The ATO Load Cell Junction Box is designed to sum signals from multiple load cells, typically used in weighing systems such as electronic truck scales and hopper weighers. This device features a robust aluminum alloy casing, providing excellent anti-interference capabilities and an IP67 protection rating for waterproof and dustproof performance. It is equipped with 4 inlets for individual load cells and 1 outlet for the summed signal, making it easy to assemble and debug.

ATO Load Cell Junction Box, top view

Figure 1: ATO Load Cell Junction Box (Top View)

This image shows the exterior of the ATO Load Cell Junction Box, a black rectangular aluminum alloy casing with cable glands on the sides for secure cable entry and exit.

2. Ciri-ciri Utama

3. Kandungan Pakej

Please verify that all items are present and undamaged upon opening the package.

4. Persediaan dan Pemasangan

Proper installation is crucial for the accurate and reliable operation of the load cell system. Ensure power is disconnected from all components before beginning installation.

4.1 Pemasangan Fizikal

Load cell junction box dimensions

Figure 2: Load Cell Junction Box Dimensions

This diagram provides the physical dimensions of the junction box in millimeters, including length, width, and height, along with the spacing of mounting holes.

4.2 Pendawaian Elektrik

The junction box is designed for 4 load cell inputs and 1 summed output. Refer to the wiring diagram below for correct connections.

Load cell junction box wiring diagram

Figure 3: Load Cell Junction Box Wiring Diagram

This diagram illustrates the internal circuit board with terminal blocks, showing connections for four load cells (LC1, LC2, LC3, LC4) to the left side and the single output connection to the right. Wire colors (Black, White, Green, Red) are indicated for both input and output, corresponding to common load cell wiring standards (e.g., Black for -EXE, White for -SIG, Green for +SIG, Red for +EXE, and SHILD for shield).

Dalaman view of ATO Load Cell Junction Box

Gambar 4: Dalaman View daripada Junction Box

This image displays the open junction box, revealing the internal circuit board with terminal blocks for connecting load cells and the output, along with potentiometers for individual channel adjustments.

5. Arahan Operasi

The junction box functions as a passive summing device for load cell signals. Its primary operation involves signal combination and balance adjustment.

5.1 Signal Summing

Once all load cells are correctly wired, the junction box combines their individual electrical signals into a single output signal. This combined signal represents the total force or weight measured by all connected load cells.

5.2 Balance Adjustment (Debugging)

Each load cell input (LC1, LC2, LC3, LC4) on the PCB has an associated potentiometer (small blue adjustable resistors). These potentiometers are used to balance the output of each individual load cell, compensating for slight variations in their sensitivity or initial zero offset. This ensures that the summed signal is accurate and that the system provides consistent readings across the entire weighing platform.

6. Penyelenggaraan

The ATO Load Cell Junction Box is designed for low maintenance due to its robust construction and IP67 rating. However, periodic checks are recommended to ensure optimal performance.

7. Penyelesaian masalah

If you encounter issues with your load cell system, consider the following troubleshooting steps related to the junction box:

MasalahKemungkinan PuncaPenyelesaian
Inaccurate or Unstable Readings
  • Load cells are not balanced.
  • Sambungan pendawaian longgar atau salah.
  • Damaged load cell or cable.
  • External electrical interference.
  • Perform balance adjustment using the potentiometers (refer to Section 5.2).
  • Periksa semua sambungan pendawaian untuk memastikan ketat dan kekutuban yang betul.
  • Test individual load cells to identify any faulty ones.
  • Ensure proper grounding and shielding of cables.
Tiada Keluaran Isyarat
  • Incorrect wiring of output cable.
  • All load cells are faulty or disconnected.
  • Problem with the weighing indicator/transmitter.
  • Verify output wiring against the diagram (Figure 3).
  • Check continuity of load cell cables and functionality of each load cell.
  • Test the weighing indicator/transmitter independently.
Water or Dust Ingress
  • Cable glands not tightened properly.
  • Damaged or missing rubber gaskets.
  • Cracked casing.
  • Ensure all cable glands are securely tightened.
  • Inspect and replace any damaged gaskets.
  • Jika casing is cracked, the unit may need replacement.

8. Spesifikasi

AtributPerincian
Nombor ModelATO-LCJBX-JXH-S4
JenamaATO
bahanAloi Aluminium
warnaHitam
GayaPadat
Jenis SelesaiBersalut Serbuk
Saluran masuk4 (for load cells)
Outlet1 (summed signal)
Ketepatan±0.1%FS
Kelas PerlindunganIP67 (kalis air dan habuk)
Dimensi Pakej10.51 x 5.16 x 1.97 inci
Berat Barang1.59 paun

9. Waranti dan Sokongan