Nohken OLV-2P
Nohken OLV-2P Liquid Level Sensor User Manual
Model: OLV-2P
1. Pengenalan
This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of the Nohken OLV-2P Liquid Level Sensor. Please read this manual thoroughly before using the product to ensure safe and efficient operation. Keep this manual for future reference.
2. Produk Lebihview
The Nohken OLV-2P is a reliable liquid level sensor designed for various applications. It operates using a Reed contact installed within its axis and a permanent magnet located in the float. The sensor activates its contact when the liquid level rises or falls, and its switching state (normally open or normally closed) is determined by the direction of installation.
Key features of the OLV-2P sensor include:
- Good resistance to oils and acids, making it suitable for a wide range of media including acids, oils, gasoline, and water.
- High switching power, capable of handling up to 0.5 A and up to 10 million switching cycles.
- Can be switched without an intermediate relay.
- Maximum temperature load specified at 90 °C.
Typical areas of application include small containers of all types, coffee machines, aquariums, control of small filters, pumps, and photocopiers.
3. Maklumat Keselamatan
Sentiasa patuhi langkah keselamatan berikut untuk mengelakkan kecederaan atau kerosakan pada produk:
- Pastikan kuasa diputuskan sebelum pemasangan, penyelenggaraan atau penyelesaian masalah.
- Do not exceed the specified maximum voltage (300 Volts) or current (0.5 A).
- Do not expose the sensor to temperatures exceeding 90 °C.
- Verify compatibility with the liquid media before installation.
- Installation should be performed by qualified personnel if electrical wiring is involved.
4. Persediaan dan Pemasangan
The Nohken OLV-2P sensor is designed for straightforward installation. The key aspect of installation is determining the desired switching state (normally open or normally closed) by the sensor's orientation.
4.1 Membuka kotak dan Pemeriksaan
Upon receiving your OLV-2P sensor, carefully open the packaging and inspect the unit for any signs of damage. Ensure all components are present.

Figure 1: The Nohken OLV-2P liquid level sensor, shown resting on its small product box.
4.2 Memasang Penderia
The sensor is typically mounted through a threaded opening in the wall or top of a container. The float should be positioned to move freely with the liquid level.

Rajah 2: Satu terperinci view of the sensor's threaded connection, indicating how it can be secured.

Figure 3: The sensor viewed from the side, illustrating the float's position relative to the main body.
4.3 Determining Switching State
The OLV-2P sensor's switching behavior (whether it acts as a normally open or normally closed contact) is determined by its installation orientation. Experiment with the sensor's position (e.g., float up or float down when liquid is present/absent) to achieve the desired switching logic for your application.

Figure 4: An overhead perspective of the sensor, highlighting the float and the electrical wiring.
4.4 Sambungan Elektrik
Connect the sensor's wires to your control circuit. Ensure the voltage and current ratings of your circuit are within the sensor's specifications (max 300V, 0.5A). The sensor can be directly integrated without an intermediate relay if the load is within its switching capacity.

Figure 5: The sensor with its wires laid out, ready for electrical connection.
5. Arahan Operasi
Once installed and connected, the Nohken OLV-2P sensor operates automatically. The float will rise or fall with the liquid level. As the float moves, the permanent magnet inside it will interact with the Reed contact within the sensor's axis, causing the contact to open or close. This change in contact state can then be used to trigger alarms, control pumps, or activate other devices in your system.
No user intervention is required during normal operation, provided the sensor is correctly installed and the liquid properties are within its specified limits.
6. Penyelenggaraan
The Nohken OLV-2P sensor is designed for low maintenance. However, periodic inspection and cleaning are recommended to ensure optimal performance and longevity.
6.1 Pembersihan
If the sensor is used in media that can leave residue, periodically remove the sensor and gently clean the float and stem with a soft cloth. For stubborn deposits, use a cleaning agent compatible with the sensor's materials and the liquid being monitored. Ensure the sensor is completely dry before reinstallation.
6.2 Pemeriksaan
Regularly inspect the sensor for any signs of physical damage, corrosion, or wear on the float or wiring. Check that the float moves freely along the stem. If any damage is observed, replace the sensor.
7. Penyelesaian masalah
If you experience issues with your Nohken OLV-2P sensor, consider the following common problems and solutions:
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Sensor not switching | Incorrect installation orientation (switching state) Float stuck due to debris/residue Pendawaian rosak atau komponen dalaman | Reverse sensor orientation to change NO/NC state Clean the float and stem Check wiring for continuity; replace sensor if damaged |
| Bacaan tidak konsisten | Turbulence in liquid Float partially obstructed Gangguan elektrik | Reduce turbulence if possible Ensure float moves freely Shield wiring or move away from interference sources |
| Sensor leaks | Pengedap yang tidak betul semasa pemasangan Perumahan retak | Re-install with proper sealant/gasket Gantikan sensor |
Jika masalah berterusan selepas mencuba penyelesaian ini, hubungi khidmat pelanggan.
8. Spesifikasi
| Atribut | Nilai |
|---|---|
| Pengeluar | Nohken |
| Nombor Model | OLV-2P |
| Dimensi Produk (L x W x H) | 12.7 x 5.08 x 5.08 cm |
| Berat badan | 27.22 gram |
| Voltage Peringkat | 300 Volt |
| Maksimum Semasa | 0.5 A |
| Max Temperature Load | 90 °C |
| Kuantiti Barang | 1 |
| Bateri Termasuk? | Tidak |
| Bateri Diperlukan? | Tidak |
9. Waranti dan Sokongan
Nohken provides a 1-year availability for spare parts for the OLV-2P sensor. For warranty claims, technical support, or inquiries regarding spare parts, please contact your retailer or the official Nohken support channels. Ensure you have your product model number (OLV-2P) and purchase details ready when contacting support.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.