1. Pengenalan

The Xetron STC-1000Pro is a versatile digital temperature controller designed for precise temperature management in various environments. It features dual outlets for simultaneous heating and cooling control, a wide temperature range, and user-friendly operation. This manual provides detailed instructions for setting up, operating, and maintaining your device.

Xetron STC-1000Pro Digital Temperature Controller with power cord, sensor, and dual outlets

Figure 1: Xetron STC-1000Pro Digital Temperature Controller. This image displays the main unit with its digital display, control buttons, power cord, temperature sensor, and the dual-outlet power strip for heating and cooling devices.

Aplikasi

The STC-1000Pro is suitable for a wide range of applications requiring accurate temperature control, including:

  • Reptile enclosures and terrariums
  • Home brewing and fermentation
  • Inkubator
  • Rumah hijau
  • Akuarium
  • Peti sejuk
Various applications of the Xetron STC-1000Pro controller

Figure 2: Common applications for the Xetron STC-1000Pro. This image illustrates the controller's use in home brewing, incubators, aquariums, and flower cultivation, highlighting its versatility.

2. Ciri-ciri Utama

  • Ideal Temperature Control: Two outlets allow simultaneous or separate connection of heating and cooling equipment for automatic temperature switching. Wide control range of -40 to 230 ℉ (-40 to 110 ℃) with a temperature accuracy of Β±1 ℃ / Β±2 ℉.
  • Reka Bentuk Mesra Pengguna: Simple 3-button operation and pre-wired design for plug-and-play functionality. Large display for easy real-time data reading.
  • Sistem Penggera Dwi: Adjustable high/low temperature alarms with audible beeps and a bell icon on the display, ensuring timely alerts even when not near the device.
  • Parameter Boleh Disesuaikan: Supports settings for ℃/℉ unit switching, temperature calibration, high and low alarm values, start delay, and protection time (cooling mode only).
  • Keselamatan dan Kualiti: Constructed from V-0 flame-retardant ABS material. Features compressor delay protection and complies with CE and FCC standards for safe operation.
  • Probe Kalis Air IP65: The temperature probe head can be immersed in fresh water, and the main unit features an internal rubber ring to prevent water ingress.
Xetron STC-1000Pro maintaining temperature range

Figure 3: Temperature control range of the Xetron STC-1000Pro. This image highlights the controller's ability to maintain temperatures within a desired range of -40 to 230 ℉ using both cooling and heating devices.

Xetron STC-1000Pro large screen display with dimensions

Figure 4: Large screen display of the Xetron STC-1000Pro. The image shows the display dimensions and labels for PV (Present Value), SV (Set Value), Csp (Cooling Start Point), and Hsp (Heating Start Point), indicating ℃/℉ switchability.

Xetron STC-1000Pro visual and audible alerts

Figure 5: Visual and audible alert features. This image illustrates the double alarm and delay protection functionalities of the controller, enhancing safety and monitoring.

Xetron STC-1000Pro safety certifications

Figure 6: Safety and quality certifications. The image highlights the V-0 flame-retardant ABS material and compliance with CE, FCC, and RoHS standards, ensuring product safety.

Xetron STC-1000Pro IP65 waterproof probe

Figure 7: IP65 waterproof features. This image demonstrates the waterproof capability of the temperature probe, which can be immersed in fresh water, and the internal rubber ring for main unit protection.

3. Arahan Persediaan

  1. Buka bungkusan Peranti: Carefully remove the Xetron STC-1000Pro controller and its components from the packaging.
  2. Sambungkan Sensor: Ensure the temperature sensor is fully inserted into its dedicated port on the side of the controller. A loose connection can lead to "ERR" display.
  3. Letakkan Penderia: Place the temperature probe in the environment where temperature monitoring and control are required. Ensure it is not directly exposed to heating or cooling elements to get an accurate reading.
  4. Sambungkan Peranti Pemanasan/Penyejukan:
    • Pasangkan peranti pemanas anda (cth., pemanasamp, heating mat) into the socket labeled "HEATING".
    • Plug your cooling device (e.g., fan, chiller) into the socket labeled "COOLING".

    Penting: The maximum output for each socket is 10A at 240VAC. Do not connect high-power equipment exceeding these limits.

  5. Hidupkan kuasa: Plug the controller's main power cord into a standard 230V AC power outlet. The display will illuminate, showing the current temperature (PV) and other settings.
Xetron STC-1000Pro plug and play setup

Figure 8: Plug-and-play setup of the Xetron STC-1000Pro. This image demonstrates the simplicity of connecting the controller, showing it mounted on a wall next to a terrarium, with heating/cooling devices plugged in.

4. Arahan Operasi

The STC-1000Pro features a simple 3-button interface: SET, ATAS (β–²), dan TURUN (β–Ό).

4.1 Paparan Terlaluview

  • PV (Present Value): Displays the current measured temperature.
  • SV (Nilai Tetap): Displays the target temperature you wish to maintain.
  • Csp (Cooling Start Point): The temperature at which the cooling device will activate.
  • Hsp (Heating Start Point): The temperature at which the heating device will activate.

4.2 Menetapkan Suhu Sasaran (SV)

  1. Tekan ke SET button once. The SV value will flash.
  2. Gunakan ATAS (β–²) or TURUN (β–Ό) butang untuk melaraskan suhu sasaran.
  3. Tekan SET again to confirm and save the setting, or wait a few seconds for it to save automatically.

4.3 Tetapan Parameter Lanjutan

To access advanced settings, press and hold the SET button for approximately 3 seconds until the display changes to show parameter codes.

Xetron STC-1000Pro parameter setting diagram

Figure 9: Diagram illustrating parameter settings. This image shows the relationship between TS (Temperature Set-point), CD (Cooling Differential), HD (Heating Differential), Csp (Cooling Start Point), and Hsp (Heating Start Point).

Gunakan ATAS (β–²) or TURUN (β–Ό) buttons to navigate through the parameters. Press SET to enter a parameter's value, then use ATAS (β–²) or TURUN (β–Ό) to adjust, and SET sekali lagi untuk berjimat.

Table 1: Advanced Parameters
ParameterPeneranganJulatLalai
TS (Temperature Set-point)The desired target temperature (same as SV).-40 to 110 ℃ / -40 to 230 ℉Berbeza-beza
CD (Cooling Differential)The difference between the cooling start point (Csp) and the set temperature (TS). Cooling activates when PV β‰₯ TS + CD.0.1 to 30 ℃ / 0.1 to 54 ℉2 ℃ / 3.6 ℉
HD (Heating Differential)The difference between the heating start point (Hsp) and the set temperature (TS). Heating activates when PV ≀ TS - HD.0.1 to 30 ℃ / 0.1 to 54 ℉2 ℃ / 3.6 ℉
PT (Protection Time)Compressor delay protection time (in minutes) for cooling mode only. Prevents frequent compressor cycling.0 hingga 10 minit3 minit
CA (Temperature Calibration)Adjusts the temperature reading to match an external reference thermometer.-10 to 10 ℃ / -18 to 18 ℉0 ℃ / 0 ℉
CF (Unit Switch)Switches between Celsius (℃) and Fahrenheit (℉).C / FC
HA (High Alarm)Sets the upper temperature limit for the alarm.TS to 110 ℃ / TS to 230 ℉110 ℃ / 230 ℉
LA (Low Alarm)Sets the lower temperature limit for the alarm.-40 ℃ / -40 ℉ to TS-40 ℃ / -40 ℉

After adjusting parameters, press and hold SET again for 3 seconds to exit the advanced settings menu and return to normal operation.

5. Penyelenggaraan

  • Pembersihan: Disconnect the power before cleaning. Wipe the controller's surface with a soft, damp cloth. Do not use abrasive cleaners or immerse the main unit in water. The temperature probe can be cleaned with water.
  • Storan: Store the device in a dry environment within the temperature range of -20 ℃ to 75 ℃ (-4 ℉ to 167 ℉) to ensure the longest possible lifespan.
  • Penjagaan Sensor: Ensure the temperature sensor cable is not pinched or damaged. A damaged sensor can lead to inaccurate readings or error messages.

6. Penyelesaian masalah

Jadual 2: Panduan Penyelesaian Masalah
MasalahKemungkinan PuncaPenyelesaian
"ERR" displayed on screenTemperature sensor not fully inserted or damaged; temperature exceeds measurement range.Ensure the sensor is fully inserted into its port. If the issue persists, the sensor may be faulty and require replacement. If the temperature is outside the -40 to 110 ℃ range, the controller will display "ERR".
Alarm sounds and bell icon appearsCurrent temperature (PV) has exceeded the set high alarm (HA) or fallen below the low alarm (LA) threshold.Check the environmental conditions. Adjust HA/LA settings if necessary. The controller will disable all outputs in fault alarm mode to protect equipment.
Peranti Pemanas/Penyejukan tidak diaktifkanIncorrect temperature settings (TS, CD, HD); compressor delay protection (PT) active; device not properly plugged in; device malfunction.Verify TS, CD, and HD settings. Wait for the PT delay to expire in cooling mode. Ensure devices are securely plugged into the correct outlets. Test heating/cooling devices independently.
Bacaan suhu tidak tepatSensor placement; temperature calibration (CA) offset.Relocate the sensor to a more representative area. Use the CA parameter to calibrate the reading against a known accurate thermometer.

7. Spesifikasi

Jadual 3: Spesifikasi Produk
CiriPerincian
Nombor ModelXT-STC1000Pro-01US
JenamaXetron
Voltage230V AC (Note: Product description mentions 230V, specifications mention 110V. User should verify their specific model's voltage requirements.)
Arus Output Maksimum10A setiap soket
Julat Kawalan Suhu-40 ℃ hingga 110 ℃ (-40 ℉ hingga 230 ℉)
Ketepatan SuhuΒ±1 ℃ / Β±2 ℉
Jenis PaparanOLED
bahanFlame-retardant ABS Plastic
Dimensi Produk (L x W x H)20 x 15 x 6 cm
Berat badan400 gram
Suhu OperasiUp to 110 ℃
Komponen yang Disertakan1x Temperature Controller

8. Amaran dan Langkah Berjaga-jaga Keselamatan

  • Beban Elektrik: Do not connect equipment with a total power consumption exceeding 10A (2400W at 240V) to each outlet. Overloading can cause damage to the controller and connected devices, and poses a fire hazard.
  • Voltage Keserasian: Ensure the controller's voltage (230V) sepadan dengan bekalan kuasa tempatan anda.
  • Pendedahan Air: While the probe is waterproof, the main controller unit is not designed for immersion. Avoid exposing the main unit to direct water spray or submersion.
  • Integriti Sensor: Always ensure the temperature sensor is fully and securely inserted. A short-circuited or damaged sensor will trigger a fault alarm and disable outputs for protection.
  • Kanak-kanak dan Haiwan Kesayangan: Keep the device and its cables out of reach of children and pets to prevent accidental damage or injury.
  • Pengudaraan: Pastikan pengudaraan yang mencukupi di sekitar pengawal untuk mengelakkan terlalu panas.