BN-LINK BND-60/U110b-1

BN-LINK Digital Countdown Wall Timer Switch (Model BND-60/U110b-1) Instruction Manual

Model: BND-60/U110b-1 | Brand: BN-LINK

pengenalan

Thank you for choosing the BN-LINK Digital Countdown Wall Timer Switch. This device is designed to provide convenient and energy-efficient control over your lights and exhaust fans. With its simple push-button operation and preset countdown options, you can easily automate shut-off times, helping to conserve energy and enhance your daily routine. This manual provides detailed instructions for installation, operation, and safety to ensure optimal performance and longevity of your timer switch.

Apa yang ada dalam Kotak

  • BN-LINK Digital Countdown Wall Timer Switch
  • Plat Dinding
  • Kacang Kawat
  • Skru Pemasangan
  • Manual Arahan
Contents of the BN-LINK Digital Countdown Wall Timer Switch package, including the timer switch, wire nuts, and a wall plate.

Image: Package contents showing the timer switch, wire nuts, and wall plate.

Spesifikasi

ModelBND-60/U110b-1
Mod OperasiHIDUP
Penilaian Semasa15 Amps
Vol Operasitage125 Volt
Jenis KenalanBiasanya Ditutup
Jenis PenyambungClamp
Jenis SuisButang Tekan
Terminalskru
bahanplastik
Dimensi Item (L x W x H)4.2 x 1.8 x 2 inci
Jenis Litar1 hala
Jenis PemasanganLekap di dinding
Jenis PenggerakButang Tekan
Bilangan Jawatan1
Penarafan Suhu Atas122 Darjah Fahrenheit
Kaedah KawalanSentuh
Wattage1875 watt
warnaputih
Penilaian Perlindungan AntarabangsaIP54
PensijilanETL Listed (Conforms to UL Std. 60730-1, 60730-2-7)
Diagram showing the dimensions of the BN-LINK Digital Countdown Wall Timer Switch and its components.

Image: Size details of the timer switch, including its dimensions and included accessories like wire nuts and face plate.

Maklumat Keselamatan Penting

  • AMARAN: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse box and test that the power is off before wiring.
  • Peranti ini memerlukan Kawat Neutral for proper operation. Ensure your electrical box has a neutral wire available.
  • For single-pole installations only. Do not use in 3-way or multi-way switch applications.
  • Rujuk juruelektrik yang berkelayakan jika anda tidak pasti tentang mana-mana bahagian proses pemasangan.
  • Rated 125V, 60 Hz, 15A/1875W Resistive or General Purpose, 10A/1250W Ballast or Tungsten, ½ HP, TV-5. Do not exceed these ratings.

Arahan Pemasangan

  1. Matikan Kuasa: Before beginning any electrical work, ensure the power to the switch location is turned off at the circuit breaker or fuse box. Verify power is off using a voltage penguji.
  2. Keluarkan Suis Sedia Ada: Carefully remove the existing wall plate and switch from the electrical box. Disconnect the wires from the old switch, noting which wire was connected to which terminal.
  3. Kenal pasti wayar: Identify the following wires in your electrical box:
    • Kawat Panas (Talian): Biasanya hitam, membawa kuasa dari pemutus litar.
    • Muatkan Wayar: Typically black, connects to the fan or light fixture.
    • Kawat Neutral: Typically white, required for this timer switch.
    • Wayar bawah tanah: Typically green or bare copper.
  4. Wire the Timer Switch: Connect the wires from your electrical box to the corresponding wires on the BN-LINK timer switch using the provided wire nuts.
    • Sambungkan Kawat Panas from the wall to the Kawat Hitam daripada pemasa.
    • Sambungkan Muatkan Wayar daripada lekapan ke Kawat Merah daripada pemasa.
    • Sambungkan Kawat Neutral from the wall to the Kawat Putih daripada pemasa.
    • Sambungkan Wayar bawah tanah from the wall to the Kawat Hijau daripada pemasa.
  5. Pasang Suis: Carefully push the wired timer switch into the electrical box. Secure it with the provided mounting screws.
  6. Pasang Plat Dinding: Attach the included wall plate over the timer switch.
  7. Pulihkan Kuasa: Hidupkan semula kuasa pada pemutus litar.
Wiring diagram for the BN-LINK Digital Countdown Wall Timer Switch, showing connections for ground, hot, load, and neutral wires.

Image: Detailed wiring diagram for the timer switch, emphasizing the neutral wire requirement.

Video: An instructional video demonstrating the installation and basic operation of the BN-LINK Countdown Digital In-wall Timer Switch.

Arahan Operasi

The BN-LINK Digital Countdown Wall Timer Switch features intuitive push-button controls for easy operation. Each button has a small LED indicator that illuminates when active.

1. Preset Countdown Functions

The timer offers six preset countdown durations: 5 minutes, 15 minutes, 30 minutes, 60 minutes (1 hour), 2 hours, and 4 hours. To activate a countdown:

  • Press the button corresponding to your desired countdown time (e.g., "5 Min", "15 Min", "1 Hour").
  • The LED indicator next to the selected button will illuminate, and the connected device (fan/light) will turn on.
  • The device will automatically turn off once the countdown period expires.

2. Manual ON/OFF

The "ON/OFF" button allows for continuous operation or immediate shut-off, overriding any active countdown or repeat function.

  • Press "ON/OFF" once to turn the connected device on indefinitely. The "ON/OFF" LED will illuminate.
  • Press "ON/OFF" again to turn the connected device off immediately. The "ON/OFF" LED will turn off.

3. Fungsi Ulangan

The "REPEAT" button activates a daily repeat for the currently selected countdown program.

  • While a countdown program is active, press the "REPEAT" button. The "REPEAT" LED will illuminate.
  • The selected countdown will automatically run at the same time every day.
  • To deactivate the repeat function, press the "REPEAT" button again. The LED will turn off.
  • Alternatively, pressing the "ON/OFF" button will also cancel the repeat function.
Close-up of the BN-LINK Digital Countdown Wall Timer Switch buttons, highlighting LED indicators, simple programming, repeat, and on/off functions.

Imej: Selesaiview of timer switch features, including LED indicators, one-button programming, repeat function, and manual ON/OFF.

Image showing the repeat function button on the BN-LINK Digital Countdown Wall Timer Switch, indicating daily automatic operation.

Image: The repeat button on the timer switch, which allows for daily automatic countdowns.

Aplikasi Serbaguna

This timer switch is suitable for a wide range of indoor applications, enhancing convenience and energy savings in various areas of your home. It is compatible with incandescent, fluorescent, and LED lighting, as well as bathroom exhaust fans and heaters.

  • Bilik air: Automatically turn off exhaust fans after a set period to manage humidity.
  • Closets & Pantries: Ensure lights turn off after you leave.
  • Garages & Basements: Prevent lights from being left on accidentally.
  • Bilik Dobi: Control lighting or fan operation.
  • Sauna Rooms: Set specific durations for sauna use.
Collage of various rooms where the BN-LINK Digital Countdown Wall Timer Switch can be used, including bathroom, closet, garage, pantry, sauna room, laundry room, and living room.

Imej: Cthamples of various rooms and settings where the timer switch can be effectively utilized.

Menyelesaikan masalah

If you encounter any issues with your BN-LINK Digital Countdown Wall Timer Switch, please review the installation steps and operating instructions carefully. Ensure all wire connections are secure and that the power supply is active. If problems persist, please contact customer support for assistance.

Waranti dan Sokongan Pelanggan

The BN-LINK Digital Countdown Wall Timer Switch is ETL listed, conforming to UL Std. 60730-1 and 60730-2-7, ensuring safety and reliability. For any questions regarding installation, operation, or product support, please do not hesitate to contact BN-LINK customer service. We are committed to providing quality products and support to our customers.

Contact information can typically be found on the product packaging or the official BN-LINK webtapak.

© 2023 BN-LINK. Hak cipta terpelihara.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.