PILZ PNOZ/X7/24VAC/DC
PILZ PNOZ/X7/24VAC/DC Safety Relay Instruction Manual
Model: PNOZ/X7/24VAC/DC | Part Number: 774059
1. Pengenalan
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the PILZ PNOZ/X7/24VAC/DC Safety Relay. Please read this manual thoroughly before using the device and keep it for future reference. Adherence to these instructions is crucial for ensuring proper function and preventing hazards.
The PILZ PNOZ/X7/24VAC/DC is a safety relay designed for monitoring E-stop buttons and safety gates. It features 1-channel wiring, 2 normally open (NO) contacts, and automatic reset functionality, operating on 24VAC/DC power.
2. Maklumat Keselamatan
AMARAN:
- Installation, commissioning, and maintenance must only be carried out by qualified electricians.
- Observe all national and international safety regulations and standards.
- Disconnect power before performing any work on the device.
- Do not bypass or disable safety functions.
- Ensure proper grounding and wiring according to the provided diagrams.
3. Produk Lebihview
The PILZ PNOZ/X7/24VAC/DC safety relay is a compact device designed for reliable safety circuit monitoring. It features clear terminal markings and status indicators for easy diagnostics.

Rajah 1: Depan view of the PILZ PNOZ/X7/24VAC/DC Safety Relay. This image displays the yellow and green housing, with clearly labeled terminals A1, 13, 23 at the top, and A2, 14, 24, Y1, Y2 at the bottom. Two LED indicators are visible: "POWER" and "CH.1/CH.2", indicating the operational status of the relay and its channels. The model name "pilz PNOZ X7" is printed on the front.
Ciri-ciri utama termasuk:
- Compact 22.5mm width.
- Fungsi set semula automatik.
- 2 Normally Open (NO) safety contacts.
- LED indicators for power and channel status.
- Suitable for E-stop monitoring and safety gate applications.
4. Persediaan dan Pemasangan
4.1 Pemasangan
The PNOZ/X7/24VAC/DC is designed for DIN rail mounting. Ensure adequate ventilation around the device.
- Mount the safety relay on a standard 35mm DIN rail in a control cabinet.
- Ensure secure fastening to prevent vibration.
4.2 Pendawaian
Refer to the wiring diagram below for correct connection. All connections must comply with local electrical codes.

Rajah 2: Close-up of the PILZ PNOZ/X7/24VAC/DC terminals. The top terminals are A1 (power input), 13, and 23 (safety outputs). The bottom terminals are A2 (power return), 14, 24 (safety outputs), and Y1, Y2 (feedback loop/reset). This view highlights the screw terminals for electrical connections.
- Power Supply (24VAC/DC): Connect the positive supply to terminal A1 and the negative/neutral to terminal A2.
- Input Circuit (E-Stop/Safety Gate): Connect the safety device (e.g., E-stop button) across terminals Y1 and Y2. For 1-channel wiring, ensure the circuit is closed when the safety device is active.
- Kenalan Output: Terminals 13-14 and 23-24 are normally open (NO) safety contacts. Connect these to the control circuit of the machinery to be controlled.
- Gelung Maklum Balas: For automatic reset, the feedback loop (Y1-Y2) must be closed.
PENTING:
Always verify wiring against the specific application requirements and the detailed wiring diagrams provided in the full product documentation from PILZ.
5. Arahan Operasi
The PNOZ/X7/24VAC/DC operates with an automatic reset function. Once the safety circuit is closed and the input conditions are met, the output contacts will close automatically.
5.1 Naik Kuasa
- Pastikan semua pendawaian betul dan selamat.
- Apply 24VAC/DC power to terminals A1 and A2.
- The "POWER" LED indicator will illuminate.
5.2 Operasi Biasa
- When the safety input (e.g., E-stop released, safety gate closed) is active, the "CH.1/CH.2" LED will illuminate.
- The safety output contacts (13-14, 23-24) will close, allowing the machine to operate.
5.3 Safety Function Activation
- If the safety input is interrupted (e.g., E-stop pressed, safety gate opened), the "CH.1/CH.2" LED will extinguish.
- The safety output contacts (13-14, 23-24) will open immediately, bringing the machine to a safe stop.
5.4 Automatic Reset
Once the safety input condition is restored (e.g., E-stop released, safety gate closed), the PNOZ/X7/24VAC/DC will automatically reset, and the output contacts will close again, provided no faults are detected.
6. Penyelenggaraan
The PILZ PNOZ/X7/24VAC/DC safety relay is designed for minimal maintenance. Regular inspections are recommended to ensure continued safe operation.
6.1 Pemeriksaan Rutin
- Pemeriksaan Visual: Periodically check the device for any signs of damage, discoloration, or loose connections.
- Ujian Fungsi: Regularly test the entire safety circuit, including the E-stop buttons and safety gates, to ensure the safety relay correctly de-energizes the outputs.
- Penunjuk LED: Verify that the "POWER" and "CH.1/CH.2" LEDs illuminate and extinguish as expected during operation and safety function activation.
6.2 Pembersihan
If cleaning is necessary, disconnect power and use a soft, dry cloth. Do not use abrasive cleaners or solvents.
PERHATIAN:
Do not attempt to open or repair the device. Refer all servicing to authorized personnel.
7. Penyelesaian masalah
This section provides guidance for common issues. For complex problems, contact PILZ technical support.
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| "POWER" LED off | Tiada bekalan kuasa atau vol tidak betultage. | Check 24VAC/DC power connection to A1/A2. Verify voltage. |
| "CH.1/CH.2" LED off, outputs open, but safety input is closed | Fault in safety input circuit (Y1-Y2) or internal fault. | Check wiring of E-stop/safety gate. Ensure contacts are clean and functioning. If problem persists, contact support. |
| Outputs do not close after safety input is restored | Feedback loop issue or internal fault. | Verify Y1-Y2 connection. Ensure no short circuits or open circuits. |
8. Spesifikasi Teknikal
| Parameter | Nilai |
|---|---|
| Model | PNOZ/X7/24VAC/DC |
| Nombor Bahagian | 774059 |
| Bekalan Voltage | 24 VAC/DC |
| Kenalan Keselamatan | 2 TIDAK (Biasanya Terbuka) |
| Kenalan Bantu | tiada |
| Pendawaian | 1-saluran |
| Reset Fungsi | Automatik |
| Lebar | 22.5 mm |
| Mod Pengendalian | Automatik |
| Hubungi Penilaian Semasa | 2 Amps |
9. Waranti dan Sokongan
For warranty information, technical support, or service inquiries, please contact PILZ directly or your authorized PILZ distributor. Keep your product model and part number (PNOZ/X7/24VAC/DC, 774059) available when contacting support.
PILZ Contact Information:
- Refer to the official PILZ weblaman web untuk mendapatkan butiran hubungan terkini untuk rantau anda.
- Sumber dalam talian dan Soalan Lazim juga mungkin tersedia.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.