1. Pengenalan
The SURRYN MDP-P906 is a compact and versatile 300W digital power module designed for various applications including R&D laboratories, teaching experiments, digital product maintenance, and general power supply testing. This module offers high efficiency and precise control over voltage dan keluaran semasa.
Ciri-ciri utama termasuk:
- Custom input current limiting and undervoltage perlindungan.
- Voltage drop compensation and strong mode functionality.
- Multiple protection functions: input overvoltage, undervoltage, reverse connection, overcurrent, backflow, and overtemperature.
- Support for USB firmware upgrades.
- 2.4G wireless communication for connection with an intelligent display and control module (optional).
- Built-in silent, intelligent temperature-controlled cooling fan for stable and efficient output.
- Jilid lebartage input (DC 4.2V-30V) and PD2.0 quick recharging protocol support.
- 95% high-efficiency programmable linear output, up to 300W.
- High-performance MCU chip supporting multi-machine series or parallel operation.

Rajah 1: Depan view of the SURRYN MDP-P906 Digital Power Module, showing the display and control buttons.
2. Arahan Persediaan
2.1 Membongkar dan Pemeriksaan
Carefully unpack the MDP-P906 module. Verify that all components listed in the packing list are present and undamaged. The standard package includes:
- 1 x Power Supply Module (MDP-P906)
- 2 x Kabel Output
If you have purchased the optional intelligent display and control module, ensure it is also present.
2.2 Sambungan Kuasa
The MDP-P906 supports two types of power input:
- Direct Current (DC) Input: Connect a DC power source within the range of 4.2V to 30V (maximum 14A) to the DC 5.5/2.5 interface.
- PD2.0 Quick Recharging Protocol: Use a compatible PD2.0 power adapter providing 20V (maximum 5A) for input.
Ensure the input power source meets the specified voltage and current requirements to prevent damage to the module.
2.3 Sambungan Output
Connect the provided output cables to the output terminals of the MDP-P906 module. Connect the other end of the cables to your load device. Observe correct polarity (positive to positive, negative to negative).
2.4 Connecting the Optional Display and Control Module
If you have the intelligent display and control module, it can be connected to the MDP-P906 via 2.4G wireless communication. Refer to the display module's specific instructions for pairing and connection procedures. This allows for enhanced monitoring and control capabilities.

Figure 2: The MDP-P906 module connected to an optional intelligent display and control module, showing advanced monitoring.
3. Arahan Operasi
3.1 Operasi Asas
Once powered on, the MDP-P906 will display its current status. Use the 'SET', 'MENU', and 'RUN/LOCK' buttons on the module to navigate through settings and control output parameters.
- Butang SET: Digunakan untuk memasuki mod tetapan parameter dan mengesahkan pilihan.
- Butang MENU: Used to navigate through different menu options and settings.
- RUN/LOCK Button: Used to enable/disable output and to lock/unlock the controls to prevent accidental changes.
3.2 Menetapkan Voltan Outputtage dan Semasa
To set the desired output voltage dan semasa:
- Press the 'SET' button to enter voltage/current adjustment mode.
- Use the navigation buttons (often combined with 'MENU' or rotary encoders on the display module) to adjust the voltage dan nilai semasa.
- Press 'SET' again to confirm the values.
- Press 'RUN' to enable the output with the newly set parameters.
The module offers a high setting resolution of 10mV and 2mA (or up to 1mV and 1mA with the display control module).
3.3 Fungsi Lanjutan
The MDP-P906 supports advanced configurations for complex power requirements:
- Positive & Negative Output: Configure for bipolar output.
- Series Boost: Connect multiple modules in series to achieve higher output voltages.
- Parallel Current Sharing: Connect multiple modules in parallel to increase total output current capacity.
Refer to the detailed instructions provided with the optional display module for specific steps on configuring these advanced modes.

Figure 3: Multiple MDP-P906 units can be configured for series boost or parallel current sharing to meet diverse power needs.
4. Penyelenggaraan
4.1 Penjagaan Am
To ensure the longevity and optimal performance of your MDP-P906 module:
- Keep the module in a clean, dry environment, away from excessive dust, moisture, and direct sunlight.
- Elakkan daripada mendedahkan modul kepada suhu yang melampau atau perubahan suhu yang mendadak.
- Do not block the ventilation openings. The built-in cooling fan requires clear airflow to dissipate heat effectively.
- Clean the exterior of the module with a soft, dry cloth. Do not use liquid cleaners or solvents.
4.2 Kemas Kini Perisian Tegar
The MDP-P906 supports USB firmware upgrades. Periodically check the manufacturer's website for available firmware updates to ensure your device has the latest features and performance enhancements. Follow the instructions provided with the firmware update package carefully.

Figure 4: The MDP-P906 features a built-in silent cooling fan for efficient heat dissipation, ensuring stable operation.
5. Penyelesaian masalah
If you encounter issues with your MDP-P906 module, refer to the following common troubleshooting steps:
- Tiada Kuasa/Paparan:
- Ensure the input power source is correctly connected and providing the specified voltage (DC 4.2V-30V or PD2.0 20V).
- Periksa semua sambungan kabel untuk kelonggaran atau kerosakan.
- Verify the power source itself is functioning correctly.
- Tiada Output:
- Ensure the output is enabled by pressing the 'RUN' button.
- Check if the controls are locked (indicated by 'LOCK' on the display); press 'RUN/LOCK' to unlock.
- Verify that the output cables are correctly connected to the load and the module.
- Check for any active protection functions (e.g., overcurrent, overtemperature) that might have shut down the output. Address the cause of the protection trigger.
- Incorrect Output Readings:
- Ensure the module is properly calibrated. If issues persist, consider a factory reset (refer to advanced settings in the menu).
- Verify the accuracy of your measurement tools.
- Terlalu panas:
- Ensure adequate ventilation around the module. Do not block air inlets or outlets.
- Reduce the load if operating continuously at maximum power in a high ambient temperature.
Jika langkah ini tidak menyelesaikan isu ini, sila hubungi sokongan pelanggan untuk mendapatkan bantuan lanjut.
6. Spesifikasi
| Parameter | Nilai |
|---|---|
| Model | MDP-P906 |
| bahan | Aloi Aluminium |
| Input Voltage (DC) | 4.2V - 30V (Max. 14A) |
| Input Voltage (PD2.0) | 20V (Max. 5A) |
| Keluaran Voltage | 0V - 30V |
| Arus Keluaran | 0A - 10A |
| Kuasa Keluaran | Max 300W |
| Kecekapan Penukaran | Purata 95% |
| Resolusi Output | 10mV, 2mA (1mV, 1mA with display module) |
| Ketepatan Output | 0.03%+5mV, 0.05%+2mA |
| Adjust Rate (Load) | <±0.01% |
| Adjust Rate (Line) | <±0.01% |
| Riak Riak | <250uVrms, 3mVpp, 2mArms |
| Transient Response Speed | <4uS |
| Berat Barang | 10.6 auns (lebih kurang 300g) |
| Dimensi Pakej | 1.18 x 0.79 x 0.39 inci (lebih kurang 30 x 20 x 10 mm) |
| Pengeluar | SURRYN |
7. Maklumat Waranti
Warranty terms and conditions for the SURRYN MDP-P906 Digital Power Module are provided by the manufacturer or the authorized seller at the time of purchase. Please refer to your purchase documentation or contact the seller directly for specific details regarding warranty coverage, duration, and claims procedures.
8. Sokongan Pelanggan
For technical assistance, troubleshooting beyond the scope of this manual, or inquiries regarding your SURRYN MDP-P906 Digital Power Module, please contact your point of purchase or the manufacturer's customer support channels. Have your product model number (MDP-P906) and purchase details ready when contacting support.