VEVOR 3"-550

VEVOR 3"-550 Deep Well Submersible Pump Instruction Manual

pengenalan

This manual provides essential information for the safe and efficient operation of your VEVOR 3"-550 Deep Well Submersible Pump. Please read these instructions thoroughly before installation and use, and retain them for future reference.

The VEVOR 3"-550 Deep Well Submersible Pump is designed for reliable water supply from deep wells, suitable for domestic, agricultural, and industrial applications. It features a robust stainless steel construction, a powerful 550W motor, and a high flow rate.

Arahan Keselamatan

AMARAN: Kegagalan mematuhi arahan keselamatan ini boleh mengakibatkan renjatan elektrik, kebakaran atau kecederaan serius.

  • Pastikan bekalan kuasa sepadan dengan voltan pamtage (230 V / 50 Hz).
  • Always disconnect the power supply before performing any maintenance or installation.
  • Do not operate the pump without water or at a low water level to prevent overheating and damage.
  • The pump must be fully submerged during operation.
  • Handle the pump with care. Use the provided rope for lowering and raising the pump.
  • Pastikan semua sambungan elektrik ditutup rapat dan dilindungi daripada air.
  • Perkakas ini tidak dimaksudkan untuk digunakan oleh orang (termasuk kanak-kanak) yang kurang keupayaan fizikal, deria atau mental, atau kurang pengalaman dan pengetahuan, melainkan mereka telah diberi pengawasan atau arahan mengenai penggunaan perkakas oleh orang yang bertanggungjawab untuk keselamatan mereka.

Produk Selesaiview

The VEVOR 3"-550 Deep Well Submersible Pump is constructed from durable stainless steel, designed for longevity and resistance to corrosion. It features a powerful copper motor with built-in overheat protection.

VEVOR 3-inch Deep Well Submersible Pump

Image: VEVOR 3-inch Deep Well Submersible Pump, showing its stainless steel body and integrated power cable.

Ciri-ciri Utama:

  • Pembinaan Keluli Tahan Karat: Enhanced durability and corrosion resistance (IP68 waterproof rating).
  • Powerful Copper Motor: 550W motor with high-precision rotor and built-in overheat protection.
  • Kadar Aliran Tinggi: Maximum flow of 2100 L/h (35 L/min).
  • High Head Lift: Maximum head lift of 108 meters (354 feet).
  • Multiple Filtration Mesh: Stainless steel filter mesh to prevent impurities, suitable for sand content less than 5%.
  • Reka bentuk padat: 3-inch diameter, suitable for well casings of 3 inches or larger.
  • Aksesori yang disertakan: 20m electric cord and 20m rope.
Stainless Steel Discharge and Connection of VEVOR Pump

Image: Close-up of the pump's stainless steel discharge and connection, highlighting its robust construction.

VEVOR Pump Copper Motor with Overheat Protection

Image: Diagram illustrating the internal copper motor with high-precision rotor and built-in overheat protection.

Persediaan dan Pemasangan

Proper installation is crucial for the pump's performance and longevity. Follow these steps carefully:

  1. Prepare the Well: Ensure the well casing is at least 3 inches in diameter and free from debris.
  2. Attach the Rope: Securely attach the provided 20m rope to the designated sling holes on the pump. This rope will be used to lower and retrieve the pump.
  3. Connect Discharge Pipe: Connect a suitable discharge pipe (1-inch NPT) to the pump's outlet. Ensure a watertight seal.
  4. Sambungan Elektrik: Connect the 20m electric cord to a compatible power source (230V/50Hz). Ensure all connections are waterproof and meet local electrical codes.
  5. Turunkan Pam: Carefully lower the pump into the well using the rope. Ensure the pump is fully submerged in water. jangan let the pump rest on the bottom of the well; keep it suspended a few feet above the bottom to avoid drawing sediment.
  6. Semakan Awal: Before powering on, double-check all connections and ensure the pump is correctly positioned.
Diagram showing correct and incorrect vertical pump installation

Image: Illustration demonstrating correct vertical installation where the pump is fully submerged, and a warning against operating without sufficient water.

Arahan Operasi

Once installed, operating the VEVOR Deep Well Submersible Pump is straightforward:

  1. Hidupkan kuasa: Connect the pump to the power supply. The pump will start operating automatically.
  2. Pantau Aliran Air: Observe the water flow from the discharge. Ensure it is consistent and clear.
  3. Operasi Berterusan: The pump is designed for continuous operation as long as it is fully submerged and the water level is adequate.
  4. Perlindungan Terlalu Panas: The built-in overheat protection will automatically shut down the pump if it becomes blocked or overheats. If this occurs, disconnect power, allow the pump to cool, and investigate the cause before restarting.
Diagram illustrating pump operation with flow rate and head lift

Image: Operational diagram showing the submersible pump drawing water from a well, indicating a maximum flow of 35 L/min and a maximum head of 108m.

Penyelenggaraan

Penyelenggaraan yang kerap memastikan prestasi optimum dan memanjangkan jangka hayat pam.

  • Filter Mesh Cleaning: Periodically inspect and clean the stainless steel filter mesh to prevent clogging from sediment. For newly drilled wells with excessive granular sediment, consider adding a layer of gauze at the inlet.
  • Close-up of the pump's multiple filtration mesh

    Imej: Jarak dekat view of the pump's multiple filtration mesh, designed to filter impurities. A tip suggests adding gauze for new wells.

  • Semak Kerosakan: Annually, or if performance degrades, retrieve the pump and inspect the casing, cable, and connections for any signs of wear, corrosion, or damage.
  • Storan: Jika menyimpan pam untuk tempoh yang lama, bersihkannya dengan teliti, toskan semua air, dan simpan di lokasi yang kering dan bebas fros.

Menyelesaikan masalah

Rujuk jadual berikut untuk isu biasa dan penyelesaiannya:

MasalahKemungkinan PuncaPenyelesaian
Pam tidak bermulaNo power; tripped circuit breaker; motor overheat protection activated; faulty wiring.Check power supply; reset breaker; allow pump to cool and check for blockages; inspect wiring.
Aliran air rendah atau tiadaLow water level in well; clogged filter mesh; air in the system; discharge pipe blockage; worn impeller.Check well water level; clean filter mesh; bleed air from system; clear pipe blockage; contact service for impeller replacement.
Pam berjalan tetapi tiada airPump not fully submerged; airlock; suction leak.Ensure pump is fully submerged; prime the pump if possible (though submersible pumps are self-priming, air pockets can occur); check for leaks in the discharge line.
Kitaran pam kerap hidup dan matiLow water level; pressure switch malfunction (if applicable); small leak in system.Check well water level; inspect pressure switch; check for leaks in plumbing.

Spesifikasi

Technical specifications for the VEVOR 3"-550 Deep Well Submersible Pump:

SpesifikasiNilai
Model3QGD1-60-0.55 (3"-550)
bahanKeluli Tahan Karat
kuasa550 W
Voltage230V / 50Hz
Maks. Kadar aliran2100 L/h (35 L/min)
Max. Head Lift108 m (354.3 kaki)
Sand ResistanceKurang daripada 5%
Pump Diameter7.6 cm (3 inci)
Saiz Pelepasan2.5 cm (1 inch) NPT
Electric Cord Length20 m
Included Rope Length20 m
Gred Kalis AirIP68
Suhu Operasi0°C - 40°C
VEVOR 3-inch Deep Well Submersible Pump Specifications Diagram

Image: Diagram showing key dimensions and performance curves of the VEVOR 3"-550 Deep Well Submersible Pump, including flow rate, head lift, power, and voltage.

Waranti dan Sokongan

The manufacturer's warranty information is not explicitly provided in the product details. For warranty claims or technical support, please contact VEVOR customer service directly or refer to the official VEVOR webtapak.

Pengeluar: VEVOR

Nombor Model: 3QGD1-60-0.55

UPC: 840281544639

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.