deleyCON MK5036
deleyCON Mechanical Timer Instruction Manual
Model: MK5036
1. Pengenalan
The deleyCON mechanical timer allows for automatic ON/OFF switching of electrical devices. It features a manual adjustable dial for precise control and can be set in 15-minute intervals, providing up to 96 switching operations per day. This timer is designed for indoor use and is equipped with integrated child protection, making it ideal for controlling lights, fans, aquariums, and other household appliances.
2. Arahan Keselamatan
- Always ensure the timer is correctly plugged into a standard earthed socket (220-240V AC, 50Hz).
- Do not exceed the maximum load capacity of 16(2)A or 3500W. Overloading can cause damage or fire.
- This timer is designed for indoor use only (IP20 protection class). Do not expose it to moisture, rain, or extreme temperatures.
- Do not connect multiple timers in series.
- Do not disassemble or modify the timer. Refer all servicing to qualified personnel.
- Keep out of reach of children. The integrated child protection helps prevent accidental access to live parts.
- To disconnect power, always pull the plug from the wall socket.
- The mechanical switching segments may produce an audible clicking sound during operation. This is normal.
3. Produk Lebihview
Familiarize yourself with the components of your deleyCON mechanical timer:




- 24-Hour Dial: The large rotating dial with numbers 1-24 represents the hours of the day.
- Switching Segments: The small black pins around the dial. Each pin represents 15 minutes. Pushing a pin outwards sets that 15-minute interval to "ON". Pushing it inwards sets it to "OFF".
- Current Time Indicator: A small arrow or mark on the stationary part of the timer, indicating the current time on the dial.
- Suis Override Manual: Located on the side, this switch allows you to bypass the timer function.
- "I" (ON) Position: The connected device will remain continuously ON, regardless of the timer settings.
- Clock Symbol (Timer) Position: The connected device will operate according to the programmed ON/OFF cycles.
- Soket: The central outlet where you plug in the device to be controlled.
- Palam: The prongs on the back of the timer for plugging into a wall socket.
4. Persediaan
- Tetapkan Masa Semasa:
Rotate the 24-hour dial clockwise until the current time aligns with the current time indicator arrow on the timer's body. For example, if it's 3 PM, align the '15' mark with the arrow.

Rajah 4.1: Setting the current time by rotating the dial. - Program ON/OFF Cycles:
Identify the time periods when you want the connected device to be ON. For each desired ON period, push the corresponding black segments (pins) outwards. Each segment represents 15 minutes. If you want a device to be ON for an hour (e.g., from 7:00 AM to 8:00 AM), push out all four segments between '7' and '8' on the dial.
Segments that are pushed inwards will keep the device OFF during those times.
- Set Manual Override Switch:
Ensure the manual override switch on the side of the timer is set to the Simbol Jam position. This activates the timer function. If set to "I", the timer will be continuously ON.
- Pasangkan:
Plug the deleyCON mechanical timer into a wall socket. Then, plug the device you wish to control into the timer's socket.
5. Operating the Timer
Once set up, the timer will automatically switch your connected device ON and OFF according to your programmed schedule. The dial will continuously rotate clockwise, indicating the current time.

- Operasi Berterusan: If you need the device to be continuously ON, simply slide the manual override switch to the "I" position. The timer will still rotate, but the output will remain active.
- Returning to Timer Mode: To resume scheduled operation, slide the manual override switch back to the Simbol Jam kedudukan.
- Jadual Pelarasan: To change the ON/OFF times, simply push the desired segments inwards or outwards. No need to reset the current time unless the timer has been unplugged for an extended period.
6. Penyelenggaraan
- Keep the timer clean by wiping it with a dry, soft cloth. Do not use liquid cleaners or abrasive materials.
- Ensure the timer is unplugged from the wall socket before cleaning.
- Simpan pemasa di tempat yang kering apabila tidak digunakan.
7. Penyelesaian masalah
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Peranti tidak HIDUP/MATI pada waktu yang diprogramkan. |
|
|
| Timer dial is not rotating. |
|
|
| Bunyi klik yang boleh didengar. | Normal operation of mechanical switching segments. | No action required. This is normal for mechanical timers. |
8. Spesifikasi
| Ciri | Perincian |
|---|---|
| Nombor Model | MK5036 |
| Input Voltage | 220-240V AC, 50Hz |
| Maks. Muatkan | 16(2)A, 3500W |
| Minimum Switching Interval | 15 minit |
| Menukar Kitaran | 96 per day (4 per hour) |
| Kelas Perlindungan | IP20 (Penggunaan dalaman sahaja) |
| Perlindungan Kanak-kanak | Bersepadu |
| warna | putih |
| Dimensi (lebih kurang) | 8.5D x 8W x 8H cm |
| Berat (lebih kurang) | 262 Gram |
9. Waranti dan Sokongan
For any questions, technical support, or warranty claims, please contact your retailer or deleyCON customer service. Please refer to the product model number MK5036 when contacting support.
Further information may be available on the official deleyCON webtapak: www.deleycon.com