini boleh mengakibatkan renjatan elektrik, kebakaran atau kecederaan serius.

  • Always disconnect power to the air conditioning unit and the pump before performing any installation, maintenance, or troubleshooting.
  • Installation must be performed by a qualified technician in accordance with all local and national electrical and plumbing codes.
  • Ensure the pump is installed in a location where it is protected from direct water spray and extreme temperatures.
  • Do not operate the pump with damaged cables or if it has been dropped or damaged.
  • This pump is designed for condensate water only. Do not use it for other liquids.
  • Keep children and unauthorized persons away from the installation area.

3. Produk Lebihview

The GOBI II pump system consists of several key components designed for reliable condensate removal.

Diagram showing GOBI II pump components and included accessories

Figure 3.1: GOBI II kit components and labeled diagram.

3.1. Komponen Termasuk:

  • Kabel kuasa
  • Kabel penggera
  • Star tube and anti-siphon device
  • Skru (untuk pemasangan)
  • Sauh skru
  • Factory-installed alarm fuse
  • Pengikat kabel

3.2. Ciri-ciri Utama:

  • Universal application for various AC systems.
  • High pumping capacity: 11 GPH (gallons per hour).
  • High discharge head: up to 65.6 ft.
  • Extremely quiet operation: less than 19 dB noise level.
  • Reliable digital water sensor, eliminating traditional float problems.
  • Demand-oriented control for optimized pumping capacity.

4. Persediaan dan Pemasangan

The GOBI II pump is designed for direct mounting under the air conditioner unit. Follow these steps for proper installation:

  1. Pemasangan: Secure the pump's wall back plate (component 9 in Figure 3.1) to a stable surface directly beneath the air conditioning unit using the provided screws and screw anchors. Ensure it is level.
  2. Pump Body Installation: Slide the pump body (component 1 in Figure 3.1) onto the mounted back plate until it clicks securely into place.
  3. Condensate Inlet Connection: Connect the condensate drain line from the air conditioning unit to the pump's inlet. Ensure a tight, leak-free connection.
  4. Sambungan Talian Pelepasan: Connect the 1/4" discharge tube from the pump's outlet to your desired drain point. Install the provided anti-siphon device in the discharge line to prevent backflow and ensure proper pump operation. Ensure the discharge line rises vertically for at least 6 inches before running horizontally or downwards.
  5. Sambungan Elektrik: Connect the power cable to the pump and then to a suitable power supply (100-240 VAC, 50/60 Hz). Ensure all electrical connections are secure and comply with local electrical codes.
  6. Alarm Cable Connection (Optional but Recommended): Connect the alarm cable to the pump's alarm relay terminals and integrate it with your HVAC system's alarm circuit if desired. The alarm relay is interchangeable (NO or NC) and rated for 250VAC, 6.3A or 28VDC, 6.3A.
  7. Ujian: Once all connections are made, restore power to the system. Pour a small amount of water into the air conditioner's drain pan to verify the pump activates and discharges water correctly. Check for any leaks.

5. Arahan Operasi

The GOBI II condensate pump operates automatically based on the water level detected by its digital sensor. It will activate when condensate accumulates and shut off once the water is cleared.

5.1. Digital Sensor and Flow Control:

The integrated digital sensor (component 4 in Figure 3.1) precisely monitors the water level, ensuring the pump activates only when necessary. The pump's demand-oriented control adjusts the pumping capacity as needed, optimizing efficiency and minimizing noise.

5.2. Diagnostic LEDs:

The pump features a diagnostic LED (component 8 in Figure 3.1) to indicate its operational status.

Diagram showing diagnostic LEDs: green for normal operation, red for error

Figure 5.1: Diagnostic LED indicators.

  • LED hijau: Indicates normal operation. The pump is powered and functioning correctly.
  • LED Merah: Indicates an error or alarm condition. Refer to the Troubleshooting section for possible causes.

6. Penyelenggaraan

Regular maintenance ensures the longevity and optimal performance of your GOBI II pump.

  • Cek Bulanan: Visually inspect the pump, inlet, and discharge lines for any blockages, kinks, or leaks. Ensure the pump housing is clean.
  • Pembersihan Tahunan: Disconnect power to the pump and the AC unit. Carefully remove the pump body from the wall back plate. Clean the water tray (component 5 in Figure 3.1) and the digital sensor (component 4) to remove any sludge, mold, or debris. A soft brush and mild detergent can be used. Rinse thoroughly with clean water.
  • Penggantian Penapis: The pump includes a replaceable filter (component 3 in Figure 3.1). Check its condition during annual cleaning and replace if it appears clogged or damaged.
  • Pemasangan semula: After cleaning, reassemble all components, ensuring they are securely in place. Restore power and test the pump's operation.

7. Penyelesaian masalah

If you encounter issues with your GOBI II pump, refer to the following table for common problems and solutions. Always disconnect power before attempting any inspection or repair.

MasalahKemungkinan PuncaPenyelesaian
Pam tidak berjalanNo power; Clogged inlet/outlet; Faulty sensor; Motor issueCheck power supply; Clear blockages; Clean digital sensor; Contact support if issue persists.
Pam berjalan secara berterusanAnti-siphon device missing/incorrectly installed; Leak in discharge line; Sensor issueInstall/check anti-siphon device; Inspect discharge line for leaks; Clean sensor.
Limpahan airPump not running; Clogged lines; Pump capacity exceeded; Alarm not connectedSee "Pump does not run"; Clear blockages; Ensure system BTU/h is within pump's range; Connect alarm.
Red diagnostic LED is onError condition (e.g., high water alarm, pump fault)Check for blockages, ensure proper installation, and verify power. If the issue persists after checking, contact technical support.

8. Spesifikasi

Detailed technical specifications for the GOBI II Universal Condensate Pump.

ParameterNilai
Maks. Kadar aliran11 GPH (0.18 Gelen Seminit)
Maks. Ketua Pelepasan65.6 kaki
Maks. Angkat Sedutan10 kaki
Tahap Kebisingan<19 dB(A)
Jenis PamJenis diafragma
Diameter Tiub1/4 ″
Voltage100 - 240 VAC
Kekerapan50 / 60 Hz
Penggunaan Tenaga8 W
Kelas PerlindunganI
Geganti PenggeraInterchangeable NO or NC, rated 250VAC, 6.3A or 28VDC, 6.3A
Perlindungan IngressIP44
Panjang Kabel5 kaki
Julat Suhu Operasi41 - 104 °F (5 - 40 °C)
Julat Suhu Air41 - 104 °F (5 - 40 °C)
Julat Suhu Penyimpanan-4 - 122 °F (-20 - 50 °C)
Berat Barang2.59 paun
Dimensi Pakej13.66 x 12.8 x 2.6 inci

8.1. Capacity Curve:

The following graph illustrates the pump's capacity (flow rate) versus vertical lift/head pressure.

Graph showing GOBI II pump capacity in GPH and l/hr versus vertical lift/head pressure in feet and meters

Figure 8.1: GOBI II Capacity Curve.

9. Waranti

The manufacturer warranty for the GOBI II Universal Condensate Pump begins with the commissioning of the unit. Please refer to the warranty documentation included with your purchase for specific terms and conditions.

10. Sokongan

For technical assistance, spare parts, or further inquiries, please contact your REFCO product supplier or visit the official REFCO webtapak untuk maklumat hubungan sokongan.

Dokumen Berkaitan - 3004145

Praview Gobi II Condensate Pump Installation and Operation Manual
Comprehensive guide for the REFCO Gobi II condensate pump, covering installation, operation, maintenance, and troubleshooting for HVAC/R systems.
Praview REFCO GOBI II Condensate Pump: Quick Installation Guide
Official quick guide for the REFCO GOBI II condensate pump (model 3004145). Provides essential information on installation, operation, safety, and maintenance for efficient condensate removal in HVAC systems.
Praview REFCO Gobi II Condensate Pump Installation and Operation Manual
A comprehensive guide to the REFCO Gobi II condensate pump, detailing installation, operation, safety precautions, technical specifications, and troubleshooting. Features include configurable quiet mode, diagnostic LED, USB connectivity, and broad application range.
Praview REFCO Combi Universal Condensate Pump 3004146 Installation and Technical Manual
This document provides comprehensive installation, technical specifications, safety guidelines, and troubleshooting information for the REFCO Combi Universal Condensate Pump (Model 3004146).
Praview REFCO VAMP-F Condensate Pump Quick Guide
A concise guide to the installation, operation, and maintenance of the REFCO VAMP-F condensate pump, designed for efficient removal of condensate from HVAC systems. Includes technical specifications and safety instructions.
Praview REFCO VAMP-Manual Arahan Pam Kondensat X
This instruction manual provides detailed information on the REFCO VAMP-X condensate pump, covering its specifications, installation, operation, maintenance, safety guidelines, and troubleshooting. Available in English, German, French, Italian, and Spanish.