VAXCEL T0165

VAXCEL Melbourne 1L LED Dusk to Dawn Outdoor Post Light

Model T0165 Instruction Manual

1. Maklumat Keselamatan Penting

Please read and understand all instructions before beginning installation. Failure to do so may result in electric shock, fire, or other injuries that could be hazardous or fatal. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.

  • AMARAN: Risiko renjatan elektrik. Putuskan sambungan kuasa pada fius atau pemutus litar sebelum memasang atau menservis.
  • Semua sambungan elektrik mestilah mengikut kod tempatan, ordinan atau Kod Elektrik Kebangsaan (NEC).
  • Rujuk juruelektrik bertauliah jika anda tidak pasti tentang prosedur pendawaian.
  • This fixture is designed for outdoor, wet location use. Ensure all connections are properly sealed to prevent water intrusion.
  • Jangan cuba mengubah suai sumber cahaya LED bersepadu. Ia tidak boleh diganti.

2. Kandungan Pakej

Sahkan bahawa semua komponen hadir sebelum memulakan pemasangan:

  • 1 x VAXCEL Melbourne Post Light Fixture (with integrated LED)
  • 1 x Clear Crackle Glass Shade
  • Perkakasan Pemasangan (skru, nat dawai)

3. Spesifikasi

CiriSpesifikasi
Nombor ModelT0165
Dimensi (L x W x H)8" x 8" x 16"
Berat badan3.97 paun
bahanKeluli Aloi, Kaca
Sumber CahayaIntegrated LED (6 Watts)
Kecerahan300 Lumen
Suhu Warna3000 Kelvin (Putih Hangat)
Indeks Paparan Warna (CRI)82
Voltage120 Volt
Ciri KhasDusk to Dawn Sensor, Exterior Wet Rated
Jenis PemasanganPost Mounted (fits standard 3-inch diameter post, not included)
Diagram showing the dimensions of the VAXCEL Melbourne post light. Height (A) is 16 inches, Width (B) is 8 inches.
Figure 1: Product Dimensions. The fixture measures 8 inches in width and 16 inches in height.

4. Arahan Pemasangan (Persediaan)

Before you begin, ensure the power is turned off at the circuit breaker. This fixture is designed to be mounted on a standard 3-inch diameter post (post not included).

  1. Prepare the Post: Ensure your existing 3-inch diameter post is securely installed and has electrical wiring extending from its top.
  2. Sambungan Pendawaian: Carefully connect the fixture's wires to your household electrical wires. Use the provided wire nuts to secure connections:
    • Connect the black wire from the fixture to the black (hot) wire from the post.
    • Connect the white wire from the fixture to the white (neutral) wire from the post.
    • Connect the green or bare copper ground wire from the fixture to the green or bare copper ground wire from the post.
    Pastikan semua sambungan adalah ketat dan selamat.
  3. Pasang Lekapan: Carefully place the fixture onto the top of the 3-inch post, aligning any pre-drilled holes if applicable. Secure the fixture to the post using the provided mounting screws. Do not overtighten.
  4. Pasang Teduhan Kaca: Gently place the clear crackle glass shade into the fixture, ensuring it is seated properly and securely.
  5. Pulihkan Kuasa: Setelah lekapan dipasang dengan selamat dan semua sambungan dibuat, kembalikan kuasa pada pemutus litar.
VAXCEL Melbourne post light installed on a black outdoor post in a garden setting, with a house in the background.
Figure 2: VAXCEL Melbourne Post Light installed on an outdoor post.
Close-up of the VAXCEL Melbourne post light showing the small circular photocell sensor on the base of the fixture.
Figure 3: Photocell for Dusk to Dawn feature, located on the base of the fixture.

5. Arahan Operasi

The VAXCEL Melbourne Post Light features an integrated dusk-to-dawn photocell sensor for automatic operation. There are no manual controls for this light fixture.

  • Hidup/Mati Automatik: The photocell sensor (refer to Figure 3) detects ambient light levels. The fixture will automatically turn on when it gets dark and turn off when it detects sufficient daylight.
  • Operasi Awal: Upon initial power-up, the light may take a few minutes to calibrate or may turn on briefly before turning off if it is daytime. This is normal operation.

6. Penyelenggaraan

Regular maintenance will help preserve the appearance and functionality of your VAXCEL Melbourne Post Light.

  • Pembersihan: Untuk membersihkan lekapan, pastikan kuasa dimatikan. Lap dengan kain lembutamp kain. Jangan gunakan pembersih atau pelarut yang melelas, kerana ia boleh merosakkan kemasan atau kaca.
  • Sumber Lampu LED: The LED light source is integrated and designed for long-lasting performance. It is not user-replaceable.
  • Photocell: Keep the photocell sensor (Figure 3) free from dirt, debris, or obstructions (e.g., leaves, snow) to ensure proper dusk-to-dawn operation.

7. Penyelesaian masalah

If your VAXCEL Melbourne Post Light is not functioning as expected, refer to the following common issues and solutions:

MasalahKemungkinan PuncaPenyelesaian
Lampu tidak menyala pada waktu malam.Tidak ada kekuatan untuk perlawanan.
Photocell is obstructed or faulty.
Isu pendawaian.
Check circuit breaker and wall switch (if applicable).
Ensure photocell is clean and not blocked by objects.
Verify wiring connections are secure (with power off).
Cahaya kekal menyala pada siang hari.Photocell is obstructed or faulty.
Insufficient ambient light reaching the sensor.
Ensure photocell is clean and not blocked.
Relocate the fixture if it's in a shaded area during the day.
Cahaya berkelip atau malap.Sambungan pendawaian longgar.
Turun naik kuasa.
Check all wiring connections (with power off).
Consult an electrician if power fluctuations are suspected.

If these steps do not resolve the issue, please contact VAXCEL customer support.

8. Maklumat Waranti

The VAXCEL Melbourne 1L LED Dusk to Dawn Outdoor Post Light (Model T0165) is covered by a Waranti terhad 5 tahun from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For full warranty terms and conditions, please refer to the VAXCEL official webtapak atau hubungi sokongan pelanggan.

9. Maklumat Hubungan

For further assistance, technical support, or warranty claims, please contact VAXCEL customer service:

© 2026 VAXCEL. All rights reserved. Specifications are subject to change without notice.

Dokumen Berkaitan - T0165

Praview Vaxcel T0323 Melbourne LED Outdoor Motion Sensor Light - Assembly and Installation Instructions
Comprehensive assembly and installation guide for the Vaxcel T0323 Melbourne LED outdoor motion sensor light. Includes features, operation modes, customization, troubleshooting, and warranty information.
Praview Arahan Pemasangan dan Pemasangan Vaxcel T0739
Dokumen ini menyediakan arahan pemasangan dan pemasangan untuk lekapan Vaxcel T0739. Ia termasuk senarai pakej perkakasan, panduan pemasangan langkah demi langkah, arahan pemutusan sambungan fotosel pilihan dan maklumat waranti.
Praview Vaxcel T0653 Outdoor Light Fixture Assembly and Installation Instructions
Step-by-step assembly and installation instructions for the Vaxcel T0653 outdoor light fixture, including wiring, optional photocell disconnection, and spare parts list.
Praview Arahan Pemasangan dan Pemasangan Vaxcel T0571
Arahan pemasangan dan pemasangan terperinci untuk lekapan lampu luar Vaxcel T0571, termasuk senarai perkakasan, gambar rajah pendawaian dan maklumat waranti.
Praview Vaxcel T0804/T0805 Motion Sensor Sconce Dinding Luaran: Panduan Pemasangan dan Pemasangan
Arahan pemasangan dan pemasangan yang komprehensif untuk sconce dinding luar penderia gerakan Vaxcel T0804 dan T0805. Ketahui cara memasang, mengendalikan dan menyelesaikan masalah lekapan anda.
Praview Vaxcel T0199 / T0200 Outdoor Wall Lantern Installation Instructions
Installation and assembly guide for Vaxcel T0199 and T0200 outdoor wall lanterns. Includes wiring instructions, photocell operation, and warranty details.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.