PowerWalker 10122182

PowerWalker VFI 3000 AT UPS User Manual

Model: 10122182

pengenalan

The PowerWalker VFI AT series is an online Uninterruptible Power Supply (UPS) system designed to provide reliable power protection for critical electronic devices. This manual provides essential information for the safe and efficient operation of your PowerWalker VFI 3000 AT UPS, model 10122182.

Arahan Keselamatan Penting

Sila baca dan ikuti semua arahan dengan teliti sebelum memasang, mengendalikan atau menservis UPS. Simpan manual ini untuk rujukan pada masa hadapan.

Kandungan Pakej

Verify that all items listed below are included in your package. If any items are missing or damaged, contact your dealer.

Produk Selesaiview

Panel Depan

Depan view of PowerWalker VFI 3000 AT UPS with display and control buttons.

Rajah 1: Depan view of the PowerWalker VFI 3000 AT UPS. This image displays the main chassis, ventilation grilles, and the front control panel with its LCD screen and buttons.

Close-up of PowerWalker VFI 3000 AT UPS front panel showing LCD and buttons.

Rajah 2: Terperinci view of the UPS front panel. The LCD screen shows input/output voltage and load status. Below the screen are control buttons: ON, OFF, ENTER, and ESC, used for navigating menus and controlling the unit.

The front panel features an LCD display that provides real-time information about the UPS status, including input/output voltage, battery level, and load capacity. Control buttons allow for navigation through the display menus and basic operation of the unit.

Panel Belakang

belakang view of PowerWalker VFI 3000 AT UPS showing power outlets, communication ports, and fans.

Rajah 3: belakang view of the PowerWalker VFI 3000 AT UPS. This panel includes multiple Type F earthing contact outlets for connecting protected devices, cooling fans, a main power input, and communication ports (USB, RS-232, and an optional slot for network card).

The rear panel provides the necessary connections for input power, output to protected devices, and communication interfaces. It includes four Type F earthing contact outlets, a terminal output, USB and RS-232 communication ports, and slots for optional accessories like network cards.

Arahan Persediaan

1. penempatan

2. Menyambung kepada Kuasa

  1. Connect the provided power input cable to the UPS input receptacle on the rear panel.
  2. Plug the other end of the power input cable into a grounded wall outlet.
  3. Biarkan UPS dicas sekurang-kurangnya 8 jam sebelum penggunaan awal untuk memastikan prestasi bateri yang optimum.

3. Menghubungkan Peranti

  1. Plug your critical devices (e.g., computers, servers, network equipment) into the Type F output receptacles on the rear panel of the UPS.
  2. Ensure that the total load connected to the UPS does not exceed its rated capacity (2700W for this model).
  3. For devices requiring terminal output, connect them according to electrical safety standards.

4. Permulaan Awal

  1. After connecting the UPS to AC power and allowing initial charging, press and hold the ON button on the front panel for approximately 2 seconds.
  2. The UPS will perform a self-test, and the LCD display will illuminate, indicating operational status.
  3. The UPS is now providing protected power to the connected devices.

Mengendalikan UPS

Menghidupkan/Mematikan

Memahami Paparan LCD

The LCD display provides critical information about the UPS status. Use the MASUK dan ESC buttons to navigate through different display screens, which may include:

Operasi Sandaran Bateri

Sekiranya berlaku kuasa outage atau volum ketaratage fluctuation, the UPS will automatically switch to battery power to provide continuous power to connected devices. An audible alarm may sound, and the LCD will indicate "Battery Mode." The duration of battery backup depends on the load connected and the battery charge level.

Perisian Komunikasi

For advanced monitoring and management, install the provided communication software on a computer connected to the UPS via the USB or RS-232 port. This software allows for scheduled shutdowns, remote monitoring, and detailed event logging.

Penyelenggaraan

Penjagaan Bateri

Pembersihan

Penyimpanan

Menyelesaikan masalah

Refer to the table below for common issues and their solutions. If the problem persists, contact technical support.

MasalahKemungkinan PuncaPenyelesaian
UPS tidak dihidupkan.No AC input power.
Cas bateri rendah.
Periksa sambungan kord kuasa dan salur keluar dinding.
Allow UPS to charge for several hours.
UPS berbunyi bip berterusan dalam mod biasa.Keadaan beban berlebihan.
Kesalahan dalaman.
Reduce the load by unplugging non-essential devices.
Hubungi sokongan teknikal.
Masa sandaran yang singkat.Bateri tidak dicas sepenuhnya.
Batteries reaching end of life.
Beban berlebihan.
Allow UPS to charge for 8+ hours.
Contact service for battery replacement.
Kurangkan beban bersambung.
UPS is noisy.Normal fan operation (especially under load).
Penghalang kipas.
This is normal for online UPS units. Ensure proper ventilation.
Check for and clear any obstructions around fans.

Spesifikasi

CiriPerincian
Model10122182
Kapasiti3000 VA / 2700 W
Input Voltage300 Volts (nominal)
Keluaran Voltage300 Volts (nominal)
Jenis BateriAsid Plumbum, AGM
Bateri Termasukya
Saluran Keluaran4x Type F Earthing Contact, Terminal Output
Faktor BentukMenara
Dimensi (L x W x H)41.6 x 19.6 x 34.2 cm
Berat badan21 kg
bahanplastik
Amppemadam9 Amps

Waranti dan Sokongan

The PowerWalker VFI 3000 AT UPS is covered by a manufacturer's warranty. For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official PowerWalker webtapak.

For technical support, service inquiries, or to report any issues, please contact your local dealer or PowerWalker customer service. Have your model number (10122182) and purchase information ready when contacting support.