Y&H MPS-VIII-4.2KW-24V-M140A

Y&H 4.2KW On/Off-Grid Solar Hybrid Inverter User Manual

Model: MPS-VIII-4.2KW-24V-M140A

1. Pengenalan dan Lebihview

This manual provides essential information for the safe and efficient operation of your Y&H 4.2KW On/Off-Grid Solar Hybrid Inverter. This device integrates an inverter, solar charger, and battery charger to provide uninterruptible power support. It features a 24VDC input, pure sine wave AC220V output, and a built-in 140A MPPT solar charge controller.

The inverter supports a maximum PV array power of 6200W and a maximum PV open circuit voltage of 500Vdc. The PV array MPPT voltage range is 90-450Vdc. It includes a cold start function (46V) and automatic restart upon AC recovery.

Y&H 4.2KW On/Off-Grid Solar Hybrid Inverter

Imej 1.1: Depan view of the Y&H 4.2KW On/Off-Grid Solar Hybrid Inverter.

2. Arahan Keselamatan

Please read all instructions and warnings in this manual before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury. Keep this manual for future reference.

3. Ciri-ciri Produk

Y&H 4.2KW Solar Inverter dimensions and features

Image 3.1: Key features and dimensions of the 4.2KW Solar Inverter, highlighting 140A MPPT, 6200W max PV power, 500VDC max PV open circuit voltage, pure sine wave, 50/60Hz auto, RGB lights, and one-click restoration.

Y&H Inverter RGB light indicators

Image 3.2: RGB light indicators on the inverter, showing purple for PV mode, red for battery mode, and blue for utility mode.

4. Persediaan dan Pemasangan

4.1 Sistem Selesaiview

The hybrid power system integrates solar power, a generator or utility grid, and a battery to supply power to home appliances. The inverter manages the power flow between these sources.

Gambarajah Sistem Kuasa Hibrid

Image 4.1: Diagram illustrating the hybrid power system, showing connections from solar panels, generator/utility, and battery to the inverter, which then powers home appliances.

4.2 Sambungan Bateri

The inverter is compatible with AGM, GEL, Flooded Lead-Acid, and Lithium batteries. For Lithium batteries, settings may need to be configured via the "User-Defined" option. Always use a circuit breaker between the battery and the inverter.

Inverter battery compatibility and cable size

Image 4.2: Inverter compatibility with various battery types (AGM, GEL, Flooded, Lithium, User-defined) and recommended battery cable size table.

Recommended Battery Cable Size:

ModelSaiz WayarKabel (mm²)Nilai tork (maks)
3.6KW/4.2KW/6.2KW1 x 2AWG252 Nm

4.3 AC Output Considerations

This inverter provides a single-phase 230V AC output. It does not provide 110V AC output directly. For 110V/120V US home appliances, a step-down converter (not included) is required to convert the 220V/240V AC power to 110V/120V AC power.

5. Arahan Operasi

5.1 Mod Pengecasan

The inverter supports four charging modes:

5.2 Mod Output

The inverter offers three output priority modes:

Four Safe Charging Modes and Three Output Modes

Image 5.1: Visual representation of the four charging modes (Solar Charging, Utility Charge, Solar Priority, Solar+Utility Charging) and three output priority modes (PV Priority, Utility Priority, SBU Priority).

5.3 WIFI Communication (Optional)

An optional WIFI module allows monitoring the inverter's working status and adjusting parameters remotely via a mobile phone application. The WIFI module is not included in the standard package.

WIFI Communication Function

Image 5.2: Illustration of the optional WIFI communication function, showing remote monitoring and parameter changes via a mobile app. Note: WIFI module is not included.

For more details on the WIFI module and its setup, please refer to the specific instructions provided with the module or visit the manufacturer's webtapak: Y&H Store

6. Penyelenggaraan

Penyelenggaraan tetap memastikan jangka hayat dan prestasi optimum penyongsang anda. Sentiasa putuskan sambungan semua punca kuasa sebelum melakukan sebarang penyelenggaraan.

7. Penyelesaian masalah

Bahagian ini menangani isu-isu biasa dan potensi penyelesaiannya.

Inverter setting 37 for hybrid operation

Image 7.1: Display showing setting 37 configured for "Hybrid" operation, where the inverter operates in hybrid mode, prioritizing solar energy for loads and charging, with excess energy feeding to the grid.

8. Spesifikasi

Below are the detailed technical specifications for the Y&H 4.2KW On/Off-Grid Solar Hybrid Inverter (Model: MPS-VIII-4.2KW-24V-M140A).

Product Data Sheet for Y&H Inverter

Image 8.1: Product Data Sheet providing comprehensive specifications for the MPS-VIII 3.6KW, 4.2KW, and 6.2KW models.

SpesifikasiNilai
JenamaY&H
Nombor ModelMPS-VIII-4.2KW-24V-M140A
Output Power Rated4200W
Maks. Kuasa Array PV6200W
Maks. Litar Terbuka PV Voltage500Vdc
PV Array MPPT Voltage Julat90~450Vdc
Maks. Mengecas Semasa140A
Input Voltage24 Volt DC
Keluaran Voltage220V/230V/240VAC (Single-phase)
bentuk gelombangGelombang Sinus Tulen
Suhu Operasi-10°C hingga 50°C
Kelembapan5%~95% (Relative Humidity, Non-condensing)
Pelabuhan KomunikasiRS232/WIFI (Optional)

9. Waranti dan Sokongan

The Y&H 4.2KW On/Off-Grid Solar Hybrid Inverter comes with a Waranti 12 bulan dari tarikh pembelian. Waranti ini melindungi kecacatan pada bahan dan mutu kerja di bawah penggunaan biasa.

For technical support, warranty claims, or further inquiries, please contact Y&H customer service through the retailer where the product was purchased or visit the official Y&H brand store online: Y&H Store on Amazon.