Brifit 650728980513

Brifit Digital Refrigerator Freezer Thermometer

Manual Arahan - Model 650728980513

1. Pengenalan

Thank you for choosing the Brifit Digital Refrigerator Freezer Thermometer. This device is designed to monitor temperatures in your refrigerator, freezer, or other indoor/outdoor environments using two wireless sensors. It features a large LCD display, temperature alarm functions, and records maximum/minimum temperatures to help ensure optimal storage conditions.

Brifit Digital Refrigerator Freezer Thermometer main unit and two wireless sensors

Image 1.1: Main unit and two wireless sensors of the Brifit Digital Thermometer.

2. Kandungan Pakej

  • 1 x Main Display Unit
  • 2 x Sensor Alat Kawalan Jauh Tanpa Wayar
  • 1 x Manual Pengguna

3. Produk Lebihview

The main unit features a large LCD screen displaying indoor temperature, two sensor temperatures, and MAX/MIN records. The remote sensors transmit temperature data wirelessly to the main unit.

Terperinci view of the Brifit thermometer's LCD display and buttons

Imej 3.1: Terperinci view of the main unit's LCD display and function buttons.

Main Unit Display and Buttons:

  • Paparan Suhu Dalaman: Shows the temperature at the main unit's location.
  • Sensor 1/2 Temperature Display: Shows temperatures from the respective wireless sensors.
  • Rekod MAKSIMUM/MINIT: Displays the highest and lowest temperatures recorded for each channel over the last 24 hours.
  • Penunjuk Penggera: Visual cues for active temperature alarms.
  • +/°C/°F Button: Adjusts values or switches between Celsius and Fahrenheit.
  • - Butang: Melaraskan nilai.
  • Butang CLEAR: Clears MAX/MIN data.
  • ALARM SENSOR1/SENSOR2/INDOOR Buttons: Activates/deactivates alarms for specific channels.

4. Persediaan

4.1 Pemasangan Bateri

Batteries are not included. You will need 2 x AAA batteries for the main unit and 2 x AA batteries for each wireless sensor (total 4 x AA batteries for two sensors).

  1. Open the battery compartment on the back of the main unit and insert 2 AAA batteries, observing polarity (+/-).
  2. Open the battery compartment on the back of each wireless sensor and insert 2 AA batteries into each, observing polarity (+/-).
  3. Tutup semua petak bateri dengan ketat.
Diagram showing battery installation for the main unit and wireless sensors

Image 4.1: Battery installation for the main unit (2x AAA) and each sensor (2x AA).

4.2 Sensor and Main Unit Placement

The main unit and sensors offer multiple installation options:

  • Unit Utama: Can be placed on a tabletop using its integrated stand, hung on a wall via the hanging hole, or attached to a metallic surface (e.g., refrigerator door) using its built-in magnets.
  • Sensor Tanpa Wayar: Each sensor has a clip and a hanging hole, allowing them to be clipped onto a shelf or hung. Place sensors in the refrigerator, freezer, or any other area where temperature monitoring is desired.
Diagram showing various placement options for the Brifit thermometer main unit and sensors

Image 4.2: Placement options for the main unit (standing, hanging, magnetic) and sensors (hanging, lying flat, clamping).

Ensure the sensors are within the transmission range of 100 meters (open area) from the main unit. Walls and other obstructions may reduce this range.

Illustration of wireless signal transmission range between sensor and main unit

Image 4.3: Wireless transmission range illustration, showing sensors in a fridge and outdoors.

5. Operasi

5.1 Hidupkan/Mati Kuasa

The device powers on automatically once batteries are inserted. There is no dedicated power button. To turn off, remove the batteries.

5.2 Menukar Unit Suhu (°C/°F)

Tekan ke +/°C/°F button on the main unit to toggle between Celsius (°C) and Fahrenheit (°F) display.

5.3 Menetapkan Penggera Suhu

The thermometer allows you to set maximum and minimum temperature alarms for each channel (Indoor, Sensor 1, Sensor 2).

  1. Tekan ke ALARM SENSOR1, ALARM SENSOR2, atau ALARM INDOOR button to select the channel for which you want to set an alarm.
  2. Press and hold the selected ALARM button until the MAX alarm value starts flashing. Use the + or - buttons to adjust the desired maximum temperature.
  3. Press the ALARM button again to switch to the MIN alarm value. Use the + or - buttons to adjust the desired minimum temperature.
  4. Press the ALARM button a third time to confirm and exit the alarm setting mode.
  5. An alarm icon will appear on the display for the activated channel. When the temperature exceeds the set MAX or falls below the set MIN, an audible alarm will sound, and the corresponding temperature will flash.
Illustration of the audible alarm feature and alarm setting on the Brifit thermometer

Image 5.1: Audible alarm feature and setting MAX/MIN alarm values.

5.4 Viewing and Clearing MAX/MIN Records

The device automatically records the highest (MAX) and lowest (MIN) temperatures over the last 24 hours for each channel.

  • The MAX/MIN values are continuously displayed on the screen.
  • To clear the recorded MAX/MIN values and start a new recording cycle, press the JELAS button. The display will show the current temperature as the new MAX/MIN until new extremes are reached.

6. Penyelenggaraan

6.1 Pembersihan

Lap unit utama dan sensor dengan kain lembut,amp kain. Jangan gunakan pembersih yang kasar atau rendam peranti di dalam air.

6.2 Penggantian Bateri

Replace batteries when the low battery indicator appears on the display. Follow the battery installation steps in Section 4.1.

7. Penyelesaian masalah

  • No Temperature Display / Inaccurate Readings:
    • Periksa sama ada bateri dipasang dengan betul dan tidak habis. Gantikan jika perlu.
    • Ensure sensors are within the transmission range of the main unit. Reduce distance or remove obstructions.
    • Re-sync sensors by removing and reinserting batteries in both the main unit and sensors.
  • Penggera Tidak Berbunyi:
    • Verify that the alarm function is activated for the desired channel (alarm icon visible).
    • Check if the set MAX/MIN alarm values are appropriate for the monitored temperature range.

8. Spesifikasi

Ciri Spesifikasi
Julat Suhu Dalaman -10 ℃ ~ 60 ℃ (14 ℉ ~ 140 ℉)
Outdoor/Sensor Temperature Range -40 ℃ ~ 60 ℃ (-40 ℉ ~ 140 ℉)
Ketepatan Suhu ± 1 °C
Julat Penghantaran Sehingga 100 meter (328 kaki) di kawasan terbuka
Kuasa Unit Utama 2 x Bateri AAA (tidak termasuk)
Kuasa Sensor 2 x AA Batteries per sensor (not included)
Jenis Paparan LCD
Teknologi Ketersambungan Tanpa wayar
Dimensi Produk (Unit Utama) 9.5 x 6.5 x 11 cm
Nombor Model 650728980513
Dimensions of the Brifit thermometer main unit and wireless sensor

Image 8.1: Product dimensions for the main unit and a wireless sensor.