pengenalan
The Fysic FL-30LED LED Table Magnifying Lamp is designed to provide illuminated magnification for various tasks requiring detailed vision. This manual provides essential information for the safe and effective use of your magnifying lamp, memastikan prestasi optimum dan umur panjang.
Arahan Persediaan
- Buka bungkusan Lamp: Carefully remove all components from the packaging. Ensure no parts are missing or damaged.
- Letakkan Lamp: Letakkan lamp on a stable, flat surface such as a table or desk.
- Sambungkan Kuasa: Insert the power plug into a suitable electrical outlet (220-240V). The lamp features an extra-long 2.5-meter cable for convenience.

Image: The Fysic FL-30LED lamp in a compact, folded position, ready for placement.

Image: Close-up of the power plug for the Fysic FL-30LED lamp.
Arahan Operasi
- Hidupkan/Mati Kuasa: Locate the power switch on the base of the lamp. Press the switch to turn the LED light on or off.
- Melaraskan Lengan: Lamp features a sturdy, articulated arm. Gently adjust the arm to position the magnifying lens and light source over your work area at the desired height and angle. The arm is designed to hold its position once set.
- Using the Magnifying Lens: Position your object or reading material under the 5-diopter (2.25x) magnifying lens. Adjust the distance between the lens and the object until the image is clear and in focus.
- Perlindungan Lensa: When not in use, place the included protective cap over the magnifying lens to prevent dust and scratches.

Image: The Fysic FL-30LED lamp with its arm extended and lens cover open, demonstrating its operational position.

Image: A person using the Fysic FL-30LED lamp to read a newspaper, illustrating typical usage.
Penyelenggaraan
- Membersihkan Lensa: Use a soft, lint-free cloth specifically designed for optical lenses to gently wipe the magnifying glass. Do not use abrasive cleaners or harsh chemicals, as these can damage the lens coating.
- Membersihkan Lamp Badan: Lap lamp's exterior with a soft, damp kain. Elakkan menggunakan kelembapan berlebihan atau agen pembersih yang keras.
- Storan: Simpan lamp in a clean, dry environment. Always ensure the protective cap is on the lens when storing to maintain its clarity.
Menyelesaikan masalah
- Lamp Tidak Dihidupkan:
- Check if the power plug is securely inserted into the electrical outlet.
- Sahkan bahawa salur keluar kuasa berfungsi.
- Ensure the power switch on the lamp base is in the "On" position.
- Light Flickers or is Dim:
- Check the power connection for any loose contacts.
- If the issue persists, contact customer support. The LEDs have a long lifespan (approx. 25,000 hours) and are not user-replaceable.
- Magnified Image is Unclear:
- Adjust the distance between the magnifying lens and the object. The optimal focal distance is crucial for clear magnification.
- Ensure the lens is clean and free of dust or smudges. Refer to the "Maintenance" section for cleaning instructions.
Spesifikasi Teknikal
| Jenama | Fizik |
| Model | FL-30LED |
| warna | putih |
| Pembesaran | 2.25x (5 Diopter) |
| Diameter Kanta | 10.2 cm (4 inci) |
| Sumber Cahaya | 30 LED SMD |
| Penggunaan Kuasa | 6W |
| Jangka Hayat LED | Lebih kurang 25,000 jam |
| Panjang Kabel | 2.5 meter |
| Bekalan Kuasa | 220-240V |
| Ketinggian | 33 sm |
| Berat badan | 1.58 kg |
| Dimensi Pakej | 28 x 22 x 21.8 cm |
| Bahan Lensa | kaca |

Image: Energy label for the Fysic FL-30LED lamp. For more details, visit eprel.ec.europa.eu/qr/765452.
Waranti dan Sokongan
For warranty information, technical support, or service inquiries, please refer to the contact details provided with your purchase documentation or visit the official Fysic webtapak. Simpan bukti pembelian anda untuk tuntutan waranti.