Rigol DS1102Z-E

RIGOL DS1102Z-E Digital Oscilloscope User Manual

Model: DS1102Z-E | Brand: Rigol

1. Pengenalan

Thank you for choosing the RIGOL DS1102Z-E Digital Oscilloscope. This manual provides essential information for the safe and efficient use of your device. Please read it thoroughly before operation and keep it for future reference.

The DS1102Z-E is a high-performance digital oscilloscope designed for various applications including research and development, education, maintenance, and industrial testing. It features a 100 MHz bandwidth, 1 GSa/s sample rate, and a 24 Mpts memory depth, enabling precise analysis of complex waveforms.

2. Produk Lebihview

The RIGOL DS1102Z-E is a versatile measurement instrument integrating a frequency counter and supporting protocol decoding for RS232/UART, I2C, and SPI. It also includes FFT analysis and automatic measurement functions to enhance testing efficiency.

RIGOL DS1102Z-E Digital Oscilloscope front view

Rajah 2.1: Depan view of the RIGOL DS1102Z-E Digital Oscilloscope.

2.1 Ciri-ciri Utama

  • 100 MHz Bandwidth, 1 GSa/s Sampkadar le: Captures signals with high precision.
  • 24 Mpts Memory Depth: Allows for extended signal capture and detailed waveform analysis.
  • Multi-function Measurement Device: Includes frequency counter, protocol decoding (RS232/UART, I2C, SPI), FFT analysis, and automatic measurement functions.
  • Waveform Recording and Playback: Records signal variations and replays them for fault identification.
  • Paparan Definisi Tinggi: 7-inch TFT screen with 256-level grayscale, offering a phosphor-like display effect for clear waveform details.
  • Remote Control & Secondary Development Support: Equipped with USB and LAN ports for PC remote control, compatible with SCPI commands, LabVIEW, Visual Basic, and Visual C++.

2.2 Apa yang ada di dalam Kotak

Contents of the RIGOL DS1102Z-E Oscilloscope box

Figure 2.2: Contents included with the DS1102Z-E Oscilloscope.

  • 1x Main Unit (DS1102Z-E Digital Oscilloscope)
  • 2x Passive Probes (150MHz)
  • 1x Power Cable (EU plug)
  • 1x USB A-B Cable
  • 1x Kad Waranti
  • 1x Calibration Certificate
  • 1x Declaration of Conformity

3. Persediaan

Follow these steps to set up your RIGOL DS1102Z-E oscilloscope:

  1. Membongkar: Carefully remove all components from the packaging. Inspect the device for any signs of damage.
  2. Sambungan Kuasa: Connect the provided power cable to the oscilloscope's power input and then to a suitable AC power outlet.
  3. Sambungan Probe: Connect the passive probes to the BNC input connectors (CH1, CH2) on the front panel. Ensure a secure connection.
  4. Pembumian: Always ensure the oscilloscope is properly grounded through the power cable.
  5. USB/LAN Connection (Optional): If you plan to use remote control or secondary development, connect the USB cable to a PC or the LAN cable to your network.
RIGOL DS1102Z-E Oscilloscope dimensions and ports

Gambar 3.1: Lebihview of the oscilloscope's physical dimensions and ports.

4. Arahan Operasi

This section covers the basic operation of your oscilloscope.

4.1 Menghidupkan/Mematikan

  • Hidupkan kuasa: Press the power button located on the front panel. The device will perform a self-test and display the main interface.
  • Matikan: Tekan dan tahan butang kuasa sehingga peranti dimatikan.

4.2 Paparan Bentuk Gelombang Asas

After powering on, connect a signal to one of the input channels (e.g., CH1). Adjust the vertical scale (Volts/Div) and horizontal scale (Time/Div) knobs to display the waveform clearly. Use the AUTO button for automatic setup of the waveform display.

Oscilloscope display showing a waveform

Gambar 4.1: Cthample of a waveform displayed on the oscilloscope screen.

4.3 Fungsi Lanjutan

  • Fungsi Pengukuran: Tekan ke MENGUKUR button to access automatic measurements like frequency, period, peak-to-peak voltage, dll.
  • Sistem Pencetus: Use the trigger controls to stabilize repetitive waveforms. Adjust the trigger level and mode (Edge, Pulse, Video, Slope, etc.) as needed.
  • Rakaman Bentuk Gelombang: The oscilloscope allows recording and replaying waveforms. Access this feature through the menu to capture transient events.
  • Protocol Decoding: For serial bus analysis (RS232/UART, I2C, SPI), configure the decoding settings via the menu.
  • FFT Analysis: Perform Fast Fourier Transform (FFT) to analyze the frequency components of your signal.
Oscilloscope display showing a complex waveform with measurements

Figure 4.2: Complex waveform analysis with measurement data.

Oscilloscope display showing multiple waveforms and grid lines

Figure 4.3: Multiple waveforms displayed simultaneously for comparison.

5. Penyelenggaraan

Penyelenggaraan yang betul memastikan jangka hayat dan ketepatan osiloskop anda.

  • Pembersihan: Gunakan kain lembut dan kering untuk membersihkan bahagian luar osiloskop. Untuk kotoran degil, sedikitamp cloth with mild detergent can be used. Avoid abrasive cleaners or solvents.
  • Penjagaan Skrin: Clean the display screen with a soft, lint-free cloth. Do not use excessive force or harsh chemicals.
  • Storan: When not in use, store the oscilloscope in a clean, dry environment, away from direct sunlight, extreme temperatures, and excessive dust.
  • Penjagaan Probe: Handle probes carefully. Avoid bending or stressing the probe tips. Store them properly to prevent damage.
  • Penentukuran: For optimal performance, periodic calibration by qualified personnel is recommended. Refer to the official RIGOL website for calibration services.

6. Penyelesaian masalah

Bahagian ini menyediakan penyelesaian kepada isu biasa yang mungkin anda hadapi.

Masalah Kemungkinan Punca Penyelesaian
Tiada kuasa apabila dihidupkan. Power cable not connected, power outlet faulty, or power button issue. Check power cable connection. Test the power outlet. Ensure the power button is fully pressed.
Tiada bentuk gelombang dipaparkan. No signal input, probe not connected correctly, vertical/horizontal scale incorrect, or trigger not set. Verify signal source. Check probe connections. Adjust Volts/Div and Time/Div. Press AUTO or adjust trigger settings.
Waveform is unstable. Incorrect trigger settings. Adjust trigger level, mode, and source to stabilize the waveform.
Alat kawalan jauh tidak berfungsi. USB/LAN cable issue, incorrect network settings, or software driver not installed. Check cable connections. Verify network configuration. Install necessary drivers and software (e.g., UltraScope).

If the problem persists, please contact RIGOL technical support.

7. Spesifikasi

Detailed technical specifications for the RIGOL DS1102Z-E Digital Oscilloscope.

Technical specifications table for RIGOL DS1102Z-E

Figure 7.1: Visual representation of key technical specifications.

Ciri Spesifikasi
JenamaRigol
ModelDS1102Z-E
Lebar jalur100 MHz
Saluran2 Channels + EXT
Sample kadar1 GSa/s
Kedalaman Memori24 Mpts
Kadar Penangkapan Bentuk Gelombang30,000 wfms/s
Resolusi menegak8 bit
Sensitiviti Minimum1 mV/div
Minimum Time Base2 ns/div
Sokongan PenyahkodanRS232/UART, I2C, SPI
Analisis FFTStandard
Paparan7-inch TFT (800x480)
KetersambunganUSB Host, USB Device, LAN
Sumber KuasaPenyesuai AC
warnaKelabu / putih
Berat Barang2.9 Kilogram
Dimensi (L x W x H)31.31 x 16.08 x 12.24 sentimeter
Piawaian yang MematuhiCE, RoHS
Nombor Bahagian PengilangDS1102Z-E
Negara AsalChina

8. Waranti dan Sokongan

RIGOL is committed to providing high-quality products and excellent customer service.

  • Waranti: The RIGOL DS1102Z-E Digital Oscilloscope comes with a Waranti 3 tahun dari tarikh pembelian. Waranti ini melindungi kecacatan pada bahan dan mutu kerja di bawah penggunaan biasa.
  • Sokongan Teknikal: RIGOL offers Sokongan teknikal 24/7 to assist you with any questions or issues you may encounter. Please refer to the official RIGOL webtapak untuk maklumat hubungan dan sumber sokongan.
  • Sumber Dalam Talian: Visit the official RIGOL website for product documentation, software updates (e.g., UltraScope), and additional support materials.
RIGOL Oscilloscope multilingual support information

Figure 8.1: RIGOL oscilloscopes support multiple languages for user convenience.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.