VIVIDIA CT-6010

Vividia CT-6010 LCD/WiFi Flexible Two-Way Articulating Inspection Camera Borescope Videoscope User Manual

Model: CT-6010

pengenalan

This manual provides essential information for the safe and effective use of your Vividia CT-6010 LCD/WiFi Flexible Two-Way Articulating Inspection Camera Borescope Videoscope. Please read these instructions carefully before operating the device and retain them for future reference.

Vividia CT-6010 Borescope main unit with flexible probe

Figure 1: Vividia CT-6010 Borescope main unit with flexible probe.

Persediaan

1. Membongkar dan Pengenalan Komponen

Carefully unpack all items from the packaging. Ensure all components are present and undamaged. The package typically includes:

  • Vividia CT-6010 Main Unit with LCD Display
  • Flexible Articulating Probe (6mm diameter, 1.0m length)
  • Penyesuai Kuasa/Pengecas
  • Kabel USB
  • Membawa Sarung
  • Tali Bahu
Vividia CT-6010 Borescope kit contents including main unit, probe, charger, and case

Figure 2: Contents of the Vividia CT-6010 package.

2. Mengecas Peranti

Before first use, fully charge the device. Connect the power adapter to the DC Masuk port on the main unit and plug it into a power outlet. The charging indicator will show the charging status.

sebelah view of Vividia CT-6010 main unit showing SD card slot, USB port, and DC In charging port

Figure 3: DC In port for charging, along with SD and USB ports.

3. Memasukkan Kad SD

To save photos and videos, insert a compatible Micro SD card (not included) into the SD card slot on the side of the main unit. Ensure the card is inserted correctly until it clicks into place.

4. Menghidupkan/Mematikan

Tekan dan tahan butang kuasa button located on the control panel to turn the device on or off. The LCD screen will illuminate upon startup.

5. WiFi Connection (Optional)

The CT-6010 features built-in WiFi for connecting to iPhone, iPad, or Android devices. Follow these steps:

  1. Turn on the CT-6010 device.
  2. Dayakan WiFi pada peranti mudah alih anda.
  3. Cari untuk the CT-6010's WiFi network (usually named 'Vividia_XXXX').
  4. Connect to the network using the provided password (refer to the device screen or a sticker on the unit).
  5. Open the dedicated Vividia app on your mobile device to view the live feed and control functions.
Vividia CT-6010 connected via WiFi to a smartphone

Gambar 4: Cthample of WiFi connection to a mobile device.

Arahan Operasi

1. Kawalan Asas

The main unit features several buttons for operation:

  • Butang Kuasa: Menghidupkan/mematikan peranti.
  • Butang OK: Confirms selections in the menu or captures media.
  • Butang Menu: Mengakses tetapan peranti.
  • Butang Cahaya (*): Adjusts the brightness of the LED lights on the probe tip.
  • Photo/Video Capture Button: A dedicated button on the handle for quick photo or video recording.
Close-up of Vividia CT-6010 handle showing the Photo/Video Capture button

Figure 5: Location of the Photo/Video Capture button.

2. Probe Articulation

The CT-6010 features a two-way articulating probe. Use the articulation knob on the handle to precisely control the bending direction of the probe tip. The probe can bend more than 180 degrees in two directions, allowing for comprehensive inspection of hard-to-reach areas.

Series of images showing the flexible probe tip articulating in different directions

Gambar 6: Cthamples of probe articulation.

Terperinci view of the probe tip bending mechanism

Figure 7: Close-up of the articulating probe tip.

3. Adjusting Illumination

Tekan ke * (Light) button to cycle through different brightness levels for the LED lights at the probe tip. Adjust the illumination to achieve optimal visibility in various inspection environments.

4. Menangkap Foto dan Video

manakala viewing the live feed, press the Butang Tangkap Foto/Video on the handle to take a still image. To record a video, press and hold the button briefly to start recording, and press it again to stop. Captured media is saved to the inserted SD card.

Image showing an inspection view of internal machinery components through the borescope

Gambar 8: Cthample of an inspection view.

5. Navigasi dan Tetapan Menu

Tekan ke Menu button to access device settings. Use the directional buttons (often integrated with OK/Light buttons) to navigate through options such as resolution, date/time, language, and playback. Press OK to confirm selections and Menu lagi untuk keluar.

Penyelenggaraan

1. Pembersihan

  • Siasatan: Selepas setiap penggunaan, lap probe dan kanta kamera dengan lembutamp cloth. For stubborn dirt, use a mild cleaning solution. Ensure no liquid enters the main unit.
  • Unit Utama: Wipe the main unit with a dry, soft cloth. Avoid using abrasive cleaners or solvents.

2. Penjagaan Bateri

Untuk memanjangkan hayat bateri:

  • Charge the device fully before long periods of storage.
  • Elakkan menyimpan peranti dalam persekitaran yang sangat panas atau sejuk.
  • If not used for an extended period, charge the battery every 3-6 months.

3. Penyimpanan

Store the CT-6010 in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure the probe is coiled loosely and not sharply bent to prevent damage.

4. Tahan Air

The flexible probe is rated IP67 waterproof, meaning it can withstand immersion in water up to 1 meter for 30 minutes. The main unit is NOT waterproof. Do not immerse the main unit in water or expose it to heavy rain.

Menyelesaikan masalah

MasalahKemungkinan PuncaPenyelesaian
Peranti tidak dihidupkan.Bateri lemah; Butang kuasa tidak ditekan dengan betul.Charge the device fully; Press and hold the Power button for a few seconds.
Tiada imej pada skrin.Probe not connected properly; Camera lens obstructed/dirty.Ensure the probe is securely connected; Clean the camera lens.
Sambungan WiFi gagal.Incorrect password; App not installed; Device out of range.Verify WiFi password; Install the correct Vividia app; Move closer to the device.
Probe articulation is stiff or stuck.Obstruction; Mechanical issue.Do not force the articulation. Gently retract the probe and check for obstructions. If the issue persists, contact support.
Kualiti gambar yang buruk.Insufficient lighting; Dirty lens; Incorrect focus (if adjustable).Adjust LED brightness; Clean the camera lens; Ensure proper distance from object.

Spesifikasi

CiriPerincian
Diameter Probe6mm (0.236 inci)
Panjang Probe1.0 meter (3.3 kaki)
Resolusi KameraHD 1280x720
Artikulasi2-way, max. bending angle >180 degrees
KetersambunganBuilt-in WiFi (for iPhone, iPad, Android)
Penilaian Kalis AirIP67 (probe only)
PaparanLCD Bersepadu
Resolusi Tangkapan Video720p
Denyar KameraLED Terbina Dalam
PengeluarTeknologi Vividia
Tarikh Mula-mula Tersedia12 Januari 2022
Digital caliper measuring the 6mm diameter of the borescope probe

Figure 9: Probe diameter measurement.

Diagram illustrating the 3.3 ft / 1 meter length of the borescope probe

Figure 10: Probe length illustration.

Waranti dan Sokongan

Maklumat Waranti

The Vividia CT-6010 is covered by a manufacturer's warranty. Please refer to the warranty card included with your product or visit the official Vividia Technologies webtapak untuk terma dan syarat jaminan terperinci.

Sokongan Pelanggan

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact Vividia Technologies customer support. Contact information can typically be found on the manufacturer's webtapak atau dalam dokumentasi produk anda.