GOLDCHAMP GC-EU-38A

GOLDCHAMP GC-EU-38A Voltage dan Penguji Kesinambungan

Model: GC-EU-38A | Brand: GOLDCHAMP

1. Pengenalan

GOLDCHAMP GC-EU-38A is a digital voltage and continuity tester designed for testing AC/DC currents. It features a rotating field test, single-pole voltage test, and continuity test. For operation in low-light conditions, a built-in flashlight illuminates the measurement point. This voltmeter is suitable for use in electrical engineering, industrial applications, maintenance, and photovoltaics. Constructed with high-quality components, it provides accurate readings even after frequent use. Its compact dimensions and low net weight make it portable and easy to carry.

2. Langkah-langkah Keselamatan

Read all safety information and operating instructions before using this instrument. Failure to follow these warnings and instructions can result in electric shock, fire, or serious injury.

  • Never take measurements on a circuit where the electrical potential exceeds 690V. If the measured voltage exceeds 690V, all voltage LED indicators will illuminate.
  • Do not attempt to take measurements in the presence of flammable gases, as the instrument may cause sparks that could lead to an explosion.
  • Never use the instrument with wet hands or in the rain.
  • Simpan tangan dan jari anda di belakang penghalang semasa pengukuran.
  • Never unlock or open the battery compartment during measurement.
  • Always verify proper operation on a known live source before taking measurements.
  • Never attempt to take measurements under abnormal conditions, such as a broken casing or exposed metal parts on the instrument or test leads.
  • Jangan ubah suai instrumen.
  • Exercise extreme caution when the LED circuit flashes or illuminates.
  • The correct display of LEDs is guaranteed only within a temperature range of -10°C to 55°C (< 85% RH).

3. Ciri-ciri Produk

  • Bipolar Voltage Penguji: Ukuran AC/DC voltage (including three-phase AC power), displays three-phase AC power phase, ON/OFF test, continuity, phase rotation test, polarity detection, and self-inspection.
  • Pematuhan Keselamatan: Features a low battery indicator and over-range voltage indicator. Complies with safety requirements for double insulation, CAT III 690V, CAT IV 600V, and CE standards.
  • Mudah Digunakan: Backlit digital LCD for clear readings. Portable design.
  • Julat Pengukuran: 12-690V AC/DC. Accuracy (23 ± 5°C): (3% + 3) or 5V. Range/Resolution: 7-690V/1V (Auto-range).
  • Lampu suluh bersepadu: Untuk menerangi kawasan kerja yang gelap.
  • Fungsi Pegangan Data: Locks the measured value on the LCD for convenient reading.
  • Matikan Automatik: Saves battery life when not in use.
  • Kelas Perlindungan IP64: Protected against splashes and dust.
GOLDCHAMP GC-EU-38A Voltage Tester with key features listed

Figure 3.1: Key features of the GOLDCHAMP GC-EU-38A Voltage Tester, including pen light, auto power off, continuity test, LED indication, threshold voltage, and phase rotation test.

4. Bermula

4.1 Membongkar

Carefully remove the GOLDCHAMP GC-EU-38A Voltage and Continuity Tester from its packaging. Ensure all components are present:

  • 1 x Jldtage Tester with Test Probes
  • 1 x Manual Pengguna
  • 2 x 1.5V Batteries (AA type)

4.2 Pemasangan Bateri

The tester is powered by two 1.5V batteries (IEC LR03 1.5Vx2). To install or replace batteries:

  1. Pastikan peranti dimatikan dan diputuskan sambungan daripada mana-mana sumber kuasa.
  2. Locate the battery compartment cover, typically at the bottom or rear of the device.
  3. Use a small coin to open the battery compartment cover.
  4. Insert the two 1.5V batteries, observing the correct polarity (+/-) as indicated inside the compartment.
  5. Tutup penutup petak bateri dengan selamat.
GOLDCHAMP GC-EU-38A Voltage Tester showing battery compartment and dimensions

Figure 4.1: The GOLDCHAMP GC-EU-38A Voltage Tester with its battery compartment open, showing the required 1.5V AA batteries.

4.3 Initial Self-Test

Before each use, it is recommended to perform a self-test on a known live source to ensure the tester is functioning correctly. If the power indicator light blinks or goes out during the self-diagnostic test, the battery may need to be replaced.

Image showing how to replace batteries and use the probe clip on the GOLDCHAMP GC-EU-38A

Figure 4.2: Illustration of battery replacement and the convenient probe clip feature.

5. Arahan Operasi

5.1 Berakhirview Komponen

Labeled diagram of the GOLDCHAMP GC-EU-38A VoltagKomponen Penguji e

Figure 5.1: Labeled diagram showing the lamp light, LCD display, SELECT key, battery cover, COM input test lead, protective casing, test lead fixture, and test leads.

Diagram showing button functions and parts of the GOLDCHAMP GC-EU-38A Voltage Penguji

Rajah 5.2: Terperinci view of the probe cover, test leads, battery compartment, LED light, and the main display.

5.2 Jldtage Pengukuran (AC/DC)

The tester automatically detects AC or DC voltage. Connect the test probes to the circuit or component you wish to measure. The voltage will be displayed on the LCD, and corresponding LED indicators will light up.

  • LED Indication Voltage Ujian:
    Voltage Range: 12-690V AC/DC
    Nominal Voltage (European): 12/24/50/120/230/400/690V
    Toleransi (Ambang Voltage) Light ON at more than:
        - 7 ± 5V (12V LED)
        - 18 ± 5V (24V LED)
        - 37.5 ± 5V (50V LED)
        - 75% ± 5% of nominal voltage (120/230/400/690V)
    Response Time: <0.5s at 100% of each nominal voltage
  • LCD Display Voltage Ujian:
    Range / Resolution: 7-690V / 1V (Auto-Range)
    Accuracy (23 ± 5°C): (3% + 3) or 5V
    Overrange Indication: All Voltage LEDs light up
    Response Time: <1s at 90% of each voltage

5.3 Ujian Kesinambungan

To perform a continuity test, select the continuity function (if applicable via the SELECT button). Connect the test probes across the component or circuit. A buzzer will sound, and an LED indicator will light up if continuity is detected.

  • Detection Range: 0-550KΩ (±200K)
  • Test Current: Approximately 1.5uA (3V battery, 0Ω)

5.4 Phase Rotation Test

This function is used for three-phase AC systems.

  • System: Three-phase 4-wire AC system
  • Kekerapan: 50Hz ~ 60Hz
  • Phase Range: 120 ± 5 degrees

5.5 Fungsi Lampu Suluh

Press and hold the 'PEN' button for 2 seconds to activate the built-in flashlight. This feature is useful for illuminating dark work areas. The flashlight will typically turn off automatically after a short period or by pressing the button again.

Image showing data hold function and flashlight use on the GOLDCHAMP GC-EU-38A

Figure 5.3: The top light can function even at night, and the data hold feature locks the measured value on the LCD.

5.6 Fungsi Pegangan Data

Once stable data is measured, the instrument will lock the value on the LCD screen, which is convenient for reading. The instrument will automatically turn off after 15 seconds if no further action is taken.

GOLDCHAMP GC-EU-38A Voltage Tester in various usage scenarios

Figure 5.4: The GOLDCHAMP GC-EU-38A in use for AC voltage testing in a wall socket and DC voltage testing in an automotive application.

GOLDCHAMP GC-EU-38A Voltage Tester performing a phase sequence test on a circuit breaker panel

Figure 5.5: Performing a phase sequence test on a three-phase circuit breaker panel.

6. Penyelenggaraan

6.1 Pembersihan

To clean the instrument, wipe the casing dengan iklanamp cloth and a mild detergent. Do not use abrasives or solvents. Ensure the instrument is completely dry before use.

6.2 Penggantian Bateri

When the low battery indicator appears on the display, or if the power indicator blinks/goes out during self-test, replace the batteries as described in Section 4.2. Always use two new 1.5V AA batteries.

6.3 Penyimpanan

If the instrument is not used for a long period, remove the batteries to prevent leakage and damage. Store the tester in a cool, dry place, away from direct sunlight and extreme temperatures.

7. Penyelesaian masalah

  • No Display/Instrument Not Turning On:
    Check battery installation and polarity. Replace batteries if they are low or depleted.
  • Bacaan Tidak Tepat:
    Ensure test probes are making good contact. Verify the instrument's functionality on a known live source. Check for any physical damage to the instrument or leads.
  • LEDs Not Lighting Up Correctly:
    Ensure the ambient temperature is within the specified range (-10°C to 55°C). If all voltage LEDs light up, it indicates an over-range condition.
  • Continuity Test Not Working:
    Ensure the continuity function is selected (if applicable). Check for open circuits or high resistance.

8. Spesifikasi Teknikal

SpesifikasiNilai
PengeluarGOLDCHAMP
Nombor Model ItemGC-EU-38A
Dimensi Produk (L x W x H)25.1 x 7.7 x 2.8 cm; 250 gram
Bateri2 AA - disertakan
JenamaGOLDCHAMP
Sumber KuasaDikuasakan Bateri
GayaPadat
warnaBiru
Penarafan Suhu Lebih Rendah6 Darjah Celsius
Vol. Operasi Minimumtage12 Volt
Spesifikasi yang MematuhiCE, IP64, CAT III 690V, CAT IV 600V
Penarafan Suhu Atas55 Darjah Celsius
Jenis PengukuranVoltmeter
GOLDCHAMP GC-EU-38A Voltage Tester showing dustproof rating and detailed specifications

Figure 8.1: Detailed specifications including LED indication voltage test, LCD display voltage test, and dustproof rating (IP61, note: product description states IP64/IP65).

9. Waranti dan Sokongan

For any questions or assistance, please contact GOLDCHAMP customer service. We are committed to responding within 24 hours.

Maklumat Hubungan: Please refer to the product packaging or the official GOLDCHAMP webtapak untuk butiran hubungan sokongan pelanggan terkini.

© 2026 GOLDCHAMP. Semua hak terpelihara.