1. Pengenalan
The Apera Instruments Value Series EC850 Portable Conductivity Meter Kit is engineered for precise conductivity and TDS measurements in various field applications. Its robust design and practical features ensure reliable performance and ease of use for professionals.
2. Produk Lebihview
2.1 Ciri-ciri Utama
- Reliable conductivity/TDS measurements for quick and easy analysis.
- IP57 rugged structure, ideal for field use, with a foldable stand for benchtop operation.
- Automatic 1- to 3-point calibration, with included calibration solutions.
- Built-in temperature sensor for automatic temperature compensation (ATC).
- Self-diagnosis function to ensure proper calibration and assist with common issues.
2.2 Apa yang ada di dalam Kotak
- Apera Instruments EC850 Portable Conductivity Meter Kit
2.3 Komponen Produk

Figure 1: The EC850 meter with its conductivity probe, displaying a measurement of 1413 µS at 25.0°C. The meter is waterproof and features clear buttons for calibration, mode, setup, and power.

Figure 2: The EC850 meter shown with its integrated kickstand extended, allowing for convenient benchtop use. The display shows a reading of 1413 µS and 25.0°C.

Rajah 3: Jarak dekat view of the conductivity probe's connector, designed for secure attachment to the EC850 meter.

Figure 4: The complete EC850 Portable Conductivity Meter Kit neatly organized within its durable carrying case, including the meter, probe, and calibration solutions.

Rajah 5: Terperinci view of the conductivity probe tip, showing the electrodes responsible for accurate measurements.
3. Persediaan
3.1 Pemeriksaan Awal
Upon receiving your EC850 kit, carefully inspect all components for any signs of damage during transit. Ensure all listed items in "What's in the Box" are present.
3.2 Pemasangan Bateri
Locate the battery compartment on the back of the meter. Insert the required batteries (typically AA or AAA, refer to the meter's battery compartment for specific type and polarity) ensuring correct orientation. Close the compartment securely.
3.3 Sambungan Probe
Connect the conductivity probe to the meter's input port. Ensure the connection is firm and secure to prevent measurement inaccuracies.
3.4 Penentukuran Awal
For optimal accuracy, perform an initial calibration. The EC850 supports 1- to 3-point automatic calibration. Refer to the included quick start guide for detailed steps on using the provided calibration solutions.
4. Arahan Operasi
4.1 Pengukuran Asas
- Hidupkan meter dengan menekan butang kuasa.
- Rinse the probe thoroughly with distilled or deionized water before each measurement.
- Rendam kuar ke dalam sample solution, ensuring the sensor area is fully submerged.
- Allow the reading to stabilize on the display. The meter will show conductivity/TDS and temperature.
- Record the measurement.
- Rinse the probe again after use.
4.2 Understanding Display Readings
The EC850 display shows the primary measurement (Conductivity in µS/cm or mS/cm, or TDS in ppm) and the temperature in °C. The meter automatically compensates for temperature variations (ATC) to provide accurate readings.
4.3 Self-Diagnosis
The meter features a self-diagnosis function that can alert you to common issues such as calibration errors or probe problems. Follow the on-screen prompts or consult the troubleshooting section for guidance.
5. Penyelenggaraan
5.1 Membersihkan Probe
Regularly clean the conductivity probe to prevent buildup that can affect accuracy. Rinse the probe with distilled water after each use. For stubborn deposits, refer to the detailed cleaning instructions in the full manual or Apera Instruments' support resources.
5.2 Penyimpanan
When not in use, store the probe in its protective cap with a small amount of storage solution (or appropriate calibration solution if storage solution is unavailable). Store the meter and probe in a cool, dry place, preferably in its original carrying case.
5.3 Penggantian Bateri
Replace batteries when the low battery indicator appears on the display. Ensure the meter is turned off before opening the battery compartment. Dispose of old batteries responsibly.
6. Penyelesaian masalah
If you encounter issues with your EC850 meter, consult the following common problems and solutions:
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Bacaan Tidak Tepat | Dirty probe, expired calibration, incorrect calibration. | Clean the probe, recalibrate the meter with fresh solutions, ensure correct calibration procedure. |
| Meter tidak menyala | Dead batteries, incorrect battery installation. | Replace batteries, check battery polarity. |
| Bacaan Tidak Menentu | Air bubbles on probe, damaged probe, electrical interference. | Gently tap the probe to dislodge bubbles, inspect probe for damage, move away from strong electrical fields. |
For more complex issues or persistent problems, please contact Apera Instruments customer support.
7. Spesifikasi
| Atribut | Perincian |
|---|---|
| Dimensi Produk | 13.78 x 10.63 x 3.15 inci; 2.6 paun |
| Nombor Model Item | AI5512 |
| Pengeluar | Alat Apera |
| ASIN | B083RC3441 |
| Pertama Tersedia | 11 Januari 2020 |
| Peringkat Perlindungan Ingress (IP). | IP57 (kalis air) |
| Penentukuran | Automatic 1- to 3-point |
| Pampasan Suhu | Automatic (ATC) |
8. Waranti dan Sokongan
Apera Instruments products are backed by a manufacturer's warranty. For detailed information regarding your product's warranty period, terms, and conditions, please visit the official Apera Instruments webtapak atau hubungi sokongan pelanggan mereka secara langsung.
For technical assistance, troubleshooting, or to purchase replacement parts and accessories, please reach out to Apera Instruments customer service. Contact information can typically be found on their official webtapak atau dalam pembungkusan produk.
Pengeluar: Alat Apera
Webtapak: www.aperainst.com