1. Pengenalan
Welcome to the EPEVER IPower-Plus Series IP3000-12 Plus Pure Sine Wave Inverter. This manual provides essential information for the safe and efficient operation of your inverter. The IPower-Plus series is designed to convert 12V DC battery power into 230V AC pure sine wave electricity, suitable for various applications including off-grid home emergency lighting and vehicle-mounted systems.
Key features include a 180-degree rotatable LCD display, compatibility with lithium batteries, and a USB output port. The inverter incorporates surge current suppression technology to protect lithium battery cells and the Battery Management System (BMS) from damage caused by high inrush currents. It also features low idle loss and a sleep mode for enhanced energy efficiency.
2. Arahan Keselamatan
WARNING: Failure to follow these safety instructions may result in serious injury, death, or damage to the inverter and other equipment.
- Read this entire manual before installation and operation.
- Pemasangan hendaklah dilakukan oleh pegawai yang berkelayakan.
- Pastikan pengudaraan yang betul di sekeliling penyongsang untuk mengelakkan terlalu panas.
- Do not expose the inverter to water, rain, snow, or any liquids.
- Connect the inverter to a battery bank with the correct voltage (12V DC).
- Observe correct polarity when connecting DC input cables (+ to + and - to -). Reverse polarity will cause damage.
- Pastikan semua sambungan ketat dan kukuh untuk mengelakkan sambungan longgar dan lengkungan.
- Do not connect the inverter to an AC utility grid or other AC power sources.
- Avoid short-circuiting the AC output.
- Keep flammable materials away from the inverter.
- Jangan buka penyongsang casing; tiada bahagian yang boleh diservis pengguna di dalamnya.
- Sentiasa putuskan sambungan kuasa sebelum melakukan sebarang penyelenggaraan atau pembersihan.
3. Produk Lebihview
3.1 Ciri-ciri
- Output Gelombang Sinus Tulen: Menyediakan kuasa AC berkualiti tinggi yang sesuai untuk elektronik sensitif.
- 180-Degree Rotatable LCD Display: Membolehkan untuk fleksibel viewing angles of operational data.
- Lithium Battery Compatibility: Designed to work effectively with lithium battery systems.
- Output USB: Integrated 5VDC / Max.1A USB port for charging small devices.
- Surge Current Suppression: Protects battery cells and BMS from high inrush currents.
- Low Idle Loss / Sleep Mode: Minimizes power consumption when no load or light load is present.
- Isolated RS485 Communication Interface: (Optional) Enables remote monitoring, management, and settings adjustment via PC software or mobile app.
3.2 Komponen
The EPEVER IPower-Plus Series IP3000-12 Plus inverter includes the main unit and necessary connection accessories.

Rajah 1: Depan view of the EPEVER IPower-Plus Series IP3000-12 Plus Pure Sine Wave Inverter. This image shows the main body of the inverter with its LCD display and branding.

Figure 2: Rear panel of the EPEVER IPower-Plus Series IP3000-12 Plus inverter. This view highlights the DC input terminals, AC output terminals, USB port, and RS485 communication port.

Rajah 3: Bawah view of the EPEVER IPower-Plus Series IP3000-12 Plus inverter, showing the integrated cooling fans for thermal management.
Komponen yang Disertakan:
- Unit Penyongsang
- RS485 Communication Port (integrated)
- USB Output (integrated)
- Kabel Tanah
- Kabel Input DC
- Kabel Output AC
4. Persediaan
4.1 Membongkar dan Pemeriksaan
- Buka bungkusan inverter dan semua aksesori dengan berhati-hati.
- Inspect the unit for any visible damage that may have occurred during shipping. Contact your supplier if any damage is found.
- Sahkan bahawa semua komponen yang disenaraikan dalam Bahagian 3.2 ada.
4.2 Pemasangan
- Pilih lokasi yang kering dan mempunyai pengudaraan yang baik, jauh daripada cahaya matahari langsung, sumber haba dan kelembapan.
- Ensure there is sufficient clearance around the inverter for proper airflow, especially around the cooling fans.
- Mount the inverter securely to a stable surface using appropriate fasteners. The mounting dimensions are 532 x 145mm.
4.3 Sambungan Pendawaian
CAUTION: Before making any connections, ensure the inverter is switched OFF and the battery bank is disconnected or fused.
- Pembumian: Connect the ground terminal of the inverter to an earth ground point using the provided ground cable. This is crucial for safety.
- Sambungan Input DC:
- Connect the positive (+) terminal of your 12V DC battery bank to the positive (+) DC input terminal on the inverter.
- Connect the negative (-) terminal of your 12V DC battery bank to the negative (-) DC input terminal on the inverter.
- Use appropriate cable gauge for the DC input to minimize voltage drop and ensure safe operation.
- Sambungan Output AC:
- Connect your AC loads (appliances) to the AC output terminals of the inverter.
- Ensure the total power consumption of your AC loads does not exceed the inverter's continuous power rating (3000W).
- Optional Connections (RS485 & USB):
- If using the RS485 communication feature, connect the RS485 cable to the designated port for remote monitoring.
- The USB port can be used to charge compatible 5VDC devices.
5. Arahan Operasi
5.1 Menghidupkan Penyongsang
- After all connections are securely made and verified, connect the battery bank (if not already connected).
- Switch on the DC input breaker or fuse, if installed.
- Press the power button on the inverter. The LCD display will illuminate, indicating the inverter is operational.
- The inverter will begin converting DC power to AC power.
5.2 Mematikan Inverter
- Turn off all connected AC loads.
- Press and hold the power button on the inverter until the display turns off.
- Switch off the DC input breaker or fuse, and disconnect the battery bank if the inverter will not be used for an extended period.
5.3 Paparan LCD
The LCD display provides real-time operational data. It can be rotated 180 degrees for optimal viewing. Information typically displayed includes:
- Input DC Voltage
- Keluaran AC Voltage
- Kuasa Output (Watts)
- Kekerapan Output (Hz)
- Status Bateri
- Kod Ralat (jika ada)
6. Penyelenggaraan
Penyelenggaraan berkala memastikan jangka hayat dan prestasi optimum inverter anda.
- Pembersihan: Periodically clean the exterior of the inverter with a dry cloth to remove dust and debris. Ensure cooling vents are clear. Do not use liquid cleaners.
- Pemeriksaan Sambungan: Annually inspect all electrical connections (DC input, AC output, ground) to ensure they are tight and free from corrosion. Loose connections can cause overheating and damage.
- Pengudaraan: Ensure the area around the inverter remains clear and well-ventilated. Check that the cooling fans are operating correctly when the inverter is under load.
- Penyelenggaraan Bateri: Follow the manufacturer's guidelines for your specific battery type. Ensure batteries are properly charged and maintained to prolong their lifespan and ensure stable power supply to the inverter.
7. Penyelesaian masalah
Bahagian ini menggariskan isu-isu biasa dan potensi penyelesaiannya. Jika masalah berterusan, hubungi khidmat pelanggan.
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| No AC Output / Inverter not turning on | Bateri rendah voltage Loose DC connections Inverter switch off Blown DC fuse/breaker | Charge battery or check battery health Check and tighten all DC connections Hidupkan suis penyongsang Check and replace fuse/reset breaker |
| Overload Alarm / Shutdown | Connected load exceeds inverter rating High inrush current from inductive loads | Reduce total connected load Start inductive loads one at a time; consider a higher capacity inverter if frequent |
| Overheating Alarm / Shutdown | Pengudaraan yang lemah Suhu persekitaran yang berlebihan Continuous high load | Ensure clear airflow around inverter Relocate inverter to a cooler environment Reduce load or operate intermittently |
| Abnormal AC Output Voltage / Kekerapan | Input DC rendah voltage Faulty inverter | Semak bateri voltage dan sambungan Hubungi sokongan pelanggan |
| Port USB Tidak Berfungsi | Overload on USB port Faulty USB device | Disconnect and reconnect USB device Try a different USB device |
7.1 Fungsi Perlindungan
The inverter is equipped with extensive protection features:
- Perlindungan Polariti Terbalik: Prevents damage from incorrect DC input wiring.
- Lebih-voltage Perlindungan: Shuts down if DC input voltage melebihi had selamat.
- Di bawah voltage Perlindungan: Shuts down to protect batteries from over-discharge.
- Perlindungan Lebihan: Shuts down if AC output load exceeds rated capacity.
- Perlindungan litar pintas: Protects against damage from AC output short circuits.
- Perlindungan lebih suhu: Ditutup jika suhu dalaman menjadi terlalu tinggi.
8. Spesifikasi
| Parameter | Nilai |
|---|---|
| Bateri Sistem Voltage | 12V DC |
| Kuasa Berterusan | 3000W |
| Surge Power (5s) | 6000W |
| Keluaran AC Voltage | 220VAC (±3%); 230VAC (-7% ~ +3%) |
| Kekerapan Output | 50 / 60Hz ±0.2% |
| Kecekapan Maksimum | >94% (30% load) |
| Arus Tanpa Beban | <1.6A |
| Output USB | 5VDC / Max.1A |
| RS485 Interface Output | 5VDC / 200mA |
| Kelas Perlindungan | IP20 |
| Dimensi (L x W x H) | 557 × 231.5 × 123mm |
| Dimensi Pemasangan | 532 x 145mm |
| Berat Bersih | 10.5kg |
| Bentuk Gelombang Output | Gelombang Sinus Tulen |
| Pensijilan | CE, RoHS |
9. Waranti dan Sokongan
9.1 Maklumat Waranti
The EPEVER IPower-Plus Series IP3000-12 Plus Pure Sine Wave Inverter comes with a Waranti pengilang selama 2 tahun dari tarikh pembelian. Waranti ini melindungi kecacatan pada bahan dan mutu kerja di bawah penggunaan dan perkhidmatan biasa.
Waranti tidak meliputi:
- Kerosakan yang disebabkan oleh pemasangan atau pendawaian yang tidak betul.
- Kerosakan yang disebabkan oleh pembaikan atau pengubahsuaian yang tidak dibenarkan.
- Damage caused by natural disasters, accidents, or misuse.
- Damage from operating the inverter outside its specified environmental limits.
9.2 Sokongan Teknikal
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact your EPEVER dealer or the official EPEVER customer support channel. Please have your product model number and purchase information ready when contacting support.