Jectse Jectseh4tnewb30y-03
Jectse Timer Soft Starter Instruction Manual
Model: Jectseh4tnewb30y-03
1. Produk Lebihview
The Jectse Timer Soft Starter is a versatile delay relay motor starter designed for efficient motor start control. It features adjustable delay ranges and wide working voltage compatibility, making it suitable for various industrial and scientific applications.

Rajah 1: Depan view of the Jectse Timer Soft Starter, showing the control knobs and indicator lights.
2. Ciri-ciri Utama
- Adjustable Start Delay (T1): Range from 0.1 seconds to 10 minutes, set via knob.
- Adjustable Conversion Time (T2): Range from 0.1 seconds to 1 second, set via knob.
- Wide Working Voltage: Supports AC/DC 12V to 240V.
- Penunjuk LED: Clearly shows the working status of the relay.
- Reka bentuk padat: Super small size, only 18mm wide, designed for 35mm rail mounting.

Figure 2: The soft starter unit highlighting its compact size and adjustable settings.
3. Maklumat Keselamatan
Please read and understand all safety instructions before installing or operating this device. Failure to follow these instructions may result in electrical shock, fire, or serious injury.
- Pastikan bekalan elektrik diputuskan sebelum sebarang pemasangan atau pendawaian.
- Pemasangan hendaklah hanya dilakukan oleh kakitangan yang berkelayakan.
- Sahkan voltage and current ratings before connecting to a power source.
- Jangan dedahkan peranti kepada kelembapan atau suhu yang melampau.
- Pastikan pembumian yang betul di tempat yang diperlukan.
4. Kandungan Pakej
Pakej termasuk:
- 1 x Jectse Timer Soft Starter
5. Persediaan dan Pemasangan
The Jectse Timer Soft Starter is designed for 35mm DIN rail mounting. Follow these steps for proper installation:
- Ensure all power to the circuit is turned off at the main breaker.
- Mount the soft starter securely onto a standard 35mm DIN rail. The red clips on the side facilitate easy mounting and removal.
- Connect the power supply to terminals A1 and A2. The device supports AC/DC 12-240V.
- Connect the motor control wiring to the output terminals (15, 16, 18, 25, 26, 28) as per your application's wiring diagram. Refer to the diagram on the side of the unit for specific connections.
- Ensure all wiring connections are secure and meet the specified wiring capacity (1x2.5mm² or 2x 1.5mm²).
- Periksa semula semua sambungan sebelum memulihkan kuasa.

Rajah 3: Jarak dekat view of the wiring terminals and the integrated wiring diagram on the unit.

Rajah 4: Sisi view illustrating the red clips for DIN rail mounting.
6. Arahan Operasi
Once installed and powered, the Timer Soft Starter operates based on its configured delay settings.
- Setting Start Delay (T1): Use the knob labeled 'T1' to adjust the initial start delay from 0.1 seconds to 10 minutes. This delay determines how long the soft starter waits before initiating the motor start sequence.
- Setting Conversion Time (T2): Use the knob labeled 'T2' to set the conversion time from 0.1 seconds to 1 second. This time is crucial for the smooth transition during the motor's soft start phase.
- Penunjuk LED:
- A green LED indicates the power status (Un).
- A red LED indicates the relay's working status (R).
Video 1: Tamatview of the Jectse Timer Soft Starter, demonstrating its features and appearance.
7. Penyelenggaraan
The Jectse Timer Soft Starter is designed for long-term reliability with minimal maintenance. However, regular checks can ensure optimal performance:
- Periksa sambungan pendawaian secara berkala untuk kesesakan dan tanda-tanda haus atau kakisan.
- Pastikan unit bersih dan bebas daripada habuk dan serpihan. Gunakan kain kering dan lembut untuk pembersihan.
- Pastikan persekitaran operasi kekal dalam julat suhu dan kelembapan yang ditetapkan.
- Jangan cuba membuka atau membaiki unit sendiri. Rujuk kepada kakitangan perkhidmatan yang berkelayakan.
8. Penyelesaian masalah
If you encounter issues with your Timer Soft Starter, consider the following common problems and solutions:
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Unit not powering on (Green LED off) | No power supply; Incorrect wiring; Faulty unit. | Check power source; Verify A1/A2 wiring; Contact support if power is present and wired correctly. |
| Motor not starting after delay | Incorrect output wiring; Relay not activating; Motor issue. | Check output terminals (15, 16, 18, 25, 26, 28) connections; Observe red LED for relay status; Test motor independently. |
| Delay times are inaccurate | Knob settings incorrect; Environmental factors. | Re-adjust T1 and T2 knobs carefully; Ensure stable operating environment. |
If the problem persists after attempting these solutions, please contact Jectse customer support.
9. Spesifikasi
| Parameter | Nilai |
|---|---|
| taip | AC/DC 12V~240V |
| Rated Control Power Supply Voltage | AC/DC 12-240V (50/60Hz) |
| Penggunaan Kuasa | AC 0.7-3VA / DC 0.5-1.7W |
| Starting Delay (T1) | 0.1s - 10min |
| Conversion Delay (T2) | 0.1s - 1s |
| Menetapkan Ketepatan | 5% |
| Ulang Ketepatan | 0.2% |
| Keluaran | Two sets of conversion contacts 16A/AC250VAC |
| Minimum Switching Power | 500mW |
| Kehidupan Mekanikal | 1 x 10,000,000 kitaran |
| Electrical Life (Load) | 1,000,000 kitaran |
| Tetapkan Semula Masa | 200ms maksimum |
| Suhu Persekitaran Kerja | -20°C ~ 55°C |
| Suhu Penyimpanan dan Pengangkutan | -35°C ~ 75°C |
| Pemasangan | Pemasangan rel 35mm |
| Tahap Perlindungan | IP20 |
| Ketinggian Pemasangan | 2000 meter |
| Tahap Pencemaran | 2 |
| Kapasiti Pendawaian | 1x2.5mm² or 2x 1.5mm² |
| Dimensi | 90 x 18 x 64mm (3.5 x 0.7 x 2.5 inci) |
| Mematuhi Piawaian | GB14048.5.IEC/EN 60255-1 |
| Berat badan | Lebih kurang 96g (3.4oz) |
10. Waranti dan Sokongan
For warranty information or technical support, please contact Jectse customer service. Keep your purchase receipt for any warranty claims.
Pengeluar: Jectse
Nombor Model: Jectseh4tnewb30y-03
Tarikh Mula-mula Tersedia: 4 Mei 2019