1. Pengenalan
This manual provides essential information for the safe and efficient operation of your GREISINGER GMH 3531 pH/Redox/Temperature Meter. Please read these instructions carefully before using the device and keep them for future reference. The GMH 3531 is designed for precise measurement of pH, Redox potential, and temperature in various applications.
2. Arahan Keselamatan
- Always operate the device within the specified environmental conditions.
- Jangan dedahkan peranti kepada suhu yang melampau, kelembapan atau cahaya matahari langsung.
- Elakkan daripada menjatuhkan atau meletakkan peranti kepada kesan yang kuat.
- Only use original accessories and probes supplied or approved by GREISINGER.
- Do not attempt to open or repair the device yourself. Refer all servicing to authorized personnel.
- Jauhkan peranti dan aksesorinya daripada kanak-kanak.
- Buang bateri dan peranti mengikut peraturan tempatan.
3. Kandungan Pakej
Selepas membongkar, sila sahkan bahawa semua item yang disenaraikan di bawah ada dan tidak rosak:
- GREISINGER GMH 3531 pH/Redox/Temperature Meter
- Manual Pengendalian
- pH electrode (if included in specific model variant)
- Temperature probe (if included in specific model variant)
- Batteries (installed or separate)

Image: The GREISINGER GMH 3531 pH/Redox/Temperature Meter, showing its compact design and display. This image illustrates the main unit of the device.
4. Persediaan
4.1. Pemasangan Bateri
- Open the battery compartment cover located on the rear of the device.
- Masukkan bateri yang ditentukan, pastikan kekutuban yang betul (+/-).
- Tutup penutup petak bateri dengan selamat.
4.2. Sambungan Probe
- Connect the pH electrode to the designated BNC connector on the device. Ensure a firm connection.
- Connect the temperature probe to its dedicated input jack.
- Ensure all connections are clean and dry before use.
5. Arahan Operasi
5.1. Menghidupkan/Mematikan
Tekan ke HIDUP/MATI button to power on the device. Press and hold the HIDUP/MATI button for approximately 3 seconds to power off.
5.2. Penentukuran
Regular calibration is crucial for accurate measurements. Refer to the specific calibration procedure for pH and Redox measurements outlined below.
5.2.1. Penentukuran pH
- Prepare fresh pH buffer solutions (e.g., pH 4.00, 7.00, 10.00).
- Rinse the pH electrode thoroughly with distilled water and blot dry.
- Immerse the electrode in the first buffer solution (e.g., pH 7.00).
- Enter calibration mode as per the device's menu.
- Follow on-screen prompts to confirm the buffer value.
- Repeat for subsequent buffer solutions.
5.2.2. Redox Calibration
Redox electrodes typically do not require calibration in the same way as pH electrodes. However, their functionality can be checked using a known Redox test solution.
5.3. Mengambil Ukuran
- Ensure the device is calibrated.
- Rinse the probe(s) with distilled water and blot dry.
- Immerse the probe(s) into the sample solution. Ensure the sensing part of the probe is fully submerged.
- Allow the reading to stabilize on the display.
- Record the measurement.
- After measurement, rinse the probe(s) thoroughly and store according to maintenance guidelines.
6. Penyelenggaraan
6.1. Membersihkan Peranti
Wipe the device housing with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure no liquid enters the device openings.
6.2. Probe Care and Storage
- Elektrod pH: Always keep the pH electrode wet. Store it in a suitable storage solution (e.g., 3M KCl solution or pH 4 buffer). Never store in distilled water.
- Elektrod Redoks: Store in a suitable storage solution or distilled water if not used for extended periods.
- Probe Suhu: Clean with distilled water after each use.
- Regularly inspect probes for damage or contamination.
6.3. Penggantian Bateri
Gantikan bateri apabila penunjuk bateri rendah muncul pada paparan. Rujuk bahagian 4.1 untuk arahan pemasangan bateri.
7. Penyelesaian masalah
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Tiada paparan/Peranti tidak akan dihidupkan | Bateri mati atau tidak dipasang dengan betul | Periksa kekutuban bateri; menggantikan bateri. |
| Bacaan tidak stabil | Dirty or damaged probe; insufficient immersion; air bubbles; incorrect calibration | Clean probe; ensure proper immersion; remove air bubbles; recalibrate. |
| Incorrect pH readings | Expired buffer solutions; dirty/damaged pH electrode; incorrect calibration | Use fresh buffer solutions; clean/replace electrode; recalibrate. |
| Mesej "Ralat" dipaparkan | Probe fault; internal device error | Check probe connection and condition. If error persists, contact support. |
8. Spesifikasi
| Parameter | Nilai |
|---|---|
| Model | GMH 3531 (603925) |
| Measurement Range pH | Typically 0.00 to 14.00 pH |
| Measurement Range Redox | Typically -1999 to +1999 mV |
| Measurement Range Temperature | Typically -5.0 to +100.0 °C |
| Ketepatan pH | ±0.02 pH (depending on probe) |
| Suhu Ketepatan | ±0.2 °C (depending on probe) |
| Bekalan Kuasa | Battery operated (e.g., 9V block battery or AA batteries) |
| Berat badan | 170 Grams (without probes) |
Note: Specific ranges and accuracies may vary slightly based on the exact probe used and environmental conditions. Refer to your probe's documentation for detailed specifications.
9. Waranti dan Sokongan
9.1. Maklumat Waranti
GREISINGER products are manufactured to high quality standards. This device comes with a standard manufacturer's warranty against defects in materials and workmanship. The warranty period typically begins from the date of purchase. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, please refer to the official GREISINGER webtapak atau hubungi pengedar tempatan anda.
9.2. Sokongan Teknikal
Should you encounter any issues not covered in the troubleshooting section, or require further assistance, please contact GREISINGER technical support or your authorized dealer. Provide your model number (GMH 3531) and a detailed description of the problem when seeking support.
GREISINGER Contact Information:
Official GREISINGER Webtapak