ASOKO UNO-LK

ASOKO UNO-LK Under Cabinet LED Light Instruction Manual

Model: UNO-LK (3-Pack, Daylight White 4500K)

1. Pengenalan

Thank you for choosing the ASOKO UNO-LK Under Cabinet LED Light system. This manual provides detailed instructions for the safe and efficient installation, operation, and maintenance of your new lighting product. Please read this manual thoroughly before use and retain it for future reference.

The ASOKO UNO-LK LED lights are designed to provide bright, dimmable, and linkable illumination for various indoor applications such as kitchen counters, shelves, workbenches, and cupboards. This 3-pack system features 4500K Daylight White light, offering clear and vibrant illumination.

2. Maklumat Keselamatan Penting

WARNING: To reduce the risk of fire, electric shock, or injury to persons, follow these instructions carefully.

  • Pastikan bekalan kuasa diputuskan sebelum pemasangan atau penyelenggaraan.
  • Produk ini direka bentuk untuk kegunaan dalaman sahaja. Jangan dedahkan kepada air atau kelembapan yang tinggi.
  • Do not attempt to modify or disassemble the product. Refer all servicing to qualified personnel.
  • Use only the provided power adapter. Using an incompatible adapter may damage the product and void the warranty.
  • Jauhkan daripada kanak-kanak dan haiwan peliharaan.
  • Pastikan pengudaraan yang betul di sekitar penyesuai kuasa semasa operasi.
  • The power adapter is ETL Listed, ensuring safety standards are met.

3. Kandungan Pakej

Sahkan bahawa semua komponen terdapat dalam pakej anda:

  • 3 x ASOKO UNO-LK LED Light Bars (12-inch)
  • 1 x Power Adapter (ETL Listed 24V)
  • 1 x Suis Dimmer Rotary
  • 2 x Interconnect Cables (1.6 ft each)
  • 2 x Connectors (0.78 inch each)
  • Aksesori Pemasangan:
    • Klip Magnetik
    • 3M Adhesive Stickers
    • Skru
ASOKO UNO-LK Under Cabinet LED Light 3-Pack components
Figure 1: All components included in the ASOKO UNO-LK 3-pack LED light system.
Interconnect cables and connectors for ASOKO LED lights
Figure 2: Close-up of interconnect cables and direct connectors for linking light bars.
Dimensions of interconnect and extended cables, and connectors
Figure 3: Detailed lengths of interconnect cables (1.6 ft), extended cables (3.2 ft), and connectors (0.78 inch).

4. Persediaan dan Pemasangan

The ASOKO UNO-LK LED lights offer three installation methods to suit various surfaces and preferences. Before installation, ensure the mounting surface is clean and dry.

4.1. Kaedah Pemasangan

Diagram showing three installation methods: adhesive stickers, magnets, and screws
Figure 4: Visual guide for the three available installation methods.
  1. Method 1: Adhesive Stickers (for smooth surfaces)

    Clean the desired mounting surface thoroughly. Peel the backing from the 3M adhesive stickers and apply them to the back of the light bar. Press firmly onto the clean surface for at least 30 seconds. Allow the adhesive to cure for 24 hours before applying full load or stress.

  2. Method 2: Magnetic Clips (for iron surfaces)

    If your mounting surface is magnetic (e.g., metal shelves), simply attach the magnetic clips to the light bars. The magnets will securely hold the light bars in place. This method allows for easy repositioning.

  3. Method 3: Screws (for rough or permanent surfaces)

    Position the light bar and mark the screw hole locations. Drill pilot holes if necessary. Secure the light bar using the provided screws. This method offers the most permanent and robust installation.

4.2. Connecting the Light Bars

The light bars can be linked together using either the direct connectors or the interconnect cables.

  • Sambungan Terus: For seamless, end-to-end lighting, use the small direct connectors to join two light bars.
  • Sambungan Kabel: For spacing between light bars or routing around corners, use the 1.6 ft interconnect cables. Extended cables (3.2 ft) are also available for longer distances.

Connect the rotary dimmer switch to the first light bar in your series, and then connect the power adapter to the dimmer switch. Plug the power adapter into a standard electrical outlet.

ETL Listed 24V Power Adapter
Figure 5: The ETL Listed 24V power adapter, ensuring safety and reliability.

5. Arahan Operasi

5.1. Power On/Off and Dimming

The included rotary dimmer switch controls the power and brightness of the connected LED lights.

  • Hidupkan/Mati Kuasa: Press the central button on the rotary switch to turn the lights on or off.
  • Peredupan: Rotate the knob on the switch to adjust the brightness from 0% to 100% (stepless dimming).
  • Fungsi Memori: The lights will remember the last brightness setting used when powered off and will return to that level when powered back on.
Dimmable switch controlling light brightness from 10% to 100%
Figure 6: The rotary dimmer switch allows for stepless brightness adjustment.
Visual representation of 100%, 50%, and 10% brightness levels controlled by the dimmer switch
Figure 7: Illustrates the range of dimming capabilities from 10% to 100% brightness.

5.2. Smart Plug Compatibility

The ASOKO UNO-LK LED lights are compatible with smart plugs (not included). When used with a smart plug, the lights will retain their last brightness setting and can be controlled via the smart plug's app or voice commands (e.g., Alexa, Google Assistant).

ASOKO LED lights connected to a smart plug and controlled via voice command with Alexa
Figure 8: Demonstrates compatibility with smart plugs for scheduled operation and voice control.

6. Penyelenggaraan

  • Pembersihan: Disconnect power before cleaning. Wipe the light bars with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Pemeriksaan: Periodically check cables and connections for any signs of damage. If damage is found, discontinue use and contact customer support.
  • Sumber cahaya LED tidak boleh diganti.

7. Penyelesaian masalah

MasalahKemungkinan PuncaPenyelesaian
Lampu tidak menyala.
  • Tiada kuasa ke saluran keluar.
  • Sambungan longgar.
  • Dimmer switch is off.
  • Periksa salur keluar kuasa dengan peranti lain.
  • Ensure all cables and connectors are securely plugged in.
  • Press the central button on the dimmer switch to turn on.
Lampu berkelip-kelip atau malap.
  • Sambungan longgar.
  • Dimmer setting is too low.
  • Defective component (rare).
  • Check all connections, especially between light bars and the dimmer.
  • Adjust the dimmer knob to increase brightness.
  • Jika masalah berterusan, hubungi sokongan pelanggan.
Lights do not respond to smart plug.
  • Smart plug not configured correctly.
  • Dimmer switch is off or set to minimum brightness.
  • Refer to your smart plug's instruction manual for setup.
  • Ensure the dimmer switch is turned on and set to a desired brightness level before using the smart plug.

8. Spesifikasi

JenamaASOKO
Nama ModelUNO-LK
Nombor BahagianYQ-CGD-3C
Suhu Warna4500K Siang Putih
Kecerahan1299 Lumens (for 3-pack)
Wattage12 Watts (per light bar)
Voltage24 Volt
Dimensi Produk12"L x 0.23"W x 0.63"H (per light bar)
bahanAluminum, Plastic, Polycarbonate
Ciri KhasDimmable, Linkable, Memory Function
Sumber KuasaCorded Electric (ETL Listed 24V Plug)
Penggunaan Dalaman/LuarDalaman Sahaja
Tahap Ketahanan AirBukan Tahan Air
Dimensions of the ASOKO 12-inch LED light bar
Figure 9: Detailed dimensions of the 12-inch LED light bar.

9. Waranti dan Sokongan

ASOKO provides a 2-year warranty for this product. If you encounter any issues with your ASOKO UNO-LK LED lights within this period, please contact our customer support for assistance.

For support, please refer to the contact information provided with your purchase or visit the official ASOKO webtapak.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.