Litime L-HYBINV-48V3KW-S

LiTime 3500W Pure Sine Wave Solar Inverter Charger User Manual

Model: L-HYBINV-48V3KW-S | Brand: LiTime

1. Pengenalan

This manual provides detailed instructions for the installation, operation, and maintenance of your LiTime 3500W Pure Sine Wave Solar Inverter Charger. This all-in-one unit integrates an MPPT controller, inverter, and charger, designed for efficient off-grid power, home energy storage, and cabin use. It features a peak surge of up to 6000W and delivers pure sine wave output. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Kandungan Pakej

Upon unboxing, verify that all components listed below are present and undamaged. The inverter is securely packaged with foam padding to prevent damage during transit.

Video 2.1: LiTime 3500W Pure Sine Wave Solar Inverter Charger Unboxing and Overview. This video demonstrates the unboxing process and provides an initial look at the inverter unit and its included accessories.

  • LiTime 3500W Pure Sine Wave Solar Inverter Charger Unit
  • Panduan Mula Pantas
  • Manual Pengguna
  • Accessory Bag containing:
    • Copper Wire Connectors (8 pcs)
    • M6*25/64"[10mm] Battery Post Bolts (2 pcs)
    • M6 Battery Wire Lugs (2 pcs)
    • Terminal Panel Spare Screws (4 pcs)
    • MC4 Connectors (2 pairs)
    • Sauh Plastik
    • Self-tapping Screws (for Panel Mount) (2 pcs)
    • Slotted Screwdriver (1 pc)
    • Heat Shrink Tubing (for PV&AC) (8 pcs)
    • Heat Shrink Tubing (for Battery) (2 pcs)
Included accessories for LiTime 3500W Solar Inverter Charger

Figure 2.1: Additional Components. This image displays the various connectors, screws, and tools included in the accessory bag for installation.

3. Ciri-ciri Produk

  • All-in-One Space Saving Design: Integrates an MPPT controller, inverter, and charger into a single unit, optimizing installation space. Offers a peak surge of up to 6000W for efficient auto solar tracking and pure sine wave output.
  • Smart Energy Manager: Supports four charging modes (Solar Only, Utility Priority, Solar Priority, Hybrid) and multiple output modes (Inverter Priority, PV Priority, Utility Priority) for flexible energy use and cost savings.
  • Fungsi UPS: Built-in Uninterruptible Power Supply (UPS) function ensures continuous power by automatically switching to battery backup during outages. Compatible with 48V lead-acid, lithium, and user-defined battery types.
  • Reliable and Protective Design: Features intelligent cooling fans and comprehensive protection against short-circuit, over-temperature, and overload for stable and long-lasting performance.
  • Advanced Communication & Integration: Supports RS485 for monitoring battery status (undervoltage / overvoltage/overcurrent) and includes a built-in LCD display for real-time monitoring of battery, solar, and AC status.
LiTime 3500W Solar Inverter Charger with labeled components

Figure 3.1: Inverter Components. This image highlights key components such as the LCD Screen, LED Indicators, Operation Buttons, Air Inlet Vent, AC Input Breaker, and Terminal Panel.

Diagram showing various protection features of the LiTime inverter

Figure 3.2: All-round Protection. Illustrates the inverter's protection mechanisms including over-temperature, battery undervoltage, PV night anti-backcharging, overload, load output short circuit, and battery overvoltage perlindungan.

Diagram showing 3-in-1 functionality and dimensions of the LiTime inverter

Figure 3.3: 3-in-1 Solar Inverter Charger. This diagram shows the integrated Pure Sine Wave Inverter (3500W), Solar Charge Controller (Max. 80A), and Battery Charger (Max. 40A), along with the unit's dimensions.

4. Persediaan dan Pemasangan

Proper installation is crucial for the safe and efficient operation of your inverter. Ensure all connections are secure and follow local electrical codes.

4.1 Memasang Penyongsang

Mount the inverter on a non-flammable surface in a well-ventilated area. Use the provided mounting bracket and screws. Ensure sufficient clearance around the unit for airflow.

belakang view of LiTime 3500W Solar Inverter Charger with labeled connection points

Rajah 4.1: Sambungan Panel Belakang. This image labels the On/Off Switch, Ground Terminal, AC Input/Output Terminal Blocks, USB-B Port, RS485 Port, Dry Contact Ports, Cooling Fans, Battery Positive and Negative Terminals, and PV Input Terminals.

4.2 Sambungan Pendawaian

Before making any connections, ensure the inverter is turned OFF and all power sources (solar, battery, AC grid) are disconnected. Connect the battery, solar panels, and AC input/output according to the diagram below. Use appropriate cable sizes and circuit breakers as recommended in the specifications.

System diagram showing connections between solar panels, inverter, battery, AC grid, generator, and load

Figure 4.2: Typical System Wiring Diagram. This diagram illustrates how the inverter connects to solar panels, a battery system, AC grid, a generator, and household loads. Note that utility power and generator AC cannot be used simultaneously.

  • Sambungan Bateri: Connect the 48V battery bank to the designated battery terminals. Ensure correct polarity.
  • Input PV: Connect your solar panel array to the PV input terminals. Verify that the open-circuit voltage and maximum power of your solar array are within the inverter's specified limits.
  • Input AC: Connect the AC grid or a generator to the AC input terminal block.
  • Keluaran AC: Connect your household loads or distribution panel to the AC output terminal block.
  • Pembumian: Pastikan inverter dibumikan dengan betul untuk mengelakkan bahaya elektrik.

Warning: Avoid mismatched voltages to prevent system damage. The utility power and generator AC cannot be connected to AC input simultaneously.

5. Mod Operasi

The LiTime inverter offers flexible charging and output modes to optimize energy management.

5.1 Mod Pengecasan

  • Solar Sahaja: Mengutamakan kuasa solar untuk pengecasan.
  • Keutamaan Utiliti: Prioritizes AC utility power for charging.
  • Keutamaan Suria: Uses solar power first, then supplements with utility power if needed.
  • Hibrid: Combines solar and utility power for optimal charging.

5.2 Mod Output

  • Inverter Priority: Prioritizes battery power through the inverter.
  • Keutamaan PV: Mengutamakan kuasa solar untuk beban.
  • Keutamaan Utiliti: Prioritizes AC utility power for loads.
Diagram illustrating four charging modes and three output modes of the inverter

Figure 5.1: Comprehensive Energy Management Solution. This diagram visually explains the four charging modes and three output modes available for flexible energy use.

6. Spesifikasi

CiriNilai
Nama Model3500W 48V All-in-One Solar Inverter Charger
Wattage3500 watt
Sumber KuasaGrid/Solar/Battery Powered
Penggunaan yang DisyorkanHome, Off-grid Cabin
Dimensi Produk16.77 x 13.22 x 4.88 inci
Berat Barang23.1 paun
Nombor Model ItemL-HYBINV-48V3KW-S
Suhu Operasi-10°C hingga 55°C / 14°F hingga 131°F
Kelas PerlindunganIP20
Input AC Voltage Julat90-140VAC
Maks. Arus Input Pintasan40A
Kuasa Nilai Output AC3500W
Keluaran AC Voltage120VAC ± 5%
Maks. Kuasa Input PV4400W
Recommended Open-circuit Voltage60-115V
Max. Open-circuit Voltage145V
Maks. Input Arus50A
MPPT Output Max. Power4200W
Maks. Caj Arus80A
Battery Input Rated Voltage48VDC
Bateri Input Voltage Julat40-60VDC
Max. AC Charge Current40A
Jenis BateriLithium / Lead Acid / User

7. Penyelenggaraan

Regular maintenance ensures the longevity and optimal performance of your LiTime inverter.

  • Pengudaraan: Ensure the air inlet vents are clear of dust and debris to maintain proper cooling.
  • Persekitaran: Keep the inverter in a dry, well-ventilated area, away from direct sunlight and moisture.
  • Sambungan: Periksa semua sambungan pendawaian secara berkala untuk memastikan ia ketat dan terdapat tanda-tanda kakisan.
  • Pembersihan: Bersihkan bahagian luar inverter dengan kain kering dan lembut. Jangan gunakan pembersih cecair.
  • Pemeriksaan: Regularly inspect the unit for any visible damage or unusual operation.

Warning: Do not disassemble the inverter. Refer to qualified personnel for any internal repairs.

8. Penyelesaian masalah

If you encounter issues with your inverter, refer to the following basic troubleshooting steps. For complex problems, contact customer support.

  • Tiada Kuasa/Paparan: Check battery connections, main power switch, and any external circuit breakers.
  • Kod Ralat: The LCD display will show error codes for specific issues. Consult the full user manual for a complete list of codes and their remedies. For example, Error Code 58 typically indicates a low battery condition or an overvoltage alarm if battery settings are incorrect.
  • Tiada Output AC: Verify that the inverter is turned on, battery voltage is sufficient, and no overload or short-circuit conditions are present. Check AC output connections.
  • Tiada Pengecasan: Ensure solar panels are connected and receiving sunlight, or AC input is active. Check charging mode settings.
  • Perlindungan Lebihan: Jika inverter dimatikan disebabkan oleh beban lampau, kurangkan beban yang disambungkan dan mulakan semula unit.

9. Waranti dan Sokongan

LiTime is committed to providing reliable products and excellent customer service.

  • Waranti: The product comes with a comprehensive warranty. Please refer to the warranty card included in your package or visit the official LiTime website for details on coverage and duration (up to 5-Year Service is available).
  • Sokongan Pelanggan: For technical assistance, troubleshooting, or warranty claims, please contact LiTime customer support.

10. Aplikasi

The LiTime 3500W Solar Inverter Charger is versatile and suitable for various applications requiring reliable off-grid power.

  • Sistem Penyimpanan Tenaga Rumah
  • Off-grid Cabins and Remote Residences
  • RV and Marine Applications
  • Penyelesaian Kuasa Sandaran
  • Solar Power Systems
  • Garaj dan Bengkel
Collage of images showing the inverter used in a home, farm, solar system, and garage settings

Figure 10.1: Wide Application. This image demonstrates the diverse environments where the LiTime inverter can be effectively utilized, including residential homes, farms, dedicated solar systems, and garages.

© 2024 LiTime. All rights reserved.