1. Pengenalan
The APC Back-UPS BX1400UI is an Uninterruptible Power Supply (UPS) designed to protect your electronic equipment from power outages, surges, and spikes. Featuring Line Interactive Technology and Automatic Voltage Regulation (AVR), this unit provides reliable battery backup and surge protection for connected devices. It includes six IEC 320 C13 outlets, a USB interface for communication, and data line protection.

Rajah 1: Depan view of the APC Back-UPS BX1400UI.
2. Maklumat Keselamatan Penting
- Bahaya Elektrik: Unit ini mengandungi vol tinggitage components. Do not attempt to open the UPS casing, especially when connected to power. Refer all servicing to qualified personnel.
- Sambungan Terus: Always connect the UPS directly to a wall outlet. Do not use surge protectors, extension cords, or power strips with the UPS input.
- Pengudaraan: Pastikan pengudaraan yang mencukupi di sekitar UPS. Jangan halang bukaan pengudaraan.
- Bau Awal: A new unit may emit a distinct odor, often described as similar to burnt plastic. This is normal and typically dissipates after a few weeks of continuous operation in a well-ventilated area. It is not indicative of a malfunction.
- Penggantian Bateri: User-performed battery replacement during the warranty period will void the product warranty. Refer to the Maintenance section for details.
3. Kandungan Pakej
Sahkan bahawa pakej anda mengandungi item berikut:
- APC Back-UPS BX1400UI Unit
- Two (2) IEC-C13 to IEC-C14 power cables (for connecting devices to the UPS)
- Manual Pengguna (dokumen ini)
Nota: The input power cable (for connecting the UPS to the wall outlet) and the USB communication cable are typically tidak termasuk and must be purchased separately if needed.
4. Persediaan
4.1. Unpacking and Battery Connection
- Keluarkan UPS dari pembungkusannya dengan berhati-hati.
- Locate the yellow battery connector on the rear panel of the UPS. This connector is typically disconnected for safe transport.
- Push the yellow battery connector firmly into its socket until it clicks into place. This activates the UPS battery circuits.
4.2. Menyambung kepada Kuasa
- Connect the UPS to a grounded 230V AC wall outlet using an appropriate IEC-320 C14 input power cable (not included).
- Ensure the connection is direct to the wall outlet. Do not use surge protectors or extension cords.
- Allow the UPS to charge for at least 10 hours before connecting critical equipment to ensure full battery runtime.
4.3. Peralatan Penyambung
The BX1400UI features six IEC 320 C13 outlets for connecting your devices.
- Saluran Perlindungan Sandaran & Lonjakan Bateri: All six IEC-C13 outlets provide both battery backup and surge protection. Connect your computer, monitor, and other critical electronics to these outlets.
- Perlindungan Talian Data: The rear panel includes RJ-11 ports labeled "DSL/Modem/Fax/Phone" for protecting your telephone or DSL line from surges. These ports are not suitable for Ethernet network connections.
- Antaramuka USB: Connect a USB Type B cable (not included) from the UPS to your computer for communication and to enable shutdown software functionality.

Figure 2: Rear panel connections of the APC Back-UPS BX1400UI.
5. Arahan Operasi
5.1. Menghidupkan/Mematikan
- Untuk Menghidupkan: Press and hold the power button on the front panel until you hear a short beep. The UPS will perform a self-test, and the 'On Line' LED will illuminate green.
- Untuk Mematikan: Tekan dan tahan butang kuasa sehingga UPS dimatikan.
5.2. Petunjuk LED
The front panel features LED indicators to show the UPS status:
- Dalam Talian (LED Hijau): Indicates the UPS is operating on utility power and providing power to connected equipment.
- Pada Bateri (LED Kuning): Indicates the UPS is operating on battery power during a power outage or brownout. A humming noise is normal during battery operation.
- Ganti Bateri (LED Merah): Indicates the battery needs to be replaced.
- Beban Lebih (LED Merah): Indicates that the connected equipment exceeds the UPS's capacity. Disconnect non-essential equipment immediately.
5.3. Automatik Voltage Peraturan (AVR)
UPS membetulkan volum kecil secara automatiktage fluctuations (sags and surges) without switching to battery power, thus preserving battery life. If voltage fluctuations exceed the AVR's correction range, the UPS will switch to battery power.
6. Ciri-ciri Utama
- Teknologi Interaktif Talian: Provides stable power by regulating voltage without constantly switching to battery.
- Vol. Automatiktage Peraturan (AVR): Corrects minor voltagturun naik tanpa menggunakan kuasa bateri.
- Bateri tambahan: Supplies power to connected equipment during outages.
- Perlindungan lonjakan: Protects connected devices from damaging power surges and spikes.
- 6 IEC 320 C13 Outlets: Standard outlets for computer equipment.
- Antaramuka USB: Enables communication with a computer for monitoring and controlled shutdown.
- Perlindungan Talian Data: Safeguards telephone/DSL lines from surges.
7. Penggunaan Perisian
The APC Back-UPS BX1400UI supports USB Human Interface Device (HID) class specifications, allowing it to be recognized by most operating systems without special drivers.
7.1. APC PowerChute Personal Edition (Windows)
For advanced monitoring and management on Windows systems, download the APC PowerChute Personal Edition software from the official APC webtapak. Perisian ini membolehkan anda untuk:
- Monitor UPS status, power consumption, and battery charge.
- Konfigurasikan penutupan automatik komputer anda semasa pemadaman kuasa yang berpanjangantages.
- Adjust UPS settings, such as alarm behavior (e.g., disable the beeper during battery operation).
- Perform self-tests to ensure proper UPS functionality.
7.2. Linux Support (apcupsd / NUT)
For Linux environments, the UPS can be managed using `apcupsd` or Network UPS Tools (NUT). These tools provide similar monitoring and shutdown capabilities. Refer to the documentation for `apcupsd` or NUT for configuration details, typically involving specifying `UPSCABLE usb` and `UPSTYPE usb` for `apcupsd`, or using the `usbhid-ups` driver for NUT.
8. Penyelenggaraan
8.1. Penggantian Bateri
The APC Back-UPS BX1400UI uses two 12V 7.2Ah sealed lead-acid batteries. The recommended replacement battery pack is APC RBC113.
- During Warranty: If the unit is still under its 2-year warranty, battery replacement must be performed by Schneider Electric IT (SEIT) customer service. User-performed battery replacement during the warranty period will automatically void the warranty.
- After Warranty: After the warranty period, batteries can be replaced by the user. However, due to the presence of high voltage components even when disconnected, it is highly recommended that this operation be performed by specialized personnel. If you choose to replace the batteries yourself, exercise extreme caution.
- Selesai Prosedurview (for experienced users only): Disconnect the UPS from all power sources and connected equipment. Disconnect the yellow battery connector. Remove the rear panel screws, then the front panel (which is snap-fitted), and additional screws. Carefully access the battery compartment. Note the orientation and wiring of the existing batteries (taking photos is recommended) to ensure correct installation of the new batteries.
8.2. Set Semula Pemutus Litar
In case of an overload, the UPS may trip its circuit breaker. To reset, disconnect some equipment from the UPS, then press the circuit breaker button located on the rear panel (refer to Figure 2).
9. Penyelesaian masalah
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| UPS tidak dihidupkan. | Battery connector disconnected; No input power. | Ensure yellow battery connector is fully inserted. Verify UPS is plugged into a live wall outlet. |
| Initial strong odor. | New unit manufacturing residue. | This is normal. Ensure adequate ventilation. Odor will dissipate over time (typically a few weeks). |
| UPS emits a humming noise. | Operating on battery power; Normal electrical noise. | Humming is normal when on battery. If persistent and loud on utility power, ensure proper ventilation and check for loose connections. |
| 'Overload' LED is lit. | Terlalu banyak peralatan yang disambungkan. | Disconnect non-essential equipment. Press the circuit breaker reset button on the rear panel. |
| 'Replace Battery' LED is lit. | Bateri hampir tamat hayat. | Contact APC support or a qualified technician for battery replacement. Refer to Section 8.1. |
| Masa jalan bateri pendek. | Battery not fully charged; Battery nearing end of life; Excessive load. | Ensure initial 10-hour charge. Reduce connected load. Consider battery replacement if old. |
For more detailed troubleshooting, refer to the complete user manual available on the APC webtapak.
10. Spesifikasi
| Ciri | Spesifikasi |
|---|---|
| Model | BX1400UI |
| Kapasiti (VA/Watts) | 1400 VA / 700 W |
| Input Voltage | 230V AC |
| Kekerapan Input | 50 Hz |
| Keluaran Voltage | 230V AC (simulated sine wave on battery) |
| Saluran Keluaran | 6 x IEC 320 C13 (Battery Backup & Surge Protection) |
| Penilaian Perlindungan Lonjakan | 273 Joule |
| Jenis Bateri | Asid Plumbum Tertutup |
| Konfigurasi Bateri | 2 x 12V 7.2Ah |
| Masa Caj Semula Biasa | 8 jam (sehingga 90% kapasiti) |
| Runtime (at 700W load) | Lebih kurang 1 minit |
| Runtime (at 100W load) | Lebih kurang 60 minit |
| Dimensi (H x W x D) | 21.5 cm x 13 cm x 33.6 cm |
| Berat badan | 4.7 kg |
| Pelabuhan Antara Muka | USB Type B, RJ-11 (Data Line Protection) |

Figure 3: Typical runtime graph for APC Back-UPS 1400VA.
11. Waranti dan Sokongan
11.1. Jaminan Produk
The APC Back-UPS BX1400UI comes with a Waranti terhad 2 tahun dari tarikh pembelian. Waranti ini melindungi kecacatan pada bahan dan mutu kerja di bawah penggunaan biasa. Sila simpan bukti pembelian anda untuk tuntutan waranti.
Penting: Unauthorized opening of the unit or user-performed battery replacement during the warranty period will void the warranty.
11.2. Sokongan Teknikal
For technical assistance, troubleshooting, or warranty service, please contact APC by Schneider Electric customer support. Visit the official APC website for contact information specific to your region, including phone numbers and online support resources.
Online resources often include FAQs, knowledge bases, and downloadable manuals that can provide further assistance.