Apera Instruments AI521

Apera Instruments AI521 PH800 Laboratory Benchtop pH Meter Kit Instruction Manual

Model: AI521 PH800

1. Produk Lebihview

The Apera Instruments PH800 Benchtop pH Meter is engineered for precise and reliable pH measurements in various water solutions, suitable for scientific research and quality control applications. This kit includes Apera’s PC-body 201T-F pH/Temperature Electrode, enabling quick and accurate pH readings with automatic temperature compensation.

Ciri-ciri Utama:

  • Quick and easy 1 to 3 points automatic calibration with a calibration guide, automatically recognizing 5 types of pH standards (7.00, 4.00, 10.01, 12.45, 1.68).
  • High-quality 201T-F pH/temperature combination electrode ensures stable and accurate measurements for general water solutions.
  • GLP data management with 500 groups of data storage and USB data output.
  • Electrode slope display between calibrations to monitor the health and performance of your pH electrode.
  • Large backlit LCD displays pH and temperature simultaneously, along with icons for stable readings and completed calibrations.
  • ORP (Redox) measurement mode available with an optional ORP electrode (sold separately).
  • IP54 splash-proof design for enhanced durability.

2. Kandungan Pakej

The Apera Instruments PH800 Benchtop pH Meter Kit includes the following components:

  • PH800 Meter pH Atas Bangku
  • 201T-F pH/Temperature Electrode
  • Flexible Electrode Arm and Holder
  • Kabel USB
  • PC-Link Software Flash Drive (for Windows-based systems only)
  • DC9V (120V) Power Adapter
  • Calibration Solutions: 3 bottles (7.00, 4.00, 10.01, 50ml each)

3. Persediaan Awal

Follow these steps to set up your PH800 Benchtop pH Meter for first use:

  1. Buka Pembungkusan Komponen: Carefully remove all items from the packaging and inspect for any damage.
  2. Assemble Electrode Holder: Attach the flexible electrode arm and holder to the meter base. Ensure it is securely fastened to provide stable support for the electrode.
  3. Connect pH Electrode: Plug the BNC connector of the 201T-F pH/Temperature Electrode into the corresponding BNC port on the back of the meter. Connect the temperature probe into the TEMP port.
  4. Sambungkan Kuasa: Plug the DC9V power adapter into the meter's power input port and then into a standard electrical outlet.
  5. Sambungan USB Pilihan: If you plan to use the GLP data management features, connect the USB cable from the meter to your computer. Install the provided PC-Link software from the flash drive (Windows only).
Apera Instruments PH800 Benchtop pH Meter with electrode and beaker

Rajah 3.1: The Apera Instruments PH800 Benchtop pH Meter fully assembled with the electrode in a beaker, demonstrating a typical setup for measurement.

belakang view of Apera PH800 pH meter showing connection ports

Rajah 3.2: belakang view of the PH800 meter, highlighting the REF, pH/mV, TEMP, USB, and DC 9V connection ports for various probes and power.

Flexible electrode holder for Apera PH800 pH meter

Rajah 3.3: Close-up of the flexible electrode holder, designed for easy positioning and secure support of the pH electrode during operation.

4. Arahan Operasi

4.1. Menghidupkan/Mematikan

Tekan ke KUASA button (usually marked with a circle and vertical line icon) to turn the meter on or off. The large backlit LCD will illuminate upon startup.

Atas ke bawah view of Apera PH800 pH meter control panel

Rajah 4.1: Atas ke bawah view of the PH800 meter's control panel, showing the power button, mode/setup, enter, unit, calibration, and measurement buttons.

4.2. Penentukuran

Accurate calibration is crucial for reliable pH measurements. The PH800 supports 1 to 3 points automatic calibration.

  1. Prepare Buffer Solutions: Use fresh Apera calibration solutions (pH 7.00, 4.00, 10.01 are commonly included). Ensure the electrode and beakers are clean.
  2. Initiate Calibration: Tekan ke CAL button. The meter will enter calibration mode.
  3. First Point Calibration: Rinse the electrode with distilled water and immerse it in the pH 7.00 buffer solution. Stir gently and wait for the reading to stabilize. The meter will automatically recognize the buffer and confirm calibration.
  4. Second and Third Point Calibration (Optional): For higher accuracy, repeat the process with pH 4.00 and pH 10.01 buffer solutions. The meter will guide you through the process.
  5. Calibration Reminder: The meter features a calibration reminder function to ensure regular calibration for optimal performance.
  6. Keadaan Elektrod: The self-diagnosis function provides slope data between calibration points, allowing you to monitor the condition and performance of your pH electrode.

4.3. Pengukuran

After successful calibration, you can proceed with measurements.

  1. Rinse Electrode: Rinse the electrode thoroughly with distilled water before and after each measurement.
  2. Immerse Electrode: Immerse the electrode into the sample solution. Ensure the sensing part of the electrode is fully submerged.
  3. Tunggu Penstabilan: Allow the reading on the large backlit LCD to stabilize. A stable reading icon (often a smiley face) will appear when the measurement is ready. The display shows both pH and temperature simultaneously.
  4. Record Reading: Note down the pH and temperature values.
Apera PH800 pH meter large backlit screen displaying pH and temperature

Rajah 4.4: The large backlit LCD screen of the PH800 meter, clearly displaying pH and temperature readings, along with stabilization and calibration success icons.

4.4. Data Management (GLP & USB Output)

The PH800 meter offers advanced data management capabilities.

  • Penyimpanan Data: The meter can store up to 500 groups of measurement data, adhering to GLP (Good Laboratory Practice) standards.
  • USB Data Output: Connect the meter to a Windows-based computer via the USB cable to transfer stored data.
  • Perisian PC: Use the provided PC-Link software to view, analyze, and export data to spreadsheets for further analysis.
  • Auto-Timing Data Log: Utilize the auto-timing data log mode for professional measurements requiring timed data collection.
Apera PH800 pH meter connected to a laptop for USB data communication

Rajah 4.5: The PH800 meter connected to a laptop via USB, illustrating its GLP data management capabilities with auto/manual data logging and 500 sets of data storage.

5. Penyelenggaraan

Proper maintenance ensures the longevity and accuracy of your PH800 pH meter and electrode.

  • Pembersihan Elektrod: Regularly clean the pH electrode with distilled water. For stubborn residues, use a mild cleaning solution recommended for pH electrodes.
  • Penyimpanan Elektrod: When not in use, store the pH electrode in its protective cap filled with a suitable electrode storage solution (e.g., 3M KCl solution). Never store the electrode dry or in distilled water.
  • Pembersihan Meter: Wipe the meter's surface with a soft, damp cloth. Avoid using abrasive cleaners or solvents. The meter is IP54 splash-proof, but avoid direct water exposure.
  • Calibration Solutions: Keep calibration solutions sealed when not in use and replace them regularly to ensure accuracy.

6. Penyelesaian masalah

This section addresses common issues you might encounter with your PH800 pH meter.

  • Bacaan Tidak Tepat: Ensure the electrode is properly calibrated. Check the electrode's slope data in the self-diagnosis function; a low slope indicates an aging or faulty electrode. Clean the electrode thoroughly.
  • Respons Perlahan: This can be due to a dry or contaminated electrode. Rehydrate the electrode in storage solution or clean it.
  • Tiada Paparan/Kuasa: Check the power adapter connection and ensure the outlet is functional.
  • Calibration Errors: Ensure you are using fresh, correct buffer solutions. Follow the calibration steps precisely. The self-diagnosis function can help identify specific calibration issues.
  • Isu Pemindahan Data: Verify the USB cable connection and ensure the PC-Link software is correctly installed on a compatible Windows system.

For persistent issues, refer to the detailed troubleshooting guide in the full user manual or contact Apera Instruments customer support.

7. Spesifikasi Teknikal

SpesifikasiNilai
Nombor ModelAI521
Ketepatan pH0.01 pH ± 1 digit
Julat pH-2.00 hingga 19.99 pH
Resolusi pH0.1/0.01 pH
Pampasan Suhu0 - 100°C Automatic
Penyimpanan Data500 groups (GLP compliant)
KeluaranUSB
Jenis PenyambungBNC standard
Perlindungan IngressIP54 kalis percikan
Dimensi Produk9.5 x 8 x 4 inci
Berat Produk5.5 paun
PensijilanCE, RoHS, ISO 9001:2015

8. Waranti dan Sokongan

The Apera Instruments PH800 Benchtop pH Meter is manufactured under an ISO 9001:2015 certified quality system and is CE and RoHS certified, ensuring high standards of quality and safety.

For specific warranty information, technical assistance, or service inquiries, please contact Apera Instruments directly through their official website or authorized distributors. Please have your model number (AI521) and purchase date available when contacting support.

Dokumen Berkaitan - AI521

Praview 301Pt-C ORP Electrode User Manual
User manual for the Apera Instruments 301Pt-C ORP Electrode, covering installation, usage, maintenance, and warranty information.
Praview Manual Arahan Meter Atas Bangku MP511 pH/mV
Comprehensive instruction manual for the Apera Instruments MP511 pH/mV Benchtop Meter, covering setup, calibration, operation, maintenance, and troubleshooting.
Praview APERA INSTRUMENTS PC950 Benchtop pH/Conductivity Meter Instruction Manual
Comprehensive instruction manual for the APERA INSTRUMENTS PC950 Benchtop pH/Conductivity Meter, covering specifications, operation, calibration, maintenance, and troubleshooting for laboratory use.
Praview APERA Instruments pH 4.00 Buffer Solution Safety Data Sheet
Safety Data Sheet (SDS) for APERA Instruments pH 4.00 Buffer Solution, providing essential information on identification, hazards, first aid, handling, storage, and regulatory compliance.
Praview Apera Instruments 2301T-S Conductivity/Temp. Electrode User Manual
User manual for the Apera Instruments 2301T-S Conductivity/Temp. Electrode, detailing its specifications, installation, usage, maintenance, and limited warranty.
Praview Apera LabSen 213 Routine 3-in-1 pH Electrode User Manual
User manual for the Apera LabSen 213 Routine 3-in-1 pH Electrode, detailing its features, technical specifications, usage, maintenance, and warranty information for high-precision pH measurements.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.